DPU housekeeping temperature conversion into physical units. ----------------------------------------------------------- The following formula extracts from the measured voltage V, the resistance value RDPU. RDPU = 10000 * V / (10 - V) The following table provides the information to reconstruct the temperature from the calculated resistance. Resistance [ohm]|44135|14055|5700|2001|1146|583.1|318.7|184.7|113.1 Temperature|-40 C|-20 C|0 C|+25 C|+40 C|+60 C|+80 C|+100 C|+120 C Temperature is calculated by interpolating the measured resistance value with respect to the above coefficients.