OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 25 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Measurement start time. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_U+5" DATA_TYPE = ASCII_REAL START_BYTE = 41 BYTES = 5 FORMAT = "F5.3" UNIT = "VOLT" DESCRIPTION = "Common electronics +5V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_U-5" DATA_TYPE = ASCII_REAL START_BYTE = 47 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "Common electronics -5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_U+12" DATA_TYPE = ASCII_REAL START_BYTE = 54 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "Common electronics +12V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_U-12" DATA_TYPE = ASCII_REAL START_BYTE = 61 BYTES = 7 FORMAT = "F7.3" UNIT = "VOLT" DESCRIPTION = "Common electronics -12V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_U+28" DATA_TYPE = ASCII_REAL START_BYTE = 69 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "Common electronics +28V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_UCDP" DATA_TYPE = ASCII_REAL START_BYTE = 76 BYTES = 5 FORMAT = "F5.3" UNIT = "VOLT" DESCRIPTION = "Common electronics Common DPU +5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_I+5" DATA_TYPE = ASCII_REAL START_BYTE = 82 BYTES = 6 FORMAT = "F6.2" UNIT = "MILLIAMPERE" DESCRIPTION = "Common electronics +5V current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_I-5" DATA_TYPE = ASCII_REAL START_BYTE = 89 BYTES = 6 FORMAT = "F6.2" UNIT = "MILLIAMPERE" DESCRIPTION = "Common electronics -5V current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_I+12" DATA_TYPE = ASCII_REAL START_BYTE = 96 BYTES = 6 FORMAT = "F6.2" UNIT = "MILLIAMPERE" DESCRIPTION = "Common electronics +12V current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_I-12" DATA_TYPE = ASCII_REAL START_BYTE = 103 BYTES = 6 FORMAT = "F6.2" UNIT = "MILLIAMPERE" DESCRIPTION = "Common electronics -12V current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_I+28" DATA_TYPE = ASCII_REAL START_BYTE = 110 BYTES = 6 FORMAT = "F6.2" UNIT = "MILLIAMPERE" DESCRIPTION = "Common electronics +28V current " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_SUPS" DATA_TYPE = CHARACTER START_BYTE = 118 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Common electronics SRAM usage/power status (hex value) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_TBO" DATA_TYPE = ASCII_INTEGER START_BYTE = 124 BYTES = 6 FORMAT = "I6" UNIT = "SECOND" DESCRIPTION = "Common electronics Time since boot " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_ERRF" DATA_TYPE = CHARACTER START_BYTE = 132 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Common electronics Error flags (hex value) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_CEID" DATA_TYPE = CHARACTER START_BYTE = 139 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Common electronics SESAME ID (hex value:B5E5) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_CLTC" DATA_TYPE = CHARACTER START_BYTE = 146 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Common electronics Last received TC (hex value) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CE_CBTC" DATA_TYPE = CHARACTER START_BYTE = 153 BYTES = 4 FORMAT = "A4" UNIT = "N/A" DESCRIPTION = "Common electronics Last but one TC (hex value) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TT-Y" DATA_TYPE = ASCII_REAL START_BYTE = 159 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot -Y/TRM temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TA-Y" DATA_TYPE = ASCII_REAL START_BYTE = 167 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot -Y/ACC temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TT+X" DATA_TYPE = ASCII_REAL START_BYTE = 175 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot +X/TRM temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TA+X" DATA_TYPE = ASCII_REAL START_BYTE = 183 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot +X/ACC temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TT+Y" DATA_TYPE = ASCII_REAL START_BYTE = 191 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot +Y/TRM temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TA+Y" DATA_TYPE = ASCII_REAL START_BYTE = 199 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE Foot +Y/ACC temperature The temperature range is limited by the range of the ADC of the C-DPU to (-104.52, 173.55) deg Celsius " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_TPCB" DATA_TYPE = ASCII_REAL START_BYTE = 207 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" DESCRIPTION = "CASSE board temperature " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_UFPG" DATA_TYPE = ASCII_REAL START_BYTE = 215 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "CASSE FPGA 3.3V " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CASSE_URAD_1S" DATA_TYPE = ASCII_REAL START_BYTE = 222 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "CASSE total dose (RADFET) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIM_UD_+5" DATA_TYPE = ASCII_REAL START_BYTE = 229 BYTES = 5 FORMAT = "F5.3" UNIT = "VOLT" DESCRIPTION = "DIM +5V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIM_UD_-5" DATA_TYPE = ASCII_REAL START_BYTE = 235 BYTES = 6 FORMAT = "F6.3" UNIT = "VOLT" DESCRIPTION = "DIM -5V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PP_UP_+5" DATA_TYPE = ASCII_REAL START_BYTE = 242 BYTES = 5 FORMAT = "F5.3" UNIT = "VOLT" DESCRIPTION = "PP +5V voltage " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PP_D" DATA_TYPE = ASCII_INTEGER START_BYTE = 248 BYTES = 5 FORMAT = "I5" UNIT = "N/A" DESCRIPTION = "PP electron density " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PP_IP_-5" DATA_TYPE = ASCII_REAL START_BYTE = 254 BYTES = 6 FORMAT = "F6.3" UNIT = "MILLIAMPERE" DESCRIPTION = "PP the current consumption of the PP digital electronics. The difference between UP+5 and the incoming +5 V supply voltage (U+05) is the voltage drop caused by the current (IP-5) through a 11.1 Ohm resistor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME_MEAS" DATA_TYPE = CHARACTER START_BYTE = 262 BYTES = 8 FORMAT = "A8" MISSING_CONSTANT = "99999999" DESCRIPTION = "Start time of each measurement. SESAME local time runs with a resolution of 31.25 ms represented in hexa value. Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 272 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot -Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 280 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot -Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 288 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot -Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 296 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot -Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 304 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot -Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 312 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot -Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 320 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot -Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 328 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot -Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 336 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot -Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 344 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot -Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 352 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +X/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 360 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot +X/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 368 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot +X/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 376 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot +X/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 384 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot +X/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 392 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +X/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 400 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot +X/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 408 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot +X/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 416 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot +X/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 424 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot +X/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 432 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 440 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot +Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 448 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot +Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 456 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot +Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 464 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot +Y/TRM Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 472 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 480 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for Foot +Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 488 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot +Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 496 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for Foot +Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 504 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for Foot +Y/ACC Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 512 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for CASSE PCB temperature Does not exist for Software Version FM1 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 520 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 1, for CASSE PCB temperature Does not exist for Software Version FM1 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 528 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for CASSE PCB temperature Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 536 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to to reference channel 2, for CASSE PCB temperature Does not exist for Software Version FM1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 544 BYTES = 7 FORMAT = "F7.2" UNIT = "KELVIN" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 2 = U + 28, for CASSE PCB temperature Does not exist for Software Version FM1" END_OBJECT = COLUMN