PDS_VERSION_ID = PDS3 RECORD_TYPE = "STREAM" OBJECT = TEXT PUBLICATION_DATE = 2013-04-30 NOTE = "Description of the CALIB directory" END_OBJECT = TEXT END Description of the CALIB directory at PSA level 2 and 3 4.1 Introduction The CALIB directory contains 4 calibration files available in the PDS3 format: - The resolution calibration file - The AOTF frequency to wavenumber calibration file - The AOTF transfer function calibration file - The Blaze function calibration file. Each file is accompanied with a CAT file, in the PDS3 format. 4.2 Resolution calibration file The resolution calibration data are given in the RESOL_BINNINGXX.TAB files. The different binning XX possibilities are listed in Table 1. This file is made of (bins+1) columns, where bins corresponds to the value listed in the second columnof Table 1. Binning case Number of lines per bin Number of binning groups 8 x 3 3 8 8 x 4 4 8 2 x 12 12 2 2 x 16 16 2 Table 1: List of the binning possibilities 4.3 The AOTF frequency to wavenumber calibration file The AOTF frequency to wavenumber calibrations are given in the AOTF_F_WN.TAB with its associated LBL file. This file is made of 6 columns, the first one giving the relation type (AOTF frequency to wavenumber F->WN or wavenumber to AOTF frequency WN->F). The relations are defined in Section 2.3. The second column gives the binning case and the third one the bin number. Table 1 summarizes the detector lines that are summed up for each case and Table 1 gives the different binning cases. The three last columns give the values of the second order polynomial coefficients. There is one calibration file for the nominal mission, and for each extension of the mission. 4.4 The AOTF transfer function calibration file The AOTF transfer function values are given in the AOTF_TF_BINNINGXX.TAB with its associated LBL file. As for the resolution, there is a file for each binning case, which are listed in Table 1. The first column gives the diffraction order number, followed by the centered wavenumber values (between -100 and 100 cm-1 around the maximum, by steps of 0.1cm-1, 2001 in total), the transfer function values for bin 1 (2001 in total) and the transfer function values for bin 2 (2001 in total). There is one line per order (94 in total). 4.5 The blaze function calibration file The blaze function values are given in the BLAZE.TAB with its associated LBL file. The first column gives the diffraction order number, followed by the centered wavenumber values (between -100 and 100 cm-1 around the center of the order, by steps of 0.1cm-1, 2001 in total) and the blaze function values (2001 in total), same for bins 1 and 2. There is one line per order (94 in total).