DATA_QUALITY_ID_DESC.TXT ===================== V02 - 19/07/07 C. NEHME updapted for SPICAV V01 - 12/07/07 A. Reberac original for SPICAM This file describes the data quality which is associated with a particular DATA_QUALITY_ID value. Data Quality Flag ================= Each data file label includes a quality flag string in the DATA_QUALITY_ID keyword. The eight characters of this field are described below. Definition - Data Quality Index c0 = Data Quality Flag (0=good,1=flagged for quality defects, 2=not yet qualified) c1 to c7 are different quality defects observed in SPICAV data. Each of these characters is set to 1 if the observation is concerned by the associated quality defect (see definition of each character), or to 0 if not concerned. c1 = data are partly satured c2 = data are affected by stray light (light from the limb, light from another source than the main target, or instrument effect (i.e: light from the wild slit)). c3 = NOT USED for SPICAV c4 = data are affected by oscillations. c5 = bad pointing, satellite manoeuvre not expected during the observation, or shift of the star spectrum along the wavelength axis. c6 = target missed or observation incomplete (e.g. stellar occultation observation with star partly or not occulted by the atmosphere of the planet, or only the occulted part of the observation available (no star spectrum). This may be due to a good poiting but : - a wrong timing window. During the planning process, timing window are defined relative to the pericenter. If a change in the orbit occurs (after a safe mode for example,where an orbit correction manoeuvre is performed in order to bring the spacecraft to the nominal free-drift orbit) the relative time of the pericenter can be shifted by some minutes, and therefore the target is no more centred in the timing window. - or a timing window cut during the observation planning process (conflicts with other instrument, problem of data volume, violation of illumination constraints...) c7 = missing packets