OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "JOB_ID" DATA_TYPE = CHARACTER START_BYTE = 9 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Jobcard identifier (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SAVE_FULL" DATA_TYPE = ASCII_INTEGER START_BYTE = 13 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Possible values : 0 : Save ID Only 1 : Save Full" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MORE_JOBS" DATA_TYPE = ASCII_INTEGER START_BYTE = 15 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Possible values : 0 : Last Job 1 : More Jobs" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SUB_ID" DATA_TYPE = CHARACTER START_BYTE = 18 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Hex value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "START_CONDITION" DATA_TYPE = CHARACTER START_BYTE = 23 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Hex value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "REPETITIONS" DATA_TYPE = ASCII_INTEGER START_BYTE = 27 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = " Number of repetitions" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOUND_FREQ" DATA_TYPE = ASCII_INTEGER START_BYTE = 31 BYTES = 5 FORMAT = "I5" UNIT = "HERTZ" DESCRIPTION = " transmitter sound frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SND_DURATION" DATA_TYPE = ASCII_REAL START_BYTE = 37 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" MISSING_CONSTANT = 9999999.9 DESCRIPTION = "Sounding duration in sounding mode" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_TIMEOUT" DATA_TYPE = ASCII_INTEGER START_BYTE = 47 BYTES = 5 FORMAT = "I5" UNIT = "SECOND" MISSING_CONSTANT = 99999 DESCRIPTION = "Time-out duration, after which listening stops if no trigger signal occured" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SAMPLING_FREQ" DATA_TYPE = ASCII_INTEGER START_BYTE = 53 BYTES = 6 FORMAT = "I6" UNIT = "HERTZ" DESCRIPTION = "Sampling frequency per channel" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TX_STATUS" DATA_TYPE = CHARACTER START_BYTE = 61 BYTES = 5 FORMAT = "A5" UNIT = "N/A" DESCRIPTION = "Selection of transmitters to be used in Sounding Mode. If TX_cycle is set, after a measurement the transmitter selection is (cyclically) shifted by one position up to yield the transmitters to be used for the next measurement. If Tx_reverse is additionally set, the selection of active transmitters is shifted one position downwards instead. Bit field represented as 5 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #4. Each character can be 1 (active sensor or cycle on or reversed on) or 0 (sensor not used) and have the following meaning. bit 0: TRM -Y bit 1: TRM +X bit 2: TRM +Y bit 3: TX_cycle bit 4: TX_reverse " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AGC" DATA_TYPE = CHARACTER START_BYTE = 69 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Amplification gain selection in hexadecimal format Value to be written to the Amplifier Gain Control register of CASSE electronics. Decimal value ranges from 0 (maximal gain) to 15 (minimal gain). Note (a) the gain is not a monotone function of the AGC value, (b) the actually adjusted gain can deviate, if automatic gain setting (AGS) is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_SRC" DATA_TYPE = CHARACTER START_BYTE = 74 BYTES = 13 FORMAT = "A13" UNIT = "N/A" DESCRIPTION = "Subset of active sensor channels used as trigger sources. Bit field represented as 12 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #11. Each character can be 1 (active sensor used as a trigger source) or 0 (sensor not used as a trigger source) and have the following meaning. bit 0: ACC -Y, x-axis bit 1: ACC -Y, y-axis bit 2: ACC -Y, z-axis bit 3: ACC +X, x-axis bit 4: ACC +X, y-axis bit 5: ACC +X, z-axis bit 6: ACC +Y, x-axis bit 7: ACC +Y, y-axis bit 8: ACC +Y, z-axis bit 9: TRM -Y bit 10: TRM +X bit 11: TRM +Y bit 12: AUTO RANGE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_DELAY" DATA_TYPE = ASCII_REAL START_BYTE = 89 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" DESCRIPTION = " Determines the time range before (negative value) or after (positive value) a trigger event, which shall be included in the time series. Absolute value of TrgDelay must be less or equal LIS_DURATION." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_LEVEL_POS" DATA_TYPE = ASCII_INTEGER START_BYTE = 99 BYTES = 4 FORMAT = "I4" UNIT = "N/A" DESCRIPTION = "Positive trigger level. Value to be written to the UTT hardware register, which fixes the upper (always positive) trigger threshold. Note that the actually adjusted value can be different, if automatic trigger level setting is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_LEVEL_NEG" DATA_TYPE = ASCII_INTEGER START_BYTE = 104 BYTES = 4 FORMAT = "I4" UNIT = "N/A" DESCRIPTION = "Negative trigger level. Value to be written to the LTT hardware register, which fixes the lower (always negative) trigger threshold. Note that the actually adjusted value can be different, if automatic trigger level setting is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RX_DURATION" DATA_TYPE = ASCII_REAL START_BYTE = 109 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" DESCRIPTION = "Measurement duration " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RX_STATUS" DATA_TYPE = CHARACTER START_BYTE = 120 BYTES = 16 FORMAT = "A16" UNIT = "N/A" DESCRIPTION = "Selection of sensor channels to be used. If cycle is set, after a measurement the receiver selection is (cyclically) shifted by one position (in the same direction as the transmitters, as indicated in TX_STATUS. If the reversed flag is additionally set, the receiver cycling shall take place in the opposite direction as the transmitter cycling. Bit field represented as 15 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #13. Each character can be 1 (active sensor or cycle on or reversed on) or 0 (sensor not used) and have the following meaning. bit 0: ACC -Y, x-axis bit 1: ACC -Y, y-axis bit 2: ACC -Y, z-axis bit 3: ACC +X, x-axis bit 4: ACC +X, y-axis bit 5: ACC +X, z-axis bit 6: ACC +Y, x-axis bit 7: ACC +Y, y-axis bit 8: ACC +Y, z-axis bit 9: TRM -Y bit 10: TRM +X bit 11: TRM +Y bit 12: cycle bit 13: sort bit 14 : reversed bit 15 : custom seq " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GPW1" DATA_TYPE = CHARACTER START_BYTE = 139 BYTES = 16 FORMAT = "A16" UNIT = "N/A" DESCRIPTION = "General Purpose Word 1, binary" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GPW2" DATA_TYPE = CHARACTER START_BYTE = 158 BYTES = 16 FORMAT = "A16" UNIT = "N/A" DESCRIPTION = "General Purpose Word 2, binary" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GPW3" DATA_TYPE = CHARACTER START_BYTE = 177 BYTES = 16 FORMAT = "A16" UNIT = "N/A" DESCRIPTION = "General Purpose Word 3, in binary" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FOOT_TEMP" DATA_TYPE = CHARACTER START_BYTE = 196 BYTES = 8 FORMAT = "A8" UNIT = "N/A" DESCRIPTION = "Active foot temperature channels. Bit field represented as 15 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #6. The Temperature and Radiation Dose Data Block will be generated by flight software, if at least one foot temperature channel is selected in FOOT_TEMP. It will additionally be included at the end of a measuring sequence, if the Additional after job flag is set. Each character can be 1 (channel selected) or 0 (channel not selected) and have the following meaning. bit 0: Temperature -Y, TRM bit 1: Temperature -Y, ACC bit 2: Temperature +X, TRM bit 3: Temperature +X, ACC bit 4: Temperature +Y, TRM bit 5: Temperature +Y, ACC bit 6: Additional after job temperatures bit 7 : Do additional housekeeping" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OUTBUFFER_PAGE" DATA_TYPE = CHARACTER START_BYTE = 207 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "hex value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OUTBUFFER_ADDRESS" DATA_TYPE = CHARACTER START_BYTE = 212 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = " hex value" END_OBJECT = COLUMN