INSTRUMENT_MODE_DESC gives an overview of the different operational modes of SOIR Written by Eddy NEEFS SOIR spectra contained within one observation may be taken in either of 3 modes: (1) AOTF frequency hopping : During each observation up to 4 random AOTF frequencies (hopping) and hence non-contiguous small wavelength domains are recorded. (2) Single parameter stepping : During each observation a series of up to 4 wavelength domains is recorded. The parameters defining each of the domains are identical, except one which is incremented by a fixed amount from domain to domain. Can be executed either continuous from one observation to the next or reset to a value specified by TC at each observation. A special case of single parameter stepping is AOTF frequency stepping: the AOTF frequency is incremented by a fixed frequency step for each sequential spectral domain, while all other parameters remain unchanged. (3) Automatic window stepping : The detector is read-out completely by reading sequentially windows of 8 lines. Observations start with the detector window positioned at line 1 and for subsequent observations the window is shifted by 8 lines. In total 32 observations are required to read out the complete detector array.