/* Contents of format file "COSAC_ADC_MS.FMT" */ /* index of the cycle, and the tag inside the cycle */ OBJECT = COLUMN NAME = "CYCLE_INDEX" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 5 UNIT = "N/A" DESCRIPTION = "Index of the cycle containing the ADC_MS_ID tag" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "INSIDE_CYCLE" DATA_TYPE = ASCII_INTEGER START_BYTE = 7 BYTES = 5 UNIT = "N/A" DESCRIPTION = "Index of ADC_MS_ID tag in the same cycle" END_OBJECT = COLUMN /* ............... MS (16 parameters) ......................... */ OBJECT = COLUMN NAME = "PIPEA_M_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 13 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Pipe a (main)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PIPEB_M_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 22 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Pipe b (side)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OVEN_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 31 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Oven" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MSEBOX_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 40 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature MS-EBox" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALGAS_PRESSURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 49 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "Pressure Calibration Gas" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POSITION" DATA_TYPE = ASCII_INTEGER START_BYTE = 58 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "Position Tapping Station Open >= 4500, OT (Oberer Totpunkt/Top dead centre) ~ 4710, UT (Unterer Totpunkt/bottom dead centre) ~ 1330)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EMISSION_CURRENT" DATA_TYPE = ASCII_REAL START_BYTE = 67 BYTES = 8 UNIT = NANOAMPERE FORMAT = "F8.2" DESCRIPTION = "Emission current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV1_DET_V" DATA_TYPE = ASCII_REAL START_BYTE = 76 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 1, U detector" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV2_REFL2_4_V" DATA_TYPE = ASCII_REAL START_BYTE = 85 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 2, U reflector2_4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV3_REFL2_V" DATA_TYPE = ASCII_REAL START_BYTE = 94 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 3, U reflector 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV4_REFL1_V" DATA_TYPE = ASCII_REAL START_BYTE = 103 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 4, U reflector 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV5_LENSE2_V" DATA_TYPE = ASCII_REAL START_BYTE = 112 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 5, U lense 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV6_LENSE1_V" DATA_TYPE = ASCII_REAL START_BYTE = 121 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 6, U lense 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV7_G3_V" DATA_TYPE = ASCII_REAL START_BYTE = 130 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 7, U G3" END_OBJECT = COLUMN