        This file describes the content of the CALIB directory                
"                                                                             
END_OBJECT                     = TEXT                                         
END                                                                           
***** File CALINFO.TXT ******                                                 
                                                                              
Contents of the CALIB Directory                                               
 RPCMAG_SC_ALIGN.ASC                                                          
 RPCMAG_SC_ALIGN.LBL                                                          
                                                                              
 RPCMAG_GND_CALIB_FSDPU_FMIB.ASC                                              
 RPCMAG_GND_CALIB_FSDPU_FMIB.LBL                                              
                                                                              
 RPCMAG_GND_CALIB_FSDPU_FMOB.ASC                                              
 RPCMAG_GND_CALIB_FSDPU_FMOB.LBL                                              
                                                                              
 RPCMAG_INFLIGHT_08_CALIB_IB.ASC                                             
 RPCMAG_INFLIGHT_08_CALIB_IB.LBL                                             
                                                                              
 RPCMAG_INFLIGHT_08_CALIB_OB.ASC                                             
 RPCMAG_INFLIGHT_08_CALIB_OB.LBL                                             
                                                                              
 RPCMAG_BOOM_ALIGN_CORR_EF1.ASC                                               
 RPCMAG_BOOM_ALIGN_CORR_EF1.LBL                                               
                                                                              
                                                                              
The CALIB directory contains all necessary information to generate            
calibrated magnetic field values from the Inboard (IB) and the                
Outboard (OB) sensor.                                                         
The following file are needed                                                 
1) RPCMAG_SC_ALIGN.ASC                                                        
2) RPCMAG_BOOM_ALIGN_CORR_EF1.ASC                                             
3) RPCMAG_GND_CALIB_FSDPU_FMIB.ASC                                            
4) RPCMAG_GND_CALIB_FSDPU_FMOB.ASC                                            
5) RPCMAG_INFLIGHT_08_CALIB_IB.ASC                                           
6) RPCMAG_INFLIGHT_08_CALIB_OB.ASC                                           
                                                                              
                                                                              
The first file contains the rotation matrices to turn the magnetic field      
vector from instrument coordinates to s/c-coordinates. There                  
are two matrices for each sensor: one for the stowed boom and one for         
the deployed boom position. The second file is used to correct the sensor     
orientation using the analysis result from the first Earth Flyby. By          
comparison with the POMME Earth magnetic field model it turned out, that the  
sensors have to be rotated by some hundredths  of a degree to get the best    
accordance with the model.                                                    
The two GND files contain all information to calculate the                    
temperature dependent sensitivity, misalignment and offset of the             
IB and OB sensors (FM units) connected to the Flight-spare (FS) DPU.          
This correction is based on Ground Calibration Results.                       
                                                                              
For an improvement of the calibration the two Inflight Calibration            
File for Temperature Model 008 are used. These two files (calculated          
on daily bases) contain the actual Temperature correction polynomial          
for the sensor offsets.                                                       
                                                                              
The temperature calibration model is still under development in order         
to adapt all effects seen during the quasi-continuous operations at CG.       
Temperature files are provided for every day, although they can               
contain the same coefficients. Temperature effects will be recalibrated       
after end of mission when also more spacecraft disturbances will be           
identified and a common calibration model can be  set up.                     
                                                                              
                                                                              
                                                                              
                                                                              
All files are read by the IDL s/w gen_cal_data.pro                            
                                                                              
The GND calibration algorithm  is described in the Calibration Analysis       
report Ro-IGM-TR-0003 (Chapters 7 -9),                                        
which can be found in the document directory. The Inflight calibration        
is described in the EAICD.                                                    
The complete calibration is described in the document RO-IGEP-TR0028 :        
Step by Step calibration procedure