PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM DATA_SET_ID = "MEX-M-MRS-1/2/3-MCO-0046-V1.0" STANDARD_DATA_PRODUCT_ID = ENB PRODUCER_ID = "SUE" PRODUCT_ID = "M00SUE0L1A_ENB_041391512_00.TXT" PRODUCT_CREATION_TIME = 2005-07-27T16:31:11.000 INSTRUMENT_HOST_ID = "MEX" OBJECT = TEXT PUBLICATION_DATE = 2005-06-10 NOTE = "MEX SUE Experimenter Notes" END_OBJECT = TEXT END From gene.goltz@jpl.nasa.gov Tue May 18 09:57:32 2004 Return-Path: Received: from eis-msg-012.jpl.nasa.gov (eis-msg-012.jpl.nasa.gov [137.78.160.40]) by magellan.Stanford.EDU (8.11.7p1+Sun/8.11.7) with ESMTP id i4IGvV424972 for ; Tue, 18 May 2004 09:57:31 -0700 (PDT) Received: from GGOLTZ-2K.jpl.nasa.gov (ggoltz-2k.jpl.nasa.gov [137.78.78.47]) by eis-msg-012.jpl.nasa.gov (8.12.10/8.12.10) with ESMTP id i4IGvVMM028947; Tue, 18 May 2004 09:57:31 -0700 (PDT) Message-Id: <5.1.0.14.2.20040518085434.018037b8@pop.jpl.nasa.gov> X-Sender: ggoltz@pop.jpl.nasa.gov X-Mailer: QUALCOMM Windows Eudora Version 5.1 Date: Tue, 18 May 2004 09:57:31 -0700 To: Dick Simpson 650-723-3525 From: Gene Goltz Subject: MEX 2004-139 Occultation Data Cc: sami Asmar Mime-Version: 1.0 Content-Type: text/plain; charset="us-ascii"; format=flowed Content-Length: 2124 Status: RO Dick, The MEX Occultation on DOY 139 (pass 0352) was performed over DSS-65. I recorded and played back RSR open-loop data as follows: - X-band, 2-way - RSR1B1 - 2 kHz, 16 bits - start = 15:12:00 - LOS = 15:27:06 (approximately) - stop = 15:32:00 - SFDUs = 1,201 and: - S-band, 2-way - RSR2B1 - 2 kHz, 16 bits - start = 15:12:00 - LOS = 15:27:06 (approximately) - stop = 15:32:00 - SFDUs = 1,201 These data should now be available for you to query. Regards, Gene P.S. The Bistatic Experiment will be this Thursday night (20 May). The timeline as given in the DKF is as follows (Bistatic is from about 08:45 pm (0345 UTC) to 09:15 pm (0415 UTC): ! 041 14 00394 141 210000 SPEC ADVISORY [BEGIN PASS ACTIVITY: @ T/P_BISTATIC_R/S] ! 041 14 00420 141 233000 BOT ! 041 14 00421 141 233000 ACQ D/L, 1-WAY, S/CH. 23 ! 041 14 00423 141 233100 ACQ U/L, X/CH. 25, 10.0KW/LOW ! 041 14 00431 142 000919 ACQ D/L, 2-WAY, S/CH. 25 ! 041 14 00433 142 001049 AOS, X/CH. 25 ! 041 14 00440 142 001049 ACQ D/L, 2-WAY, X/CH. 25 ! 041 14 00445 142 001326 TXR OFF, LOW, X ! 041 14 00446 142 005145 ACQ D/L, 1-WAY, X/CH. 23 ! 041 14 00447 142 005145 ACQ D/L, 1-WAY, S/CH. 23 ! 041 14 00449 142 013618 APOAPSIS ! 041 14 00450 142 022947 ACQ U/L, X/CH. 25, 10.0KW/LOW ! 041 14 00457 142 030617 TXR OFF, LOW, X ! 041 14 00458 142 030807 ACQ D/L, 2-WAY, X/CH. 25 ! 041 14 00459 142 034437 ACQ D/L, 1-WAY, X/CH. 23 ! 041 14 00460 142 034441 BEGIN RAD SCI ! 041 14 00461 142 034441 BEGIN SR FIXED ! 041 14 00462 142 035941 ENTER PLNT ATM, MARS ! 041 14 00463 142 040001 LOS, X/CH. 23 ! 041 14 00464 142 040001 ENTER OCC, MARS ! 041 14 00465 142 041001 END SR FIXED ! 041 14 00466 142 041001 END RAD SCI ! 041 14 00467 142 041500 EOT ! 041 14 00468 142 051500 SPEC ADVISORY [END POST-CAL]