OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 UNIT = "N/A" DESCRIPTION = "This COLUMN represents the UTC at the start of the data matrix in PDS standard format YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "OBT" DATA_TYPE = CHARACTER START_BYTE = 26 BYTES = 19 UNIT = "N/A" DESCRIPTION = "Spectrum On board Time : OBT is represented as : Reset number (integer starting at 1) / seconds. Reset number 1 starts at 2005-11-09T03:33:00 UTC The time resolution is 1/65536 s " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "SW_VERSION" DATA_TYPE = ASCII_INTEGER START_BYTE = 47 BYTES = 5 UNIT = "N/A" FORMAT = "I5" DESCRIPTION = "Software version" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "SECTOR_MASK" DATA_TYPE = CHARACTER START_BYTE = 54 BYTES = 16 UNIT = "N/A" DESCRIPTION = "ELS Sector mask defines the active sectors that are set for the measurement. The Binary format is used. One bit (or character) represents the status of one ELS sector and may take one of the following values bit 0 (sector 0): 1 (enable), 0 (disable) bit 1 (sector 1): 1 (enable), 0 (disable) bit 2 (sector 2): 1 (enable), 0 (disable) bit 3 (sector 3): 1 (enable), 0 (disable) bit 4 (sector 4): 1 (enable), 0 (disable) bit 5 (sector 5): 1 (enable), 0 (disable) bit 6 (sector 6): 1 (enable), 0 (disable) bit 7 (sector 7): 1 (enable), 0 (disable) bit 8 (sector 8): 1 (enable), 0 (disable) bit 9 (sector 9): 1 (enable), 0 (disable) bit 10 (sector 10): 1 (enable), 0 (disable) bit 11 (sector 11): 1 (enable), 0 (disable) bit 12 (sector 12): 1 (enable), 0 (disable) bit 13 (sector 13): 1 (enable), 0 (disable) bit 14 (sector 14): 1 (enable), 0 (disable) bit 15 (sector 15): 1 (enable), 0 (disable)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "TIME_COMPRESSION" DATA_TYPE = ASCII_INTEGER START_BYTE = 72 BYTES = 2 UNIT = "N/A" FORMAT = "I2" DESCRIPTION = "Time compression. The field takes one of the following values: 1 (sweep) 2 (sweeps) 4 (sweeps) 8 (sweeps) 16 (sweeps) -1 (for undefined)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "ENERGY_COMPRESSION" DATA_TYPE = ASCII_INTEGER START_BYTE = 75 BYTES = 2 UNIT = "N/A" FORMAT = "I2" DESCRIPTION = "Energy compression value indicates how many energy steps have been summed over. 128 divided by this value gives the number of energy steps. The field takes one of the following values: 1 (step) 2 (steps) 4 (steps) -1 (for undefined)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "LOG_COMPRESSION" DATA_TYPE = ASCII_INTEGER START_BYTE = 78 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Log compression" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "RICE_COMPRESSION_FLAG" DATA_TYPE = ASCII_INTEGER START_BYTE = 80 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Rice compression flag status. The field takes one of the following values: 0 = non valid 1 = valid" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "RICE_COMPRESSION_VALUE" DATA_TYPE = ASCII_INTEGER START_BYTE = 82 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Rice compression" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = "SCANNER_DIRECTION" DATA_TYPE = ASCII_INTEGER START_BYTE = 84 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Scanner direction. The field takes one of the following values: 0: 0 - 180 1: 180 - 0" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = "SCANNER_SPEED" DATA_TYPE = ASCII_INTEGER START_BYTE = 86 BYTES = 3 UNIT = SECOND FORMAT = "I3" DESCRIPTION = "Scanner speed. This is not the actual moving speed at the specified time, but a setting speed value that is applied in operation to the scanner once a command is sent to move it. The field takes one of the following values: 0 (standing) 32 (seconds scan) 64 (seconds scan) 128 (seconds scan)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "SCANNER_POSITION" DATA_TYPE = ASCII_REAL START_BYTE = 90 BYTES = 5 UNIT = "DEGREE" FORMAT = "F5.1" DESCRIPTION = "Scanner position in degrees" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "ELS_STATUS" DATA_TYPE = ASCII_INTEGER START_BYTE = 96 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "ELS Status" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "ELS_TEMPERATURE" DATA_TYPE = ASCII_REAL START_BYTE = 100 BYTES = 7 UNIT = "CELSIUS" FORMAT = "F7.2" DESCRIPTION = "ELS temperature in degree Celsius " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "ELS_MCP_REFERENCE" DATA_TYPE = ASCII_INTEGER START_BYTE = 108 BYTES = 3 UNIT = "ADC_UNITS" FORMAT = "I3" DESCRIPTION = "Uncalibrated ELS MCP reference" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "ELS_MCP_MONITOR" DATA_TYPE = ASCII_REAL START_BYTE = 112 BYTES = 7 UNIT = "VOLT" FORMAT = "F7.2" DESCRIPTION = "ELS MCP bias monitor in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "ELS_SCREEN_GRID_REFERENCE" DATA_TYPE = ASCII_INTEGER START_BYTE = 120 BYTES = 3 UNIT = "ADC_UNITS" FORMAT = "I3" DESCRIPTION = "Uncalibrated ELS screen grid reference" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "ELS_SCREEN_GRID_MONITOR" DATA_TYPE = ASCII_REAL START_BYTE = 124 BYTES = 6 UNIT = "VOLT" FORMAT = "F6.3" DESCRIPTION = "ELS screen grid bias monitor in Volts" END_OBJECT = COLUMN