OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MEAS_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 8 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Measurement index, i.e. the number of the measurement in the file. Starts from 1." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 15 BYTES = 23 DESCRIPTION = "This column represents the UTC Time for start of the sequence" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 39 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Start time of measurement. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ERROR_INIT" DATA_TYPE = CHARACTER START_BYTE = 56 BYTES = 4 FORMAT = "A4" DESCRIPTION = "Error status after initialisation in hexadecimal format (2 bytes). Possible values: 0001 EB_FREQ Invalid frequency increment (adjustment of sampling frequency); default (= 1312) used. 0002 EB_DIVRAT Invalid frequency divider (adjustment of sounding frequency); default (= 1) used. 0004 EB_CDPU_ADC Error during temperature A/D conversion. 4008 EB_NCHAN Fatal: Invalid number of sensor channels 4010 EB_TIMEO Fatal: Time-out during triggered mode. 4020 EB_NOSTRT Fatal: Measurement start condition not fulfilled. 8040 EB_RAMOVR Fatal: Allocated SESAME SRAM space exhausted. 4000 EB_FATAL_MES Fatal error or time-out; current measurement will be aborted. Columns are filled by missing_constant if the last case occurs (4000), for the concerned mesurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_DIVIDER" DATA_TYPE = ASCII_INTEGER START_BYTE = 62 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Adjusted transmitter frequency register value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_INCREMENT" DATA_TYPE = ASCII_INTEGER START_BYTE = 66 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "Adjusted sampling rate registers value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHANNELS" DATA_TYPE = ASCII_INTEGER START_BYTE = 72 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Number of sensor channels minus one" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_STATUS" DATA_TYPE = ASCII_INTEGER START_BYTE = 76 BYTES = 4 FORMAT = "I4" UNIT = "N/A" MISSING_CONSTANT = 9999 DESCRIPTION = "Contents of Trigger Status Register at time of trigger" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_ON" DATA_TYPE = CHARACTER START_BYTE = 82 BYTES = 15 FORMAT = "A15" MISSING_CONSTANT = 999999999999999 DESCRIPTION = "SESAME Local Time at start of recording of measurement represented as : Reset number (integer starting at 1) / seconds The time resolution is 0.03125 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_TRIGGER" DATA_TYPE = CHARACTER START_BYTE = 100 BYTES = 15 FORMAT = "A15" MISSING_CONSTANT = 999999999999999 DESCRIPTION = "SESAME Local Time when trigger occurred represented as : Reset number (integer starting at 1) / seconds The time resolution is 0.03125 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIME_BURST_OFF" DATA_TYPE = CHARACTER START_BYTE = 118 BYTES = 15 FORMAT = "A15" MISSING_CONSTANT = 999999999999999 DESCRIPTION = "SESAME Local Time at stop of recording represented as : Reset number (integer starting at 1) / seconds The time resolution is 0.03125 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_TRIGGER" DATA_TYPE = CHARACTER START_BYTE = 136 BYTES = 8 FORMAT = "A8" MISSING_CONSTANT = 99999999 DESCRIPTION = "FIFO RAM address when trigger occurred in hexadecimal format (4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_BURST_OFF" DATA_TYPE = CHARACTER START_BYTE = 147 BYTES = 8 FORMAT = "A8" MISSING_CONSTANT = 99999999 DESCRIPTION = "FIFO RAM address when recording stopped in hexadecimal format (4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_FIRST_DAT" DATA_TYPE = CHARACTER START_BYTE = 158 BYTES = 8 FORMAT = "A8" MISSING_CONSTANT = 99999999 DESCRIPTION = "FIFO RAM address of very first channel data in hexadecimal format (4 bytes)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 168 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT-Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 175 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 182 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+X_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 189 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_TRM" DATA_TYPE = ASCII_REAL START_BYTE = 196 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMP_FOOT+Y_ACC" DATA_TYPE = ASCII_REAL START_BYTE = 203 BYTES = 6 FORMAT = "F6.2" UNIT = "KELVIN" DESCRIPTION = "Foot temperature before measurement" END_OBJECT = COLUMN