Austrian Academy of Sciences Space Research Institute Department of Experimental Space Research ROSETTA-MIDAS To Planetary Science Archive Interface Control Document MID-IWF-TN-0087 Issue 2.0 16 November 2017 ______________________________ Prepared by: Harald Jeszenszky __________________________ Approved by: Mark Bentley Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 2 Distribution List Recipient Organisation Recipient Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 3 Change Log Date Sections Changed Reasons for Change 7 November 2003 All First draft 6 February 2006 All Updated draft 6 November 2006 All First formal release 21 February 2008 All Peer review update 27 October 2008 Minor updates 1 February 2013 All 2nd peer review update 1 April 2016 All 3rd peer review update 16 November 2017 4.2.1 Updated data products table October 2017 Science 4.2.6 Astronomical vs. MIDAS targets Archive Review update 4.3.7 Added pixel scale attributes to label Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 4 ITEMS Section Description Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 5 Table Of Contents 1 Introduction _________________________________________________________________________ 7 1.1 Purpose and Scope _______________________________________________________________ 7 1.2 Archiving Authorities _____________________________________________________________ 7 1.2.1 ESA's Planetary Science Archive (PSA)____________________________________________ 7 1.3 Contents ________________________________________________________________________ 7 1.4 Intended Readership ______________________________________________________________ 8 1.5 Applicable Documents ____________________________________________________________ 8 1.6 Relationships to Other Interfaces ___________________________________________________ 8 1.7 Acronyms and Abbreviations _______________________________________________________ 8 1.8 Contact Names and Addresses ______________________________________________________ 9 2 Overview of Instrument Design, Data Handling Process and Product Generation ________________ 10 2.1 Scientific Objectives _____________________________________________________________ 10 2.2 AFM Operating Modes___________________________________________________________ 11 2.3 Operating Principle______________________________________________________________ 12 2.4 Data Handling Process ___________________________________________________________ 13 2.5 Overview of Data Products _______________________________________________________ 13 2.5.1 Pre-Flight Data Products _______________________________________________________ 16 2.5.2 Sub-System Tests ____________________________________________________________ 17 2.5.3 Instrument Calibrations ________________________________________________________ 17 2.5.4 Other Files written during Calibration_____________________________________________ 18 2.5.5 In-Flight Data Products ________________________________________________________ 18 2.5.6 Software ___________________________________________________________________ 19 2.5.7 Documentation ______________________________________________________________ 22 2.5.8 Derived and other Data Products_________________________________________________ 22 2.5.9 Ancillary Data Usage _________________________________________________________ 22 3 Archive Format and Content ___________________________________________________________ 23 3.1 Format and Conventions _________________________________________________________ 23 3.1.1 Deliveries and Archive Volume Format ___________________________________________ 23 3.1.2 Data Set ID Formation ________________________________________________________ 23 3.1.3 Data Set Name Formation ______________________________________________________ 23 3.1.4 Data Directory Naming Convention ______________________________________________ 23 3.1.5 File Naming Convention _______________________________________________________ 24 3.2 Standards Used in Data Product Generation _________________________________________ 24 3.2.1 PDS Standards_______________________________________________________________ 24 3.2.2 Time Standards ______________________________________________________________ 24 3.2.3 Reference Systems____________________________________________________________ 25 3.2.4 Other Applicable Standards_____________________________________________________ 25 3.3 Data Validation _________________________________________________________________ 26 3.4 Content ________________________________________________________________________ 28 3.4.1 Volume Set / Data Set _________________________________________________________ 28 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 6 3.4.2 Directories __________________________________________________________________ 28 4 Detailed Interface Specifications ________________________________________________________ 32 4.1 Structure and Organization Overview ______________________________________________ 32 4.1.1 Data Processing Diagram ______________________________________________________ 32 4.1.2 Data Product Preparation ______________________________________________________ 33 4.2 Data Sets, Definition and Content __________________________________________________ 34 4.2.1 Data Set Production___________________________________________________________ 34 4.2.2 Instrument Mode Definition ____________________________________________________ 35 4.2.3 Data Quality Definition ________________________________________________________ 35 4.2.4 Geometry Information _________________________________________________________ 35 4.2.5 Mission Specific Keywords_____________________________________________________ 36 4.2.6 Astronomical Targets vs. MIDAS Targets _________________________________________ 37 4.3 Data Product Design _____________________________________________________________ 38 4.3.1 Data Product Design - Standard Housekeeping Data _________________________________ 38 4.3.2 Data Product Design - Extended Housekeeping Data_________________________________ 43 4.3.3 Data Product Design - Frequency Scan Data _______________________________________ 77 4.3.4 Data Product Design - Single Point Approach Data __________________________________ 82 4.3.5 Data Product Design - Single Point Sampling Data __________________________________ 88 4.3.6 Data Product Design - Line Scan Data ____________________________________________ 94 4.3.7 Data Product Design - Image Scan Data___________________________________________ 99 4.3.8 Data Product Design - Feature Vector Data _______________________________________ 101 4.3.9 Data Product Design - Event Data ______________________________________________ 107 4.3.10 Data Product Design - Cantilever Utilisation History Data ___________________________ 109 4.3.11 Data Product Design - Target Utilisation History Data ______________________________ 112 5 Appendix: Available Software to read PDS files ___________________________________________ 114 5.1 Program Description ____________________________________________________________ 115 5.1.1 Program Installation _________________________________________________________ 115 5.1.2 Starting the Program _________________________________________________________ 115 5.1.3 Navigating the Data Set_______________________________________________________ 115 5.1.4 Data Display _______________________________________________________________ 115 5.2 Program Source Files ___________________________________________________________ 116 5.2.1 MIDAS Data Set Browser _____________________________________________________ 116 5.2.2 Small Bodies Node (SBN) PDS Library __________________________________________ 117 6 Appendix: Example of Directory Listing of Data Set X _____________________________________ 118 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 7 1 Introduction 1.1 Purpose and Scope The purpose of this EAICD (Experimenter to (Science) Archive Interface Control Document) is twofold. At first, it provides users of the MIDAS instrument with a detailed description of the product and a description and the methods by which it is generated, including data sources and destinations. Secondly, it is the official interface between the MIDAS instrument team and the archiving authority. 1.2 Archiving Authorities The Planetary Data System Standard is used as an archiving standard by NASA for U.S. planetary missions, implemented by PDS ESA for European planetary missions, implemented by the Research and Scientific Support Department (RSSD) of ESA 1.2.1 ESA's Planetary Science Archive (PSA) ESA implements an online science archive, the PSA, to support and ease data ingestion to offer additional services to the scientific user community and science operations teams as e.g. o search queries that allow searches across instruments, missions and scientific disciplines o several data delivery options as direct download of data products, linked files and data sets ftp download of data products, linked files and data sets The PSA aims for online ingestion of logical archive volumes and will offer the creation of physical archive volumes on request. 1.3 Contents This document describes the data flow of the MIDAS instrument on ROSETTA from the S/C until insertion into the PSA for ESA. It includes information on how data were processed, formatted, labelled and uniquely identified. The document discusses general naming schemes for data volumes, data sets, data and label files. Standards used to generate the product are explained. Software that may be used to access the product is explained further on. The design of the data set structure and the data product is given. Examples of these are given in the appendix. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 8 1.4 Intended Readership The staff of the archiving authority (Planetary Science Archive, ESA, RSSD, design team) and any potential user of the MIDAS data. 1.5 Applicable Documents [1] Planetary Data System Data Preparation Workbook February 17, 1995, Version 3.1, JPL D-7669, Part1 [2] Planetary Data System Standards Reference August 1, 2003, Version 3.6, JPL D-7669, Part 2 [3] ROSETTA Archive Generation, Validation and Transfer Plan October 6, 2005, Issue 2.2, RO-EST-PL-5011 [4] ROSETTA Experiment Interface Document - Part A February 1, 2004, Issue 2, Rev. 3, RO-EST-RS-3001/EIDA [5] ROSETTA - MIDAS Experiment Interface Document - Part B February 15, 2001, Issue 2d, Rev. 0, RO-EST-RS-3010/EIDB [6] ROSETTA - Data Delivery Interface Document (DDID) October 23, 2003, Issue B6, RO-ESC-IF-5003 [7] MIDAS User Manual February 23, 2004, Issue 2, Rev. 1, MID-IWF-UM-0047 [8] ROSETTA Time Handling February 28, 2006, Issue 1, Rev. 1, RO-EST-TN-3165 [9] MIDAS Co-ordinate Systems October 28, 2008, Issue 1.0, MID-IWF-TD-0029 1.6 Relationships to Other Interfaces N/A 1.7 Acronyms and Abbreviations AFM Atomic Force Microscope DAQ Data Acquisition DDID Data Delivery Interface Document DDS Data Disposition System EAICD Experimenter to (Science) Archive Interface Control Document EGSE Electrical Ground Support Equipment FM Flight Model FS Flight Spare Model Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 9 IDL Interactive Data Language IWF/OAW Space Research Institute of the Austrian Academy of Sciences JPL Jet Propulsion Laboratory LVDT Linear Variable Differential Transformer MIDAS Micro-Imaging Dust Analysis System N/A Not applicable NAIF The Navigation and Ancillary Information Facility, JPL/NASA NASA National Aeronautics and Space Administration OBT S/C On-board Time (Spacecraft Elapsed Time according to [4]) PDS Planetary Data System PSA Planetary Science Archive QM Qualification Model SCET Spacecraft Event Time (according to [6]) SPM Scanning Probe Microscope STM Scanning Tunneling Microscopy TB/TV Thermal Balance/Thermal Vacuum 1.8 Contact Names and Addresses Mark Bentley, IWF/OAW, mark.bentley@oeaw.ac.at, +43 (0)316 4120 657 Harald Jeszenszky, IWF/OAW, harald.jeszenszky@oeaw.ac.at, +43 (0)316 4120 533 Jens Romstedt, ESA/ESTEC, jens.romstedt@esa.int, +31 (0)71 565 5761 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 10 2 Overview of Instrument Design, Data Handling Process and Product Generation 2.1 Scientific Objectives The experiment MIDAS (Micro-Imaging Dust Analysis System) is dedicated to the micro textural and statistical analysis of cometary dust particles. The instrument is based on the technique of atomic force microscopy. Under the conditions prevailing at the Rosetta Orbiter this technique permits textural and other analysis of dust particles to be performed down to a spatial resolution of 4 nm. During the rendezvous with the comet MIDAS will provide the following information: images of single particles with a spatial resolution of 4 nm, statistical evaluation of the particles according to size, volume, and shape, size distribution of particles ranging from about 4 nm to a few um, shape, volume and topographic structure of individual particles, temporal variation of particle fluxes, spatial variation of particle fluxes, and measurements on local elastic properties if further studies show that they do not affect the tip lifetime During the cruise phase to the comet MIDAS may provide: characterization of the dust environment in the vicinity of the asteroids for which a fly-by is performed imaging of impact craters caused by fast interplanetary dust particles, and statistical analysis of craters on the exposed surface in terms of particle size and volume MIDAS will deliver global images, i.e. complete images of the entire scan field, and images of individual dust particles. The latter are contained in the former, since selected particles are identified from the global image. These particles are then re-scanned with a much higher resolution. The measurements by the MIDAS instrument will address many of the questions related to cometary dust. In particular, the MIDAS instrument can measure and address the following qualities of the collected dust grains: 3D images of single particles Images of the textural complexity of particle aggregates Identification of crystalline material if idiomorphic or hypidiomorphic shapes are developed Identification of sub-features on clean surfaces which provides insight into the growth conditions (e.g. twinning defects) and/or storage environment (e.g. dissolution marks) Statistical evaluation of the particles according to size, volume and shape Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 11 Variation of particle fluxes between individual exposures of the collector unit on time scales of hours Four out of the sixteen sensors are capable of detecting a magnetic gradient between sensor and sample and allow the identification of ferromagnetic minerals or the visualisation of the internal magnetic structure of a grain. 2.2 AFM Operating Modes Contact mode The working point is set close to the repulsive force regime where the tip actually touches the surface. Typically, a force of the order 10-7-10-6 N is exerted on the sample. Owing to the strongly increasing repulsive force at decreasing distances, the tip cannot penetrate deeply into the surface and the soft cantilever bends. However, the pressure exerted by the tip is high and soft samples, particularly, can be scratched or damaged. Dynamic mode The cantilever is excited at its natural mechanical resonance frequency (100 kHz) at close distance to the sample. The amplitude of the cantilever vibration is of the order 100 nm. Depending on the operational setting, the tip may or may not touch the sample during each oscillation. At small tip-sample separation of the order 5-10 nm, the interaction of the electron orbits results in a weak attractive force, and the resonance frequency of the cantilever changes owing to a virtual increase in its spring constant. The quantity thereby measured is not the force directly, but its gradient. As in the contact mode, vertical resolution in the nm range can be achieved. The force applied by the tip to the sample is of the order 10-8 N. This relatively small force and the absence of lateral forces makes damage to the tip less likely, and the lifetime of the tip increases considerably. The lateral resolution obtained in dynamic mode is comparable to that of the contact mode. However, dynamic mode images often represent not only the topography, but also to some extent the elastic properties of the sample under investigation. The mechanical resonance frequency of the cantilever has to be determined before any measurement in dynamic mode. Magnetic force microscopy This derivative of atomic force microscopy (Martin and Wickramasinghe, 1987) records a magnetostatic force between sample and a magnetised tip. Four of the MIDAS tips have been coated with a thin layer of cobalt. The deflections of their cantilevers then result from a combination of mechanical and magnetic forces, which can be separated by measurements at two different tip-sample distances. These tips map the magnetic structures of the particles in addition to the topographies. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 12 2.3 Operating Principle MIDAS is designed to analyse micro dust particles collected in the cometary environment, irrespective of their electrical conductivity and shape, by means of atomic force microscopy. The size of the particles which can be analysed ranges from about 4 nm to a few um. The dust collector system includes a shutter mechanism which controls the particle flux onto a wheel covered with special coating to provide maximum adhesion for the particles. Sixty-one separate targets at the wheel are available for subsequent exposure to the ambient dust flux. The MIDAS microscope consists of five functional parts: a one shot cover and a funnel to protect the aperture on the ground and during launch, the shutter to define the exposure time to the dust flux, the robotics system for manipulation of the dust particles, the scanner head, and the supporting electronics. Fig. 2.1 - MIDAS Working Principle At the heart of the atomic force microscope (AFM) is a very small tip which maps the surface of the particle. An AFM is capable, in principle, of imaging details down to atomic resolution. In the simplest case, the tip remains in permanent contact with the surface and follows its height variations with a control mechanism which keeps a constant force on the tip (contact mode). In a technically more complex mode, the tip scans the surface while its supporting cantilever vibrates at one of its natural resonance frequencies. Depending on the amplitude of the oscillation in dynamic mode, (a) the tip does not come closer to the surface than a few tenths of a nanometre (non-contact mode) or (b) the tip hits the surface during its sinusoidal oscillation (tapping mode). In all modes it is essential either to keep the force constant or to measure it accurately in order to derive an image of the surface. The tip must move over the surface in a reproducible manner, which can be relatively easily achieved by piezo electric scanners in three independent directions. The combination of the tip, supporting cantilever, and piezo-electric actuators is called scanner head. Due to lifetime requirements, several tips will be employed (16 in total). Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 13 2.4 Data Handling Process The data products will be prepared and delivered by IWF/OAW in collaboration with partners from ESTEC. A list of contact persons, phone numbers and email addresses is given in section 1.8. All data products are planned to be level 1b and/or level 2 data (PSA processing label) throughout the whole mission lifetime. Higher level data products will be included in the final archive volume distribution. It is foreseen to use most of the already developed EGSE software modules for data processing. This software will be adapted to generate the data products from the raw data archive (locally stored laboratory data as well as DDS data after launch). 2.5 Overview of Data Products The table below shows the data products which are intended to be archived. A detailed description of the different data types follows. Data Type Type Mnemonic PDS Data Type Housekeeping Data (Standard, Extended) HK1, HK2 TABLE Frequency Scan Data FSC SERIES Single Point Approach Data (Control Data) SPA TABLE Single Point Sampling Data (High Resolution Data) SPS SERIES Line Scan Data LIN TABLE Image Scan Data IMG IMAGE Feature Vector Data (Regions Of Interest) ROI TABLE Event Data EVN TABLE Cantilever Utilisation History CAH TABLE Target Utilisation History TGH TABLE Table 2.1 - MIDAS Archive Data Products Housekeeping Data MIDAS generates two types of housekeeping data: The standard housekeeping report contains basic information and reflects the "general condition" of the instrument (e.g. voltage monitors, temperatures). The much larger extended housekeeping report includes the status of the instrument sub-systems (e.g. linear stage, approach) and all parameters related to the science operations. Typical data cadences are 4 seconds for the standard HK report and 8 seconds for the extended HK report for laboratory generated data. The individual data rates can be changed via telecommand and will be much lower during normal flight operations. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 14 Frequency Scan Data In order to set the operating point (excitation frequency) for a certain cantilever (tip), the resonance frequency has to be determined. This is achieved by performing a frequency sweep in a commanded frequency range. The operating point is set relative to the detected resonance amplitude. A frequency scan produces up to 8 data packets (depending of the commanded frequency range and resolution) of 256 data acquisition points each. The frequency scan is performed every time approaching the surface, whenever a new tip is selected, or during long-lasting (dynamic) scans when re-adjustment of the frequency is required. The cantilevers (tips) are numbered from 1 to 16 and are addressable by 2 blocks of 8 cantilevers each (physically the cantilevers are structured into four cantilever arrays): Cantilever selection Tip # Description Block # Cantilever # 1-4 Cantilever array #1 1 1-4 5-8 Cantilever array #2 1 5-8 9-12 Cantilever array #3 2 1-4 13-16 Cantilever array #4 (cobalt coated) 2 5-8 Tip, cantilever block and cantilever number are also present in the extended housekeeping data product. Please note that the cantilever number ranges from 0 to 7 in this data product. Single Point Approach Data The MIDAS instrument software is capable of monitoring selected data acquisition process parameters (cantilever AC, DC and phase signal; Z set value) simultaneously in a single scan position. This feature can be enabled or disabled when performing a line scan and is not available for the full image scan. The associated data packet contains the last 256 processed parameter values before the measurement reading is recorded. During a line scan, 32 uniformly distributed positions are monitored. The parameter MAIN_SCAN_CNT indicates the pixel number within the line where the approach vector has been recorded. Single Point Sampling Data The data acquisition monitoring structure is also used for a more complex instrument mode. This "high resolution" scanning mode allows the sampling of the above-mentioned parameters with a frequency of up to 700 samples per second. The scanner head remains in the same X/Y position when taking the data samples (STEP_SIZE parameter is 0). Thus the Single Point Sampling data product corresponds to a single point located on the target surface. By getting into contact with the surface (static or DC mode), the cantilever DC signal can be used to measure micro-vibrations with a maximum frequency of 350 Hz. This mode is frequently used during the pointing and interference scenario. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 15 In order to detect possible micro-vibrations, a Fast Fourier Transform (FFT) has to be applied to the DC sample vector. Analysis of the resulting frequency spectrum will give an indication (spectral lines with higher amplitude) on micro-vibrations. Line Scan Data Additionally to the full image scan, MIDAS is able to scan single lines in either X or Y direction. The line scan values have two different meanings depending on the commanded scanning mode: In dynamic or contact mode the Z piezo set values at the surface are stored in the line scan. In magnetic mode the differences of the cantilever AC signals at the surface and at a given distance from the surface are recorded. The size of a line scan is a multiple of 32, ranging from 32 to a maximum of 512 DAQ points. Image Scan Data The image scan is the key operation of the instrument MIDAS. The on-board image memory of 1 MB can hold a maximum of 8 standard images (256x256 pixel / 1 DAQ channel = 128 kB). The image dimensions are multiples of 32 pixels, ranging from 32 to a maximum of 512 DAQ points. During a single image scan up to 8 data channels can be measured in parallel. At the present time 14 data channels are available (the value in curly braces gives the calibration curve number as defined in the calibration table MIDCALIB.TAB defined in chapter 3.4.2.2): [ZS] Z piezo set value (this is the default channel for all scanning modes) {40} [AC] Cantilever AC signal at surface (required for magnetic mode) {3} [PH] Cantilever Phase signal {13} [DC] Cantilever DC signal {3} [XH,YH,ZH] X, Y, Z piezo high voltage monitor {8} [M1,M2,M3] Cantilever AC signal at (magnetic) retract position 1,2,3 {3} [YP,ZP] Y, Z piezo position (measured) {3} [YE,ZE] Y, Z piezo offset error (control loop deviation set value / measured value) {3} [S1,S2] Data point acquisition status information If more than one data channel is selected for a scan, the software generates a separate image for every channel. Feature Vector Data Another facet of the instrument software is the calculation of so-called "feature vectors" for an already acquired image. These vectors are providing statistical information (10 parameters in total) of features found in the image, for example area or volume. The features are selected dependent on a number of commandable criteria. By weighting the selection criteria, it is possible to determine a feature which suits best the given requirements. The coordinates of the determined feature can then be used to automatically zoom-in into the underlying image. A maximum of 1024 feature vectors can be stored for a single image. The vectors are packed into statistical data packets containing 64 vectors each. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 16 Event Data Every task (e.g. mechanical sub-system movement, scan, image processing) running on the instrument has associated a number of events providing information about the status of the task (e.g. started, finished and aborted). In order to keep track of the task execution, the events will also be part of the MIDAS data archive. A list of events is given in the MIDAS User Manual in section 2.3.3.1 "TM data packet overview". Cantilever Utilisation History Data The MIDAS scanner head holds 16 different cantilevers (tips) mainly for redundancy purposes, and four of these tips are coated with magnetic material and may be used for magnetic mode scans. For the interpretation of the AFM images it is necessary to know the history of the tip which has been used for the image acquisition. A list of operating times and associated scanning parameters (e.g. scanning mode, gain levels and excitation level) will be stored for each cantilever. The cantilever history files are cumulative, containing the data from the start of the mission up to and including the mission phase represented in a dataset. Target Utilisation History Data For each of the 64 scanning targets (including the three calibration targets) a list of events concerning the target will be maintained and stored in the archive. Dedicated information like the dust flux during exposure recorded by GIADA or the scanning tip number will be stored in this table. The targets are numbered from 1 to 64 and each target is subdivided into 16 addressable segments (or scan bands). This results in a total number of 1024 addressable target segments. The segments are numbered from 0 to 1023, with segment 0 referring to the centre of target 1: Target # Description Addressed by segment # Min Centre Max 1 Dust collector target 1017 0 7 2 TGZ02 - Z calibration (106 nm height) 9 16 23 3 TGX01 - used for X/Y calibration 25 32 39 4 TGT01 - X/Y calibration and tip imaging 41 48 55 5 Dust collector target 57 64 71 ... 64 Dust collector target 1001 1008 1015 The target history files are cumulative, containing the data from the start of the mission up to and including the mission phase represented in a dataset. 2.5.1 Pre-Flight Data Products MIDAS will provide laboratory data from the TB/TV acceptance tests of the FM. Since the generation of the feature vectors was not implemented in the instrument S/W at that time, it is also intended to create a data set from dedicated FS or QM tests. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 17 2.5.2 Sub-System Tests A series of micro-vibration tests were performed on the QM. 2.5.3 Instrument Calibrations X/Y/Z Calibration The X-, Y- and Z-sensors of the MIDAS instrument are calibrated by means of three reference grids which are mounted on the target wheel. These reference grids are scanned on a more or less regular basis in order to re-calibrate the scanner head: TGX01 - used for X/Y calibration The silicon calibration grating of the TGX series is a chessboard-like array of square pillars with sharp undercut edges formed by (110) crystallographic planes of silicon. TGZ02 - Z calibration (106 nm height) Calibration gratings of the TGZ series are 1-D arrays of rectangular SiO2 steps on a Si wafer. The structure is coated by Si3N4 to prevent Si from oxidation. The step height value is calibrated over the whole active area. TGT01 - X/Y calibration and tip imaging The silicon calibration grating of the TGT01 series is an array of sharp tips, characterized by strict symmetry of tip sides, small cone angle (less than 20 degrees) and small curvature radius of the tips (less than 10 nm) over the whole active area. The dimensions marked (*) show approximate values and are given for information only. The archive will contain the following calibration data: Tip resonance curves as a function of the excitation frequency in [V] Tip positions as a function of the linear stage LVDT monitor in [V] and [um] (see [9]) Tip images acquired by sampling calibration grating TGT01 X/Y step calibration (can be derived from sampling calibration grating TGX01) Z step calibration (can be derived from sampling calibration grating TGZ02) HK parameter conversion from raw to physical values 0.7 um* Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 18 2.5.4 Other Files written during Calibration Numerous reference measurements with commercial AFM's (Zeiss, Park) have been performed. The resultant image database is used as reference for the analysis and interpretation of MIDAS generated images. 2.5.5 In-Flight Data Products A list of data products as well as a detailed description is already provided at the beginning of section 2.5. The data products are planned to be level 1b and/or level 2 data (PSA processing label) throughout the whole mission lifetime. Higher level data products are likely to be included in the final archive volume distribution. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 19 2.5.6 Software 2.5.6.1 Data Archiving Software The MIDAS data archiving software is a graphical user interface written in IDL and is used to prepare the MIDAS archive data sets to be delivered to the PSA. Fig. 2.2 - MIDAS Data Archiving S/W Key features of the archiving software are: Data sets are created directly from the MIDAS raw data archive by means of data set templates which are completed during data processing. The S/W is capable of managing so called "data set profiles" in order to ease re- production of entire data sets. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 20 A number of label verification tools (PVV, NASA PDS tools) are already integrated into the archiving software. This allows the user to validate the data sets immediately after generation. 2.5.6.2 Data Verification Software This software is used to display and validate the contents of an entire MIDAS archive data set interactively. The software is entirely written in IDL and the source code is included in the data sets. The source files (extension *.PRO) are located in the DOCUMENT directory of a data set. A detailed description of the software is provided in section 5. 2.5.6.3 Third Party Software Packages NASAView NASAView (http://pds.nasa.gov/tools/nasa-view.shtml) is a PDS archive product display program that runs on multiple platforms in a GUI environment. The tool can be used to view the MIDAS images located in the DATA/IMG directory. Fig. 2.3 - MIDAS Image taken during LUTETIA Fly-by PDS Tools Package The PDS Tools Package (http://pds.nasa.gov/tools/pds-tools-package.shtml) is the complete set of PDS Engineering Node supported tools. This package contains a single installer file which includes the option to install the following tools: Keyword Definition (ddict): Lists all keywords and their definitions from the specified file(s). Keyword Verifier (kwvtool): Lists all keywords and a distinct set of their values from the specified file(s). Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 21 Label Parser: The Java-based label parser parses an ODL label and generates an XML representation. Label Verifier (lvtool): Performs validation of PDS labels. Line Analyzer (line): Analyzes each line of a file and reports anomalies. Make Index (make_index): Creates an index file (pdsdd.idx) from a data dictionary file (pdsdd.full). Perl Validation Toolkit: Validates PDS volumes (includes lvtool and kwvtool). Table Checker (table_check): Performs a variety of tests on PDS table objects. Table to Label Generator (tab2lab): Generates PDS labels from values in a table. Table Verifier (tbtool): Utility for validating, browsing and summarizing data that is organized by rows and columns and is described by a PDS label. The PDS Tools Package also includes libraries which are utilized by the tools listed above and are available for use in customized applications: Label Library (lablib): This library, written in C, can be used to read, process and write PDS labels. Label Library Light (lablib3): This library, written in C, can be used to read, process and write PDS labels. Compared to lablib, this library is smaller, faster and has a simpler interface. ODLC Library (odlc): This library, written in C, can be used to access data that meet the standards of the PDS. Object Access Library (oal): This library, written in C, can be used to access data that meet the standards of the PDS. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 22 2.5.7 Documentation The following documents will be included in the MIDAS archive DOCUMENT directory: MIDAS User Manual MIDAS EAICD MIDAS Co-ordinate Systems MIDAS instrument paper as presented in the Space Science Review (2007) These documents are converted to ASCII format. Associated drawings are stored as "Portable Network Graphic" (PNG) files. In addition, PDF versions of the listed documents are available from the same directory. 2.5.8 Derived and other Data Products N/A 2.5.9 Ancillary Data Usage N/A Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 23 3 Archive Format and Content 3.1 Format and Conventions 3.1.1 Deliveries and Archive Volume Format The logical archive volumes will contain one data set per volume. Up to now, three basic types of logical archive volumes are planned: Selected laboratory data Checkout data generated during flight (cruise phase) Data acquired in the close comet environment (cometary phase) 3.1.2 Data Set ID Formation The MIDAS data set identifiers are defined as follows (see archive plan [3]): "RO-{target ID}-MIDAS-{level}-{phase}-{description}-Vx.y" {target ID} = {C, A, E, M, CAL, X, D, SS, C} {level} = processing level = {3, 5} {phase} = mission phase = {GRND, CVP, CR1, ...} {description} = free character string containing only A-Z, 0-9 (e.g. TV) 3.1.3 Data Set Name Formation The MIDAS data set names are defined as follows (see archive plan [3]): "ROSETTA-ORBITER {target name} MIDAS {level} {phase} {description} Vx.y" {target name} = {67P, STEINS, LUTETIA, ...} {level} = processing level = {3, 5} {phase} = mission phase = {GRND, CVP, CR1, ...} {description} = free character string containing A-Z, 0-9, - (e.g. TV-TEST) 3.1.4 Data Directory Naming Convention For all data sets the data directory is structured as follows: /DATA[/{data type}]/file(s) {data type} = {EVN, FSC, HK1, HK2, IMG, LIN, ROI, SPA, SPS} Cantilever and target history files (CAH, TGH) are stored in the data directory root. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 24 3.1.5 File Naming Convention The following file naming scheme will be used for all data sets (the "extra" field is optional and depends on the data type): {data type}_{start}_{stop}[_{extra}].{ext} {data type} = {CAH, EVN, FSC, HK1, HK2, IMG, LIN, ROI, SPA, SPS, TGH} {start} = begin of observation rounded to nearest hour, format = yydddhh {stop} = end of observation rounded to nearest hour, format = yydddhh {extra} = more specific information about the file content: data type extra information possible values field format HK1, HK2,EVN not used FSC, SPA, sequence counter [nnn] 001..FFFSPS, LINtip number [tt]01..16nnn_tt sequence counter [nnn] 001..999 IMG DAQ channel [dd] ZS, AC, PH, DC,M1,M2,M3,XH,nnn_dd YH, ZH, YP, ZP, YE, ZE, S1, S2*) sequence counter [nnn] 001..999 ROI nnn_ff target number [ff] 01..64 CAH tip number [tt] 01..16 tt TGH target number [ff] 01..64 ff *) A description of the DAQ channels is given in section 2.5 (Image Scan Data). {ext} = depends on the data type (e.g. IMG for images, DAT/TAB for binary/ASCII tables) 3.2 Standards Used in Data Product Generation 3.2.1 PDS Standards The MIDAS archive is based on the PDS Standard version 3.6 released in August 2003. 3.2.2 Time Standards All MIDAS timing information of archive data products that are mapped to binary tables (e.g. housekeeping data telemetry packets), is given in the Spacecraft Elapsed Time (referred to as OBT to prevent confusion with the SCET defined in the DDID) format as defined in [4], section 2.7. The format used to represent the OBT is 4 bytes of unit seconds followed by 2 bytes of fractional seconds and is stored in the TM packet data field header. The OBT is set to zero at 00:00:00 UTC on 1 Jan 2003. The instrument is synchronised with the S/C OBT on a regular Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 25 basis (typically every 30 minutes). In order to convert the OBT to UTC the NAIF SPICE software library is used. A more detailed description of the ROSETTA time standards is given in [8]. To represent UTC time values in archive data products represented by ASCII tables (e.g. cantilever history data), the ASCII Time Code A format, defined by the Consultative Committee for Space Data Systems (CCSDS) is used. The ASCII Time Code A is a 24 character string of the format "YYYY-MM-DDThh:mm:ss.dddZ". According to the archive plan the trailing "Z" is omitted and no quotes are used In ground-based data sets the OBT reference is 00:00:00 UTC on 1 Jan 1970. Since the S/C clock is not defined for ground based data, there is no relationship between the SPACECRAFT_CLOCK_START/STOP_COUNT keywords (set to "N/A") and the START/STOP_TIME keywords (representing UTC) in the data labels. This has been taken into account by adding the NATIVE_START/STOP_TIME keywords to the data labels. The native start/stop time is given in seconds since 00:00:00 UTC on 1 Jan 1970 with leap seconds not taken into account (also referred to as UNIX time). 3.2.3 Reference Systems MIDAS Coordinate Systems The following reference systems are applicable to the MIDAS instrument: Unit Reference Frame: The basic co-ordinate system to be used for MIDAS at instrument level. AFM Reference Frame: The ARF system is used in the context of scanner operations and is fixed to the frame of the scanner table. Target Reference Frame: Defines the co-ordinate system on any individual target area (or target) on the collector. A detailed description of the MIDAS X/Y/Z reference systems can be found in the MIDAS Co- ordinate Systems document [9]. J2000 System The Earth Mean Equator and Equinox of Julian Date 2451545.0 (referred to as the J2000 system) is the standard inertial reference frame. Some of the geometry keywords given in the data labels are expressed in J2000 coordinates (e.g. SC_SUN_POSITION_VECTOR). 3.2.4 Other Applicable Standards In order to represent and store the images in the MIDAS archive, the raw data images are converted to BCR. The BCR-STM file format has been developed for easy exchange of SPM files independent of the instruments used (see SPIP Reference Guide at http://www.imagemet.com/WebHelp6/Default.htm). The header is 2048 bytes long and written in ASCII characters, which can be edited by a text editor. The first line identifies the format and should be: fileformat = bcrstm Additional parameters are defined as follows: xpixels and ypixels defines the number of pixels in the image xlength and ylength defines the scanning range in nm Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 26 xunit, yunit and zunit units for the three axes (if not defined nm will be the default unit) current defines the tunneling current in nA (optional) bias defines the bias voltage in V (optional) starttime defines the starting time of the scanning (DD MM YY hh:mm:ss:hh) (optional) scanspeed is measured in nm/sec (optional) intelmode = 1 indicates that the data is written in little-endian 16-bit integers (LSB first; e.g. Intel x86 processors) intelmode = 0 indicates that the data is written in big-endian 16-bit integers (MSB first; e.g. Motorola 6800 processors) bit2nm is the scale factor for scaling the integer height data to nm xoffset and yoffset defines physical offset in nm (optional) voidpixels defines the value of void pixels (should be set equal to 32767; if omitted, the value is assumed to be 0) Comments can be written by starting the line with the characters `%' or `#'. It is possible to integrate new parameters as long the header size does not exceed 2048 bytes. The body of the BCR file contains xpixels*ypixels 16 bit signed integer data values. 3.3 Data Validation The following tools are used in order to validate the generated MIDAS data sets: PSA Volume Verifier (PVV) The PVV is a tool constructed by the PSA team to allow instrument teams from all of ESA's planetary missions to check their datasets before they are delivered to the PSA database for ingestion into the long-term archive. The tool allows a user to verify PDS compliance of a label, and validates all aspects of the data set structure / content prior to delivery to the PSA. The PVV is systematically used by the PSA team to check data sets as part of the ingestion process to the Planetary Science Archive (PSA). NASA PDS Tools The PDS Tools Package is the complete set of PDS Engineering Node supported tools. The following tools of the package are used: ddict - Extracts the data dictionary definition for every keyword used in a specified PDS label file, a specified list of PDS label Files, all of the labels in a directory, or all of the files on an entire volume. DDICT also lists those keywords that are not in the dictionary. kwvtool - This software creates a list of all keywords and their values found in a PDS label file or in a group of PDS label files. line - The LINE program analyzes each line in each file and reports on the status of certain PDS standards and the value associated with some of the PDS keywords. lvtool - This software checks PDS labels for compliance with the labeling standards established by the PDS for data product labels. NASAView - This program allows the user to display and examine PDS archive data products interactively. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 27 table_check - The table checker program is a tool that checks PDS labels and its corresponding data files. It parses a label, checks for label and data errors (BINARY or ASCII files), and reports and summarizes its findings. tbtool - The PDS Table Browser is a utility for validating, browsing, and summarizing data that is organized by rows and columns and is described by a PDS label file. MIDAS Data Set Browser This software is used to display and validate the contents of an entire MIDAS archive data set interactively. The software is entirely written in IDL and the source code files are included in the DOCUMENT directory of the data sets (see chapter 5). Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 28 3.4 Content The MIDAS archive will contain data from important laboratory measurements, instrument checkout data generated in the interplanetary cruise phase and instrument data acquired in the close comet environment, as well as derived or merged instrument data e.g. the cantilever utilisation history or the target exposure history. 3.4.1 Volume Set / Data Set The Rosetta archive is an online archive, where the data are delivered electronically. Thus there is no need to bundle several data sets into one volume, and one data set corresponds to one volume. A data set will include the data products as well as the secondary data, software and documentation that completely document and support the use of these data products. In general, the data products from the different instruments are contained in separate data sets, but merged data sets are possible. Data sets may include data products from one or more mission phases. Data products of different data processing levels are contained in separate data sets. 3.4.2 Directories The top-level structure of the ROOT directory of a typical MIDAS data archive volume (= data set) corresponds to chapter 19 of the PDS Standards Reference [AD2] and is summarised below: 3.4.2.1 Root Directory .PDSVOLUME: Archive data file catalogue generated by PVV. AAREADME.TXT: This file describes the volume (= data set) as a whole. It gives an overview of the contents and organisation of the data set, general instructions for its use and contact information. ERRATA.TXT: This file describes errors and/or anomalies found in this and previous volumes (= data sets). As erroneous data sets should be corrected and delivered again, there is no need for this file. VOLDESC.CAT: This file contains the VOLUME object, which gives a high-level description of the contents of the volume (= data set). 3.4.2.2 Calibration Directory This directory contains the calibration files used in the processing of the raw data or needed to use the data products in the volume (= data set). CALINFO.TXT: Description of the contents of the CALIB directory. MIDCALIB.LBL: PDS label associated to the standard MIDAS calibration table. MIDCALIB.TAB: Standard MIDAS calibration table in PDS ASCII format. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 29 The following table shows the standard calibration curves used for MIDAS housekeeping and science data calibration: Reference Calibration#Offset CalibrationFactorUnit Description 1 0.0 1.0 One to one conversion 2 -10.0 4.884005E-03 V 12 bit DAC set value [-10..10 V] 3 0.0 3.051804E-04 V 16 bit ADC data [-10..10 V] 4 -10.0 3.051804E-04 V 16 bit DAC set value [-10..10 V] 5 -273.0 1.142998E-02 degC Temperature [-273..101.52 C] 6 0.0 9.170596E-04 V +15 voltage monitor [-30..30 V] 7 0.0 9.170596E-04 V -15 voltage monitor [-30..30 V] 8 100.0 4.272530E-03 V Piezo HV voltage monitor [-40..240 V] 9 0.0 1.0 um Linear position set value [0..65535 um] 10 0.0 0.1 um XY stage positioning [0..6553.5 um] 11 0.0 2.136263E-01 nm XYZ position monitor [0..14000 nm] 12 21.0 42.0 us Pulse generator pulse width[21..2752491 us] 13 0.0 5.493248E-03 deg Cantilever phase signal [-180..180 deg] 14 0.0 1.525902E-03 % F-scan operating variables [0..100 %] 15 0.0 4.577034E+01 Hz Frequency high word [0..2999.56 kHz] 16 0.0 6.984E-04 Hz Frequency step/low word [0..45.77 Hz] 17 0.0 1.0 sec Time in seconds [0..65535] 22 -0.065904 0.010293 A MIDAS LCL 6A current 23 -0.071692 0.010242 A MIDAS LCL 6B current 24 -1.845312 0.288204 W MIDAS LCL 6A power 25 -2.007376 0.286776 W MIDAS LCL 6B power 30 0.0 1.0 Bit pattern for image types 31 800.0 -2.71276E-02 um Approach LVDT position 32 16.398 1.8221 mm Linear stage LVDT position 33 0.0 3.051804E-04 % F-scan operating point [-100..100 %] 34 0.0 6.103609E-05 Feature vector weight factor [0..4] 35 0.0 1.525902E-05 Linear regression x/y factor 40 0.0 0.164 nm Z DAC set value (closed loop) 41 0.0 3.814 nm X DAC set value (open loop = default) 42 0.0 1.389 nm X DAC set value (closed loop) 43 0.0 3.814 nm Y DAC set value (open loop = default) 44 0.0 1.389 nm Y DAC set value (closed loop) Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 30 3.4.2.3 Catalog Directory This directory contains the catalog object files for the entire volume (= data set): CATINFO.TXT: Description of the contents of the CATALOG directory. DATASET.CAT: PDS data set catalog information about the data set currently being submitted. INST.CAT: PDS instrument catalog information about the MIDAS instrument (likely to be the same in all deliveries, unless updates are needed). INSTHOST.CAT: PDS instrument host catalog information about the Rosetta spacecraft and the mounting relationship of the instruments within the spacecraft; provided by ESA. MISSION.CAT: PDS mission catalog information about the Rosetta mission; provided by ESA. REFERENCE.CAT: PDS reference catalog information about the every journal article, book or other published reference mentioned in the above catalog objects or their components. SOFTWARE.CAT: PDS software catalog information about the software submitted in the data set. TARGET.CAT: PDS target catalog information about the observation target, i.e. comet, asteroid, Earth or Mars; provided by ESA. 3.4.2.4 Index Directory This directory contains the index files summarising all data products in the volume (= data set) by mode, key instrument parameters or mission phase, and organised to facilitate finding the data of interest for a particular scientific question. Information about the observation geometry of the data products are also included here, i.e. spacecraft position and attitude, illumination conditions etc. Information that is not accurately known at the time of delivery and thus will probably be updated later is stored in the index files rather than in the data product labels. INDXINFO.TXT: Description of the contents of the INDEX directory. 3.4.2.4.1 Dataset Index File, index.lbl and index.tab INDEX.LBL: Detached label for the index table INDEX.TAB. The INDEX_TABLE specific object is used to identify and describe the columns of the index table. INDEX.TAB: Index of the data set in tabular format. 3.4.2.4.2 Other Index Files None Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 31 3.4.2.5 Software Directory This directory will not be provided in the data sets. Nevertheless, the source codes (IDL routines) for data calibration, visualization and analysis will be provided in the DOCUMENT directory. 3.4.2.6 Label Directory This directory contains PDS labels and includes files (referenced by a pointer in a PDS label) that are not packaged with the data products or in the data directory. For example, the format descriptions (columns) of the standard and extended housekeeping data products are located in this directory. LABINFO.TXT : Description of the contents of the LABEL directory. 3.4.2.7 Document Directory This directory provides documentation and supplementary and ancillary information to assist in understanding and using the data products in the volume (= data set). The documentation describes the MIDAS instrument as well as the MIDAS data sets and calibration. The MIDAS EAICD is included. According to the PDS standards the documents are present in ASCII format to ensure long-term readability. Document versions in PDF format are also provided in this directory. DOCINFO.TXT : Description of the contents of the DOCUMENT directory. 3.4.2.8 Extras Directory This directory will not be provided in the data sets. 3.4.2.9 Data Directory This directory contains the actual data such as images or tables. PDS labeled data files or data files with detached PDS label files are arranged in a logical subdirectory structure (see section 3.1.4, Data Directory Naming Convention). Format specifications referred to in PDS labels are provided in the LABEL directory. 3.4.2.10 Browse, Geometry and Gazetter Directory These directories are not provided in the data sets. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 32 4 Detailed Interface Specifications 4.1 Structure and Organization Overview 4.1.1 Data Processing Diagram The diagram below shows the MIDAS archive data set production principle: MIDAS data set production MIDAS Setup raw data archive(DDS data) Select rawdata source(s) e.g PC0 data (2 sessions):TLM_0508523_0508602_*.DATTLM_0510911_0510918_*.DAT Define global e.g. volume start and stop time, data set attributes mission phase name and target, ... Data set profile Processing Create emptydata set creates data set directory structureand ingests data independent files(e.g. VOLDESC.CAT, format files, ...) ROSETTA SPICE kernel data pool For each session ingests data labels and files for each Ingest data session within the selected raw data MIDAS archivedata set templates files (session = set of raw data filesbelonging to the same observation) End of loop Validation MIDAS archive Cleanup removes unused format files and data set data set labels as well as empty directories Validate data validation with several tools data set (e.g. PVV, NASA PDS Tools, ...) End Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 33 4.1.2 Data Product Preparation The preparation of the different data products is carried out in two different ways, depending on the data type: Plain TM packet copy: The archive data files are generated from the plain DDS raw data telemetry packets with the DDS header removed (e.g. housekeeping data files). Derived data products: At least one additional processing step is required in order to generate the data files (e.g. image data files). The following table gives an overview of the MIDAS data products and the associated type of data preparation (session = set of raw data files belonging to the same observation and/or time range): Data Type Mnemonic Data Processing Table Type Housekeeping Data HK1, HK2 plain TM copy; one file per session BINARY Frequency Scan Data FSC plain TM copy; one file per scan BINARY Single Point Approach Data SPA plain TM copy; one file per approach BINARY Single Point Sampling Data SPS plain TM copy; one file per scan BINARY Line Scan Data LIN plain TM copy; one file per line BINARY Image Scan Data IMG converted to BCR format; one file BINARY per image and image data type Feature Vector Data ROI plain TM copy; one file per task BINARY Event Data EVN converted to ASCII; one file per ASCII session Cantilever Utilisation History CAH extracted from cumulative cantilever ASCII history file; one file per data set Target Utilisation History TGH extracted from cumulative target ASCII history file; one file per data set Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 34 4.2 Data Sets, Definition and Content 4.2.1 Data Set Production According to the ROSETTA Archive Plan there is one separate data set per mission phase in the pre-cometary phase. The PDS formatted MIDAS data archives are delivered at the latest 6 months after the end of the single mission phases. After arriving at the comet, a continuous data flow is anticipated (mission phases approach, Lander delivery and relay, escort, extended mission), and the PDS formatted MIDAS data sets are delivered in 3-month intervals. The last proprietary, validation and archive preparation period of 6 months starts at the end of the Rosetta mission. The following data sets are provided (as defined in the ROSETTA Mission Calendar): Mission Phase Start Date End Date Date Set ID GROUND 2000-01-01 2004-03-01 data set selection ongoing LAUNCH 2004-03-02 2004-03-04 no data COMMISSIONING 2004-03-052004-09-062004-06-062004-10-16RO-CAL-MIDAS-3-CVP-FULL-V2.0 CRUISE 1 2004-06-07 2004-09-05 no data EARTH SWING-BY 1 2004-10-17 2005-04-04 RO-X-MIDAS-3-EAR1-PC0-V2.0 CRUISE 2 2005-04-05 2006-07-28 RO-X-MIDAS-3-CR2-PC1-2-V2.0 MARS SWING-BY 2006-07-29 2007-05-28 RO-X-MIDAS-3-MARS-PC3-5-V2.0 CRUISE 3 2007-05-29 2007-09-12 no data EARTH SWING-BY 2 2007-09-13 2008-01-27 RO-X-MIDAS-3-EAR2-PC6-7-V2.0 CRUISE 4-1 2008-01-28 2008-08-03 RO-X-MIDAS-3-CR4A-PC8-V2.0 STEINS FLY-BY 2008-08-04 2008-10-05 no data CRUISE 4-2 2008-10-06 2009-09-13 RO-X-MIDAS-3-CR4B-PC9-V2.0 EARTH SWING-BY 3 2009-09-14 2009-12-13 RO-X-MIDAS-3-EAR3-PC10-V2.0 CRUISE 5 2009-12-14 2010-05-16 RO-X-MIDAS-3-CR5-PC12-V2.0 LUTETIA FLY-BY 2010-05-17 2010-09-03 RO-A-MIDAS-3-AST2-LUTE-V2.0 RENDEZVOUSMANEUVER 1 2010-09-04 2011-06-07 no data CRUISE 6 2011-06-08 2014-01-20 no data PRELANDING 2014-01-21 2014-11-18 RO-D-MIDAS-3-PRL-SAMPLES-V2.0 COMET ESCORT 1 2014-11-19 2015-03-10 RO-C-MIDAS-3-ESC1-SAMPLES-V2.0 COMET ESCORT 2 2015-03-11 2015-06-30 RO-C-MIDAS-3-ESC2-SAMPLES-V2.0 COMET ESCORT 3 2015-07-01 2015-10-20 RO-C-MIDAS-3-ESC3-SAMPLES-V2.0 COMET ESCORT 4 2015-10-21 2016-01-12 RO-C-MIDAS-3-ESC4-SAMPLES-V2.0 ROSETTA EXTENS. 1 2016-01-13 2016-04-05 RO-C-MIDAS-3-EXT1-SAMPLES-V2.0 ROSETTA EXTENS. 2 2016-04-06 2016-06-28 RO-C-MIDAS-3-EXT2-SAMPLES-V2.0 ROSETTA EXTENS. 3 2016-06-29 2016-09-30 RO-C-MIDAS-3-EXT3-SAMPLES-V2.0 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 35 4.2.2 Instrument Mode Definition The MIDAS operational concept is based on tasks, rather than on modes. In order to perform a scientific observation, several tasks are executed one after the other. Therefore it is not very meaningful to describe a full observation (from instrument switch-on to switch-off) with a single mode identifier. Nevertheless, two rudimental instrument "modes" have been identified: INSTRUMENT_MODE_ID INSTRUMENT_MODE_DESC NORMAL Data generated by S/W stored in on-board EEPROM. MODIFIED_NORMAL Data generated by temporarily patched on-board S/W. 4.2.3 Data Quality Definition The following table lists the data quality identifiers and data quality descriptions used in the MIDAS data labels: DATA_QUALITY_ID DATA_QUALITY_DESC -1 Data quality information is not supplied. 0 Bad data. 1 Use with caution. 2 Data ok. 4.2.4 Geometry Information The following geometry keywords are used in the MIDAS data labels: Geometry Keyword Comment SC_SUN_POSITION_VECTOR "N/A" for ground based data sets. SC_TARGET_POSITION_VECTOR "N/A" for ground based data sets. SC_TARGET_VELOCITY_VECTOR "N/A" for ground based data sets. SPACECRAFT_ALTITUDE "N/A" for ground based and pre-comet data sets. SUB_SPACECRAFT_LATITUDE "N/A" for ground based and pre-comet data sets. SUB_SPACECRAFT_LONGITUDE "N/A" for ground based and pre-comet data sets. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 36 4.2.5 Mission Specific Keywords The following mission specific keywords (namespace ROSETTA) are used in the MIDAS data labels: Mission Specific Keyword Data Values Description Position of the linear stage given by the linear LVDT position MIDAS_LIN_STAGE_POS -9.00 - +9.00 sensor. For a description of therelationship between tip number and linear stage position see [9], chapter 4.2.2. "DYNAMIC" MIDAS_SCANNING_MODE "CONTACT" Data acquisition mode. "MAGNETIC" "ZS:Z_SET_VAL" "AC:CANT_AC_MON" "AR:CANT_AC_RET" "PH:CANT_PH_MON" "DC:CANT_DC_MON" "XH:X_HV_MON" "YH:Y_HV_MON" "ZH:Z_HV_MON" Image scans data type. "XP:X_POS_MON" MIDAS_SCAN_DATA_TYPE "YP:Y_POS_MON" A detailed description of the "ZP:Z_POS_MON" different data types is given in "XE:X_ERR_MON" chapter 2.5, "Image Scan Data". "YE:Y_ERR_MON" "ZE:Z_ERR_MON" "S1:DAQ_STATUS_1" "S2:DAQ_STATUS_2" "M1:CANT_AC_MAG1" "M2:CANT_AC_MAG2" "M3:CANT_AC_MAG3" MIDAS_SCAN_DIRECTION {M,X,Y}M = MAIN_X, MAIN_YX = X_LTOH, X_HTOLY = Y_LTOH, Y_HTOLMain, X and Y image and linescan direction. LTOH indicatesscans from low to high piezocontrol voltages (default). HTOLdenotes the opposite direction. Start coordinates (origin) of an (X,Y)MIDAS_SCAN_START_XYX = 0..65535Y = 0..65535image, line or single point scanrelative to the X/Y stage origin.The coordinates are given in DAC(digital-analogue converter) set values. (X,Y)MIDAS_SCAN_STOP_XYX = 0..65535Y = 0..65535End coordinates of an image, line,or single point scan relative to theX/Y stage origin. The coordinatesare given in DAC set values. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 37 Selected scan segment. The correlation between target number MIDAS_SEGMENT_NUMBER 0..1023 and segment number is described in chapter 2.5, "Target Utilisation History". "TGZ02""TGX01"MIDAS_TARGET_NAME"TGT01""SILICON""SOLGEL"Name of scan target. TGZ02,TGX01 and TGT01 are used for(re-)calibration of the scannerhead (see chapter 2.5.3). Siliconand SOLGEL targets are used forduct collection. Selected scan target. The correlation between target number MIDAS_TARGET_NUMBER 1..64 and segment number is described in chapter 2.5, "Target Utilisation History". "CALIBRATION" Type of scan target. Plain silicon MIDAS_TARGET_TYPE "PLAIN SILICON" and SOLGEL coated targets are "SOLGEL COATED" used for dust collection. Selected scan cantilever. For a description of the relationship MIDAS_TIP_NUMBER 1..16 between tip number and linear stage position see [9], chapter 4.2.2. 4.2.6 Astronomical Targets vs. MIDAS Targets The term "Target" is used both to refer to the MIDAS dust collection targets (also known as scan targets or facets) and the astronomical target which may be a planet, satellite, ring, region, feature, asteroid or comet. Astronomical Targets are referenced in the following context: Astronomical target attributes in PDS labels (TARGET_NAME, TARGET_TYPE, SC_TARGET_POSITION_VECTOR and SC_TARGET_VELOCITY_VECTOR) Catalog files INSTHOST.CAT, MISSION.CAT and TARGET.CAT DATA_SET_TARGET object in dataset catalog (DATASET.CAT) MIDAS Targets are referred to by Mission specific keywords in PDS labels (ROSETTA:MIDAS_TARGET_NAME, ROSETTA:MIDAS_TARGET_NUMBER and ROSETTA:MIDAS_TARGET_TYPE) Target column of image list provided in DATASET.CAT and targets in INST.CAT Event table in MIDAS target history files (/DATA/TGH*.LBL, TGH_STRUCTURE.FMT) Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 38 4.3 Data Product Design 4.3.1 Data Product Design - Standard Housekeeping Data The MIDAS standard housekeeping data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/HK1 File naming: HK1_yydddhh_yydddhh.DAT File structure: /LABEL/HK1_STRUCTURE.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A typical PDS label for a standard housekeeping data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 56 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 39 DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* DATA FILE POINTER(S) */ ^HK1_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = HK1_TABLE INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 28 ROW_BYTES = 56 NAME = "MIDAS standard HK" ^STRUCTURE = "HK1_STRUCTURE.FMT" END_OBJECT = HK1_TABLE END The standard housekeeping data file structure is defined as follows: /* HK1 FRAME STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 40 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "INSTRUMENT_MODE" DESCRIPTION = "Instrument mode status word." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 21 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "BASEPLATE_TEMPERATURE" DESCRIPTION = "AFM base plate temperature sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 23 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PREAMPLIFIER_TEMPERATURE" DESCRIPTION = "Cantilever preamplifier temperature readout." DATA_TYPE = MSB_INTEGER START_BYTE = 25 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 41 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CONVERTER_TEMPERATURE" DESCRIPTION = "Power converter temperature readout." DATA_TYPE = MSB_INTEGER START_BYTE = 27 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CSSC_XREF_TEMPERATURE" DESCRIPTION = "Capacitive sensor X reference temperature." DATA_TYPE = MSB_INTEGER START_BYTE = 29 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CSSC_YREF_TEMPERATURE" DESCRIPTION = "Capacitive sensor Y reference temperature." DATA_TYPE = MSB_INTEGER START_BYTE = 31 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "INLET_TEMPERATURE" DESCRIPTION = "Temperature measured at the dust inlet." DATA_TYPE = MSB_INTEGER START_BYTE = 33 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.01143 UNIT = KELVIN END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VOLTAGE_MONITOR_P05" DESCRIPTION = "+5V voltage monitor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 35 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.00030518 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VOLTAGE_MONITOR_P15" DESCRIPTION = "+15V voltage monitor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 37 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.00091706 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VOLTAGE_MONITOR_N15" DESCRIPTION = "-15V voltage monitor readout." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 42 DATA_TYPE = MSB_INTEGER START_BYTE = 39 BYTES = 2 OFFSET = 0.0 SCALING_FACTOR = 0.00091706 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIGITAL_STATUS_1" DESCRIPTION = "Digital lines status word #1." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 41 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIGITAL_STATUS_2" DESCRIPTION = "Digital lines status word #2." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 43 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIGITAL_STATUS_3" DESCRIPTION = "Digital lines status word #3." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 45 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIGITAL_STATUS_4" DESCRIPTION = "Digital lines status word #4." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 47 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DIGITAL_STATUS_5" DESCRIPTION = "Digital lines status word #5." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 49 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ADC_OVERFLOW_FLAGS" DESCRIPTION = "Analog-Digital Converter overflow flags." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 51 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CRC16_CHECKSUM" DESCRIPTION = "Telemetry packet checksum (CRC 16)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 55 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 43 4.3.2 Data Product Design - Extended Housekeeping Data The MIDAS extended housekeeping data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/HK2 File naming: HK2_yydddhh_yydddhh.DAT File structure: /LABEL/HK2_STRUCTURE.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A typical PDS label for an extended housekeeping data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 524 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 44 /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* DATA FILE POINTER(S) */ ^HK2_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = HK2_TABLE INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 259 ROW_BYTES = 524 NAME = "MIDAS extended HK" ^STRUCTURE = "HK2_STRUCTURE.FMT" END_OBJECT = HK2_TABLE END The extended housekeeping data file structure is defined as follows: /* HK2 FRAME STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 45 OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U_CAN_RMS" DESCRIPTION = "Cantilever AC signal readout." DATA_TYPE = MSB_INTEGER START_BYTE = 21 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U_CAN_AMP_DC" DESCRIPTION = "Cantilever DC signal readout." DATA_TYPE = MSB_INTEGER START_BYTE = 23 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U_CAN_PHASE" DESCRIPTION = "Cantilever phase signal readout." DATA_TYPE = MSB_INTEGER START_BYTE = 25 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 46 BYTES = 2 OFFSET = 2.74662E-003 SCALING_FACTOR = 5.49325E-003 UNIT = deg END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APP_POS_MON" DESCRIPTION = "Approach position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 27 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_POS_MON" DESCRIPTION = "Linear stage position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 29 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_PR_OUT" DESCRIPTION = "X piezo control loop offset error readout." DATA_TYPE = MSB_INTEGER START_BYTE = 31 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_PR_OUT" DESCRIPTION = "Y piezo control loop offset error readout." DATA_TYPE = MSB_INTEGER START_BYTE = 33 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_PR_OUT" DESCRIPTION = "Z piezo control loop offset error readout." DATA_TYPE = MSB_INTEGER START_BYTE = 35 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XPIEZO_VSENS_OUT" DESCRIPTION = "X piezo high voltage monitor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 37 BYTES = 2 OFFSET = 1.00002E+002 SCALING_FACTOR = 4.27253E-003 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "YPIEZO_VSENS_OUT" DESCRIPTION = "Y piezo high voltage monitor readout." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 47 DATA_TYPE = MSB_INTEGER START_BYTE = 39 BYTES = 2 OFFSET = 1.00002E+002 SCALING_FACTOR = 4.27253E-003 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XPIEZO_POS" DESCRIPTION = "X piezo position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 41 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "YPIEZO_POS" DESCRIPTION = "Y piezo position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 43 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ZPIEZO_POS" DESCRIPTION = "Z piezo position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 45 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ZPIEZO_VSENS_OUT" DESCRIPTION = "Z piezo high voltage monitor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 47 BYTES = 2 OFFSET = 1.00002E+002 SCALING_FACTOR = 4.27253E-003 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ABORT_FULLSCAN" DESCRIPTION = "Flag, set if ABORT command was sent during a full scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 49 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ABORT_FUNCTION" DESCRIPTION = "Flag, set if ABORT command was sent during an active task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 51 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ABORT_LINE" DESCRIPTION = "Flag, set if Z DAC value reached its lower limit (- 10V)." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 48 START_BYTE = 53 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ABORT_POINT" DESCRIPTION = "Flag, set if Z DAC value reached its upper limit (+10V)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 55 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AC_GAIN" DESCRIPTION = "Gain level for cantilever AC signal amplifier (0-7)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 57 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_BACKW_STARTED" DESCRIPTION = "Flag, set if backward approach task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 59 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_FINISHED" DESCRIPTION = "Flag, set if segment surface was detected during forward approach." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 61 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_FINE_STEP" DESCRIPTION = "Flag, set if fine steps are applied during approach." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 63 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_ON_MAX_POS" DESCRIPTION = "Flag, set if max. position was reached during an approach task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 65 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_ON_MIN_POS" DESCRIPTION = "Flag, set if min. position was reached during an approach task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 67 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_POSITION" DESCRIPTION = "Approach position sensor readout during an approach task." DATA_TYPE = MSB_INTEGER START_BYTE = 69 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 49 OBJECT = COLUMN NAME = "APPR_POS_SET" DESCRIPTION = "Approach position set value for next forward approach step." DATA_TYPE = MSB_INTEGER START_BYTE = 71 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_STARTED" DESCRIPTION = "Flag, set if forward approach task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 73 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_POS_ABS" DESCRIPTION = "Approach position set value for absolute approach movement." DATA_TYPE = MSB_INTEGER START_BYTE = 75 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_DIR" DESCRIPTION = "Flag, set if approach direction is towards surface." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 77 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_ABS_STARTED" DESCRIPTION = "Flag, set if absolute approach positioning task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 79 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_TIMO_CNT" DESCRIPTION = "Holds remaining seconds until approach timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 81 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AVERAGE" DESCRIPTION = "Average factor for Z strain gauge signal measurement." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 83 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANTILEVER" DESCRIPTION = "Selected cantilever of current cantilever block (0- 7)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 85 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 50 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_BLOCK" DESCRIPTION = "Number of selected cantilever block (1 or 2)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 87 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_SIGNAL" DESCRIPTION = "Current cantilever signal measured during scan." DATA_TYPE = MSB_INTEGER START_BYTE = 89 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_X_CYCLE_STARTED" DESCRIPTION = "Flag, set if X position sensor calibration task has started." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 91 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_X_CYCLE_FINISHED" DESCRIPTION = "Flag, set if X position sensor calibration task has completed successfully." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 93 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_Y_CYCLE_STARTED" DESCRIPTION = "Flag, set if Y position sensor calibration task has started." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 95 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_Y_CYCLE_FINISHED" DESCRIPTION = "Flag, set if Y position sensor calibration task has completed successfully." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 97 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAP_SENS_EN" DESCRIPTION = "Flag, set if X/Y position sensor control is enabled." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 99 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_CYCLES" DESCRIPTION = "X/Y position sensor calibration cycle counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 101 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_TIMO_CNT" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 51 DESCRIPTION = "Holds remaining seconds until X/Y position sensor calibration timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 103 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COR_TAB" DESCRIPTION = "Selected correction table (0=norm temp, 1=high temp, 2=low temp)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 105 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CO_CMD" DESCRIPTION = "Last checkout (technical) command which has been executed on-board." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 107 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CUR_LIN_POS" DESCRIPTION = "Current linear position sensor value measured during linear stage movement." DATA_TYPE = MSB_INTEGER START_BYTE = 109 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CYCLES" DESCRIPTION = "Holds number of Z increments and decrements during single point scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 111 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DATA_TYPE" DESCRIPTION = "Image scan data type (0=z-topography, 1=z-error, ...)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 113 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DC_GAIN" DESCRIPTION = "Gain level for cantilever DC signal amplifier (0-7)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 115 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DC_PULSEWIDTH" DESCRIPTION = "Approach DC motor pulse width set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 117 BYTES = 2 OFFSET = 2.10000E+001 SCALING_FACTOR = 4.20000E+001 UNIT = usec END_OBJECT = COLUMN OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 52 NAME = "DECR_APPR_POS" DESCRIPTION = "Flag, set if approach advances to next position." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 119 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DSCAN_RAND_AMPL" DESCRIPTION = "Dummy scan random noise amplitude set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 121 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_APPR_POS" DESCRIPTION = "Approach position signal decrement used in coarse approach steps." DATA_TYPE = MSB_INTEGER START_BYTE = 123 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_OP_PERC" DESCRIPTION = "Allowed deviation from cantilever signal operating point in % of resonance amplitude." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 125 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_OP_AMPL" DESCRIPTION = "Allowed deviation from cantilever signal operating point (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 127 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DUMMY_FULL_SCAN" DESCRIPTION = "Flag, set if dummy image scan task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 129 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EXC_LEV" DESCRIPTION = "Gain level for cantilever excitation (0-7)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 131 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DSCAN_SINE_AMPL" DESCRIPTION = "Dummy scan sine amplitude set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 133 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 53 NAME = "DSCAN_ZERO_OFFS" DESCRIPTION = "Dummy scan zero offset set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 135 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DSCAN_GRAD_SINE" DESCRIPTION = "Dummy scan X/Y gradient and sine period set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 137 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SCAN_NO_THRES" DESCRIPTION = "Flag, set if threshold amplitude has not been found during frequency scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 139 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SCAN_CYCLE" DESCRIPTION = "Current scan cycle of the automatic frequency scan task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 141 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_STUCK_CNT" DESCRIPTION = "Number of times the approach stuck event will be ignored." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 143 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SCAN_STARTED" DESCRIPTION = "Flag, set if the automatic frequency scan task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 145 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SCAN_FINISHED" DESCRIPTION = "Flag, set if the automatic frequency scan task has completed." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 147 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_STEP" DESCRIPTION = "Nominal frequency scan step increment." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 149 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_STEP_HI" DESCRIPTION = "Frequency scan step increment for threshold detection." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 54 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 151 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FULLSCAN_STARTED" DESCRIPTION = "Flag, set if the image scan task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 153 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GAIN_STEP" DESCRIPTION = "Gain control increment/decrement for X/Y position sensor calibration." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 155 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_PERIOD" DESCRIPTION = "Extended HK report update period in seconds." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 157 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_TC" DESCRIPTION = "Last received private telecommand (MSB=type, LSB=subtype)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 159 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_MOVE_STARTED" DESCRIPTION = "Flag, set if a linear stage movement task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 161 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_MOVE_FINISHED" DESCRIPTION = "Flag, set if a linear stage movement task has completed." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 163 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEST_LIN_LVDT" DESCRIPTION = "Flag, set if linear stage position sensor is evaluated during task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 165 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINE_SCAN_CNT" DESCRIPTION = "Number of scanned image lines so far." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 167 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 55 OBJECT = COLUMN NAME = "LINE_NUM_STEPS" DESCRIPTION = "Total number of image lines to be scanned." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 169 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINESCAN_DONE" DESCRIPTION = "Flag, set if the line scan task has completed." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 171 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINESCAN_STARTED" DESCRIPTION = "Flag, set if the line scan task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 173 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINMOVE_TIMO_CNT" DESCRIPTION = "Holds remaining seconds until linear stage timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 175 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINMOVE_TIMO" DESCRIPTION = "Linear stage movement timeout set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 177 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAIN_SCAN_CNT" DESCRIPTION = "Number of scanned pixels in main scan direction (within line) so far." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 179 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAIN_SCAN_DIR" DESCRIPTION = "Main dummy/image/line scan direction (0=X, 1=Y)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 181 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAIN_NUM_STEPS" DESCRIPTION = "Total number of pixels in main scan direction." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 183 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAGN_RETRACT_DIST" DESCRIPTION = "Z retraction distance for magnetic mode." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 185 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 56 OBJECT = COLUMN NAME = "MSUB_CYCLES" DESCRIPTION = "Maximum number of scan cycles per single_point() function call." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 187 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAX_CYCLES" DESCRIPTION = "Maximum number of scan cycles allowed for a single point." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 189 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAX_CAL_CYCLES" DESCRIPTION = "Maximum number of X/Y position sensor calibration cycles." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 191 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_APPR_DIR" DESCRIPTION = "Approach movement direction during last approach task." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 193 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NO_OF_FSCANS" DESCRIPTION = "Number of frequency sweep cycles for the automatic frequency scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 195 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OFFS_STEP" DESCRIPTION = "Offset control increment/decrement for X/Y position sensor calibration." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 197 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_POINT_PERC" DESCRIPTION = "Threshold value of cantilever signal in % of resonance amplitude for data acquisition." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 199 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_POINT_AMPL" DESCRIPTION = "Threshold value of cantilever signal for data acquisition (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 201 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 57 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_UP" DESCRIPTION = "Cantilever signal threshold value upper limit (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 203 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_LO" DESCRIPTION = "Cantilever signal threshold value lower limit (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 205 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PERCENT_OP_AMPL" DESCRIPTION = "% of resonance amplitude at which to set the operating frequency (+=right, -=left)." DATA_TYPE = MSB_INTEGER START_BYTE = 207 BYTES = 2 OFFSET = 1.52590E-003 SCALING_FACTOR = 3.05180E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PARAMETER" DESCRIPTION = "Parameter part of last executed parameter command." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 209 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PARAMETER_CMD" DESCRIPTION = "Command code of last executed parameter command." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 211 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PULSE_DELAY" DESCRIPTION = "Pulse delay mode for linear stage motor (0-3)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 213 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PULSEWIDTH" DESCRIPTION = "Piezo motor driver pulse width." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 215 BYTES = 2 OFFSET = 2.10000E+001 SCALING_FACTOR = 4.20000E+001 UNIT = usec END_OBJECT = COLUMN OBJECT = COLUMN NAME = "REF_SEARCH_STARTED" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 58 DESCRIPTION = "Flag, set if wheel reference point search has started." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 217 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RELAY_STATUS" DESCRIPTION = "Power relay status flags." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 219 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RESONANCE_AMPL" DESCRIPTION = "Cantilever signal amplitude at resonance frequency." DATA_TYPE = MSB_INTEGER START_BYTE = 221 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RETRACT_DIST" DESCRIPTION = "Z retraction before advancing to next scan position." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 223 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_MODE" DESCRIPTION = "Scanning mode (0=dynamic, 1=contact, 2=magnetic)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 225 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_ERROR_CNT" DESCRIPTION = "Holds the number of pixels where the max. number of scan cycles was exceeded." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 227 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SEARCH_ALGOR" DESCRIPTION = "Cantilever resonance frequency search mode." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 229 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SEND_CO_FR" DESCRIPTION = "Flag, set if checkout frame is sent periodically." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 231 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DST_SELECT" DESCRIPTION = "Data set selection for cleanup/transfer (bit 15 = oldest, bit 14 = newest)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 233 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 59 OBJECT = COLUMN NAME = "SEGMENT_PULSES" DESCRIPTION = "Wheel encoder ticks for segment selection." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 235 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SEGMENT_SEARCH_STARTED" DESCRIPTION = "Flag, set if segment search task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 237 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SEGMENT_FOUND" DESCRIPTION = "Flag, set if the wheel segment search has completed successfully." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 239 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SEGMENT_NO" DESCRIPTION = "Wheel segment selection set value (0-1023)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 241 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SET_LIN_POS" DESCRIPTION = "Linear stage position sensor value for absolute positioning (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 243 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SET_LIN_POS_ABS" DESCRIPTION = "Linear stage position sensor set value for absolute positioning." DATA_TYPE = MSB_INTEGER START_BYTE = 245 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "REGULAR_EXT_CODE" DESCRIPTION = "Flag, set if the extended program code area is entered every millisecond." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 247 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SHUT_CLOSE_STARTED" DESCRIPTION = "Flag, set if the shutter closing task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 249 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 60 OBJECT = COLUMN NAME = "SHUT_OPEN_STARTED" DESCRIPTION = "Flag, set if the shutter opening task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 251 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SHUTTER_TIMO_CNT" DESCRIPTION = "Holds remaining seconds until a shutter movement timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 253 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SINGLE_F_SCAN" DESCRIPTION = "Flag, set if the single frequency scan is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 255 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SURF_DETECTED" DESCRIPTION = "Flag, set if surface was detected during approach." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 257 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TECH_MODE" DESCRIPTION = "Flag, set if technical mode commands are enabled." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 259 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIMEOUTS" DESCRIPTION = "Timeout status flags." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 261 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIP_NO" DESCRIPTION = "Cantilever selection set value (0-15)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 263 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U_MAX" DESCRIPTION = "Maximum cantilever signal amplitude detected during frequency scan so far." DATA_TYPE = MSB_INTEGER START_BYTE = 265 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VREF_ACC" DESCRIPTION = "X/Y position sensor calibration accuracy." DATA_TYPE = MSB_INTEGER START_BYTE = 267 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 61 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VXREF1" DESCRIPTION = "X position sensor reference voltage 1." DATA_TYPE = MSB_INTEGER START_BYTE = 269 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VXREF2" DESCRIPTION = "X position sensor reference voltage 2." DATA_TYPE = MSB_INTEGER START_BYTE = 271 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VYREF1" DESCRIPTION = "Y position sensor reference voltage 1." DATA_TYPE = MSB_INTEGER START_BYTE = 273 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VYREF2" DESCRIPTION = "Y position sensor reference voltage 2." DATA_TYPE = MSB_INTEGER START_BYTE = 275 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAIT_CYCLE" DESCRIPTION = "Flag, set if a wait cycle is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 277 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAITING_TIME" DESCRIPTION = "Holds number of seconds until the wait cycle completes." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 279 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAX_ACTUATOR" DESCRIPTION = "AFM base plate lock mechanism actuator selection (0=actuator 1, 1= actuator 2)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 281 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 62 OBJECT = COLUMN NAME = "WAXACT_TIMO_CNT" DESCRIPTION = "Holds number of seconds until a base plate release task timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 283 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAXACT_STATUS" DESCRIPTION = "AFM base plate lock mechanism actuator heating status (1=main, 2=red, 4=extended)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 285 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAXACT_EXT_CNT" DESCRIPTION = "Holds number of seconds until base plate actuator extended heating cycle completes." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 287 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WAXACT_TIMO" DESCRIPTION = "AFM base plate lock mechanism actuator heating timeout set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 289 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WHEEL_TIMO_CNT" DESCRIPTION = "Holds number of seconds until a wheel segment selection timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 291 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_ORIGIN" DESCRIPTION = "X offset of image with respect to the X/Y table origin." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 293 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_NUM_STEPS" DESCRIPTION = "Number of scan pixels in X direction (n times 32, n=1-16)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 295 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_SCAN_DIRECTION" DESCRIPTION = "Flag, indicates X scan direction (0=low to high DAC voltage, 1= high to low)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 297 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_STEP_SIZE" DESCRIPTION = "X scan step set value in DAC units." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 63 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 299 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XY_ACTUATOR" DESCRIPTION = "X/Y table lock mechanism actuator selection (0= x- actuator, 1= y-actuator)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 301 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XYACT_MAIN_STARTED" DESCRIPTION = "Flag, set if heating cycle of the main X or Y actuator is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 303 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XYACT_RED_STARTED" DESCRIPTION = "Flag, set if heating cycle of the redundant X or Y actuator is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 305 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XYACT_TIMO" DESCRIPTION = "X/Y table lock mechanism actuator heating timeout set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 307 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XYACT_TIMO_CNT" DESCRIPTION = "Holds number of seconds until an X/Y table release timeout occurs." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 309 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_STEP_SIZE" DESCRIPTION = "Y scan step set value in DAC units." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 311 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_ORIGIN" DESCRIPTION = "Y offset of image with respect to the X/Y table origin." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 313 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_SCAN_DIRECTION" DESCRIPTION = "Flag, indicates Y scan direction (0=low to high DAC voltage, 1= high to low)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 315 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 64 OBJECT = COLUMN NAME = "Y_NUM_STEPS" DESCRIPTION = "Number of scan pixels in Y direction (n times 32, n=1-16)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 317 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_STEP_SIZE" DESCRIPTION = "Z scan step set value in DAC units." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 319 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_OVFL_FLAGS" DESCRIPTION = "ADC channel overflow flags." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 321 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_DC_CONTACT" DESCRIPTION = "Maximum allowed cantilever DC value change during surface approach." DATA_TYPE = MSB_INTEGER START_BYTE = 325 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_SIGNAL_RETR" DESCRIPTION = "Cantilever signal at retracted position (magnetic mode)." DATA_TYPE = MSB_INTEGER START_BYTE = 327 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DST_INFO" DESCRIPTION = "Data set control status word (0-7=ID, 8-11=status, 12-15=transfer mode)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 329 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LONG_Z" DESCRIPTION = "Last Z piezo position set value during scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 331 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_GAIN" DESCRIPTION = "Gain level for Z position sensor (strain gauge)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 333 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 65 OBJECT = COLUMN NAME = "GC_X" DESCRIPTION = "X/Y position sensor X gain control value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 335 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_Y" DESCRIPTION = "X/Y position sensor Y gain control value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 337 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OFC_X" DESCRIPTION = "X/Y position sensor X offset control value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 339 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OFC_Y" DESCRIPTION = "X/Y position sensor Y offset control value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 341 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_ALGOR" DESCRIPTION = "Scan algorithm (1=window detection, 2=p-controller, else threshold detection)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 343 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIRST_THRES_DET" DESCRIPTION = "Flag, set for first threshold detection cycle at current scan location." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 345 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DUST_FLUX" DESCRIPTION = "GIADA dust flux monitor value readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 347 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_POINT_PCONTROL" DESCRIPTION = "P-controller (scanning) operating point value (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 349 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_POINT_PCONTR_PERC" DESCRIPTION = "P-controller (scanning) operating point set value in % of resonance amplitude." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 66 START_BYTE = 351 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PCONTR_KC" DESCRIPTION = "P-controller (scanning) gain control set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 353 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PCONTR_ACTIVE" DESCRIPTION = "Flag, indicates that the P-controller is active during scanning." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 355 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_EVENT" DESCRIPTION = "Identifier of last generated on-board event." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 357 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_DAC_VAL" DESCRIPTION = "Last DAC value applied to the X piezo of the scanner head." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 359 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_DAC_VAL" DESCRIPTION = "Last DAC value applied to the Y piezo of the scanner head." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 361 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_DAC_VAL" DESCRIPTION = "Last DAC value applied to the Z piezo of the scanner head." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 363 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_SETTLE_TIME" DESCRIPTION = "Z piezo settling time in milliseconds before advancing to next scan position." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 365 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "XY_SETTLE_TIME" DESCRIPTION = "X/Y piezo settling time in milliseconds before advancing to next scan position." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 367 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 67 OBJECT = COLUMN NAME = "DUST_FLUX_MIN" DESCRIPTION = "GIADA dust flux monitor lower limit (exposure time increases when exceeded)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 369 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DUST_FLUX_MAX" DESCRIPTION = "GIADA dust flux monitor upper limit (exposure time decreases when exceeded)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 371 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SCAN_MODE" DESCRIPTION = "Flag, set if threshold detection after frequency scan is skipped." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 373 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_THRES_HI" DESCRIPTION = "Cantilever operating point frequency (high word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 375 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 4.57703E+001 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_THRES_LO" DESCRIPTION = "Cantilever operating point frequency (low word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 377 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SYNTH" DESCRIPTION = "Last output value of frequency synthesizer." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 379 BYTES = 4 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK1_PERIOD" DESCRIPTION = "Standard HK report update period in seconds." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 383 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_HI" DESCRIPTION = "Last output value of frequency synthesizer (high word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 385 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 68 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 4.57703E+001 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_LO" DESCRIPTION = "Last output value of frequency synthesizer (low word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 387 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FRES_HI" DESCRIPTION = "Detected cantilever resonance frequency (high word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 389 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 4.57703E+001 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FRES_LO" DESCRIPTION = "Detected cantilever resonance frequency (low word)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 391 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "READ_ANALOG" DESCRIPTION = "Flag, set if analog channels readout is performed periodically" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 393 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_SGL_START" DESCRIPTION = "Frequency scan start value of current cycle." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 395 BYTES = 4 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_INC" DESCRIPTION = "Frequency scan increment value between cycles (256 times F_STEP)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 399 BYTES = 4 OFFSET = 0.00000E+000 SCALING_FACTOR = 6.98253E-004 UNIT = Hz END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DC_AMPL_SET" DESCRIPTION = "DC threshold value for contact mode scanning." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 69 DATA_TYPE = MSB_INTEGER START_BYTE = 403 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHECK_DC_SIGNAL" DESCRIPTION = "Flag, set if checking of the cantilever DC signal during approach is enabled." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 405 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U_CANT_DC_START" DESCRIPTION = "Cantilever DC signal value at the beginning of the coarse approach." DATA_TYPE = MSB_INTEGER START_BYTE = 407 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CONTACT" DESCRIPTION = "Flag, set if surface contact has occurred during coarse approach." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 409 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AUTO_F_ADJUST" DESCRIPTION = "Flag, set if frequency adjustment is enabled during image scan." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 411 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WHEEL_COUNTS" DESCRIPTION = "Remaining wheel encoder counts until segment is reached." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 413 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PULSE_APPLIED" DESCRIPTION = "Flag, set if an approach pulse has been applied." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 415 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_APPR_POSITION" DESCRIPTION = "Last approach position used for checking the approach movement." DATA_TYPE = MSB_INTEGER START_BYTE = 417 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 70 OBJECT = COLUMN NAME = "MOVEMENT_CHECKED" DESCRIPTION = "Flag, set if the approach movement has been checked." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 419 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CUR_APPROACH_POS" DESCRIPTION = "Current approach position used for checking the approach movement." DATA_TYPE = MSB_INTEGER START_BYTE = 421 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEST_COUNT" DESCRIPTION = "Holds number of milliseconds until approach movement is checked." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 423 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_TEST_COUNT" DESCRIPTION = "Approach movement test interval in milliseconds (set value)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 425 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_OP_AMPL_DC" DESCRIPTION = "Contact mode operating point deviation (calculated)." DATA_TYPE = MSB_INTEGER START_BYTE = 427 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_OP_PERC_DC" DESCRIPTION = "Contact mode operating point deviation in % of cantilever DC set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 429 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_UP_DC" DESCRIPTION = "Contact mode operating point amplitude upper limit." DATA_TYPE = MSB_INTEGER START_BYTE = 431 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OP_LO_DC" DESCRIPTION = "Contact mode operating point amplitude lower limit." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 71 DATA_TYPE = MSB_INTEGER START_BYTE = 433 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_APPR_LVDT" DESCRIPTION = "Minimum approach position change before incrementing the stuck counter." DATA_TYPE = MSB_INTEGER START_BYTE = 435 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_POS_MAX" DESCRIPTION = "Approach sensor position upper limit (set value)." DATA_TYPE = MSB_INTEGER START_BYTE = 437 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_POS_MIN" DESCRIPTION = "Approach sensor position lower limit (set value)." DATA_TYPE = MSB_INTEGER START_BYTE = 439 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FINE_ADJUSTMENT_STARTED" DESCRIPTION = "Flag, set if the approach fine adjustment has started." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 441 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TASK_ACTIVE" DESCRIPTION = "Flag, set if a task is active (e.g. scan)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 443 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "APPR_NUM_PULSES" DESCRIPTION = "Number of approach pulses to apply before testing the approach movement." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 445 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_HIRES_STARTED" DESCRIPTION = "Flag, set if the cantilever high resolution DAQ task is active." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 447 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 72 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_HIRES_TIME" DESCRIPTION = "Time in milliseconds between two cantilever high resolution measurements." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 449 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_HIRES_PKTS" DESCRIPTION = "Total number of cantilever high resolution DAQ data packets." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 451 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_HIRES_TIME_CNT" DESCRIPTION = "Time in milliseconds since last cantilever high resolution measurement." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 453 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_HIRES_PKTS_CNT" DESCRIPTION = "Number of cantilever high resolution DAQ data packets generated so far." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 455 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CAL_STATE" DESCRIPTION = "X/Y position sensor calibration task status word." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 457 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_DATA_PAGE" DESCRIPTION = "Page number for S/W backup/restore." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 459 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_STATUS" DESCRIPTION = "S/W encoding/decoding task status word." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 461 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_SET_ADDR" DESCRIPTION = "Last S/W parameter address." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 463 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_SET_VAL" DESCRIPTION = "Last S/W parameter set value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 465 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 73 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK1_ADDR" DESCRIPTION = "Address of 1st adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 467 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK2_ADDR" DESCRIPTION = "Address of 2nd adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 469 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK3_ADDR" DESCRIPTION = "Address of 3rd adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 471 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK4_ADDR" DESCRIPTION = "Address of 4th adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 473 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK1_VAL" DESCRIPTION = "Value of 1st adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 475 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK2_VAL" DESCRIPTION = "Value of 2nd adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 477 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK3_VAL" DESCRIPTION = "Value of 3rd adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 479 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SW_PAR_HK4_VAL" DESCRIPTION = "Value of 4th adjustable HK parameter readout." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 481 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_MODE" DESCRIPTION = "Feature vector calculation mode." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 483 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 74 OBJECT = COLUMN NAME = "FVECT_LPERC" DESCRIPTION = "Feature detection threshold value in percent of min/max Z value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 485 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_LEVEL" DESCRIPTION = "Calculated feature vector threshold value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 487 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_XMARGIN" DESCRIPTION = "Feature vector X margin (pixel) with respect to selected image." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 489 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_YMARGIN" DESCRIPTION = "Feature vector Y margin (pixel) with respect to selected image." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 491 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_STATUS" DESCRIPTION = "Feature vector calculation status word." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 493 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_NUMPTS" DESCRIPTION = "Required number of points related to a feature in order to be selected." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 495 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_AVG_Z" DESCRIPTION = "Required average height over Z level for a feature in order to be selected." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 497 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FVECT_RATIO" DESCRIPTION = "Required minimum pixels/area ratio for a feature in order to be selected." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 499 BYTES = 2 OFFSET = 0.00000E+000 SCALING_FACTOR = 1.52590E-003 END_OBJECT = COLUMN OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 75 NAME = "FVECT_ZFACTOR" DESCRIPTION = "Feature vector calculation zoom factor in % of feature size." DATA_TYPE = MSB_INTEGER START_BYTE = 501 BYTES = 2 OFFSET = 1.52590E-003 SCALING_FACTOR = 3.05180E-003 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SC_ENABLED" DESCRIPTION = "Flag, set if science data transfer is enabled?" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 503 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "POINT_READY" DESCRIPTION = "Flag, set if cantilever signal is within operating point range." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 505 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "IMAGE_POINT" DESCRIPTION = "Z set value or AC signal difference (magnetic mode) for last DAQ point." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 507 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_TIP_CENTER" DESCRIPTION = "Linear LVDT value to center the currently selected tip within the target." DATA_TYPE = MSB_INTEGER START_BYTE = 509 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "F_ADJUST_AMPL" DESCRIPTION = "Threshold amplitude for automatic f-adjusting during scans." DATA_TYPE = MSB_INTEGER START_BYTE = 511 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = V END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_SPARE_1" DESCRIPTION = "Extended HK report spare word #1." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 513 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_SPARE_2" DESCRIPTION = "Extended HK report spare word #2." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 515 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 76 OBJECT = COLUMN NAME = "HK2_SPARE_3" DESCRIPTION = "Extended HK report spare word #3." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 517 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_SPARE_4" DESCRIPTION = "Extended HK report spare word #4." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 519 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_SPARE_5" DESCRIPTION = "Extended HK report spare word #5." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 521 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HK2_FRAME_CS" DESCRIPTION = "Frame checksum (CRC16), including frame header." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 523 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 77 4.3.3 Data Product Design - Frequency Scan Data The MIDAS frequency scan data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/FSC File naming: FSC_yydddhh_yydddhh_nnn_tt.DAT File structure: /LABEL/FSC_PREFIX.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A frequency scan comprises n (n=1...8) scan cycles of 256 samples each. This data can be mapped to a frequency series table with n rows and 1 column having 256 items. Thus the sampling parameter interval of the table object is 256 times the sampling parameter interval of the associated column object. The frequency range for a given scan is defined by the following keywords of the FREQUENCY_SERIES object: Start frequency: MINIMUM_SAMPLING_PARAMETER Scan cycles: ROWS (total number of samples = 256*ROWS) Frequency step: SAMPLING_PARAMETER_INTERVAL/256 Frequency range: (256*ROWS - 1)*SAMPLING_PARAMETER_INTERVAL/256 A typical PDS label for a frequency scan data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 576 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 78 TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* MISSION SPECIFIC KEYWORDS */ ROSETTA:MIDAS_TIP_NUMBER = /* DATA FILE POINTER(S) */ ^ROW_PREFIX_TABLE = "" ^FREQUENCY_SERIES = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = ROW_PREFIX_TABLE NAME = PKT_HEADER INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 23 ROW_BYTES = 62 ROW_SUFFIX_BYTES = 514 DESCRIPTION = "Frequency scan header table" ^STRUCTURE = "FSC_PREFIX.FMT" END_OBJECT = ROW_PREFIX_TABLE OBJECT = FREQUENCY_SERIES NAME = FREQUENCY_DATA INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 1 ROW_BYTES = 512 ROW_PREFIX_BYTES = 62 ROW_SUFFIX_BYTES = 2 SAMPLING_PARAMETER_NAME = FREQUENCY SAMPLING_PARAMETER_UNIT = HERTZ SAMPLING_PARAMETER_INTERVAL = /* time between rows */ MINIMUM_SAMPLING_PARAMETER = DESCRIPTION = "" OBJECT = COLUMN NAME = DATA_SAMPLES DATA_TYPE = MSB_INTEGER START_BYTE = 1 BYTES = 512 ITEMS = 256 ITEM_BYTES = 2 SAMPLING_PARAMETER_NAME = FREQUENCY SAMPLING_PARAMETER_UNIT = HERTZ SAMPLING_PARAMETER_INTERVAL = /* time between samples */ SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 79 DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN END_OBJECT = FREQUENCY_SERIES END The frequency scan row prefix structure is defined as follows: /* FSC PREFIX STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 80 START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "START_TIME" DESCRIPTION = "S/C clock count at frequency scan start." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 21 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "START_FREQUENCY" DESCRIPTION = "Start value of frequency sweep." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_STEP" DESCRIPTION = "Increment value of frequency sweep." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AC_MAXIMUM" DESCRIPTION = "Detected max. cantilever signal amplitude (up to the current scan cycle)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FREQUENCY_AT_MAX" DESCRIPTION = "Frequency where the maximum signal amplitude was detected." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_SCANS" DESCRIPTION = "Total number of frequency scan cycles." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 81 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_CYCLE" DESCRIPTION = "Current scan cycle number." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 39 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_TIP_NUM" DESCRIPTION = "Selected cantilever [1-8]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 41 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CANT_BLK_NUM" DESCRIPTION = "Selected cantilever block [1-2]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 43 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EXCITATION_LEVEL" DESCRIPTION = "Gain level of piezo-electric actuator used for cantilever excitation [0-7]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 45 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AC_GAIN_LEVEL" DESCRIPTION = "Gain level of cantilever AC signal amplifier [0-7]." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 47 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SPARE" DESCRIPTION = "Currently not used." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 49 BYTES = 14 ITEMS = 7 ITEM_BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 82 4.3.4 Data Product Design - Single Point Approach Data The MIDAS single point approach data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/SPA File naming: SPA_yydddhh_yydddhh_nnn_tt.DAT File structure: /LABEL/SPA_STRUCTURE.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A single point approach scan data record comprises 4 data channels with up to n (n=1-256) data samples each. The actual number of data samples (valid for all channels) for a record is given in the NUM_SAMPLES column. A typical PDS label for a single point approach data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 2096 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 83 PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* MISSION SPECIFIC KEYWORDS */ ROSETTA:MIDAS_TIP_NUMBER = ROSETTA:MIDAS_TARGET_NUMBER = ROSETTA:MIDAS_TARGET_TYPE = ROSETTA:MIDAS_TARGET_NAME = ROSETTA:MIDAS_LIN_STAGE_POS = ROSETTA:MIDAS_SEGMENT_NUMBER = ROSETTA:MIDAS_SCAN_START_XY = ROSETTA:MIDAS_SCAN_STOP_XY = ROSETTA:MIDAS_SCAN_DIRECTION = ROSETTA:MIDAS_SCANNING_MODE = /* DATA FILE POINTER(S) */ ^SPA_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = SPA_TABLE INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 27 ROW_BYTES = 2096 DESCRIPTION = "MIDAS scan control data" ^STRUCTURE = "SPA_STRUCTURE.FMT" END_OBJECT = SPA_TABLE END The single point approach record structure is defined as follows: /* SPA FRAME STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 84 START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINEAR_POS" DESCRIPTION = "Linear stage position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 21 BYTES = 2 OFFSET = 1.52590E-004 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 85 SCALING_FACTOR = 3.05180E-004 UNIT = VOLT END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WHEEL_POS" DESCRIPTION = "Current wheel position (segment number)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 23 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIP_NUMBER" DESCRIPTION = "Number of selected tip." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_ORIGIN" DESCRIPTION = "Scan origin in X direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 27 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_ORIGIN" DESCRIPTION = "Scan origin in Y direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STEP_SIZE" DESCRIPTION = "Line scan step size (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_STEPS" DESCRIPTION = "Number of line scan steps (pixels)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_MODE" DESCRIPTION = "Scanning mode for image acquisition): Bit 0-7: 0=DYN[amic], 1=CON[tact], 2=MAG[netic], Bit 8: line scan direction (0=std.,1=reverse), Bit 12: main scan direction (0=X,1=Y)" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 35 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAIN_SCAN_CNT" DESCRIPTION = "Current main scan counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_SAMPLES" DESCRIPTION = "Total number of measurements." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 86 START_BYTE = 39 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SPARE" DESCRIPTION = "Currently not used." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 41 BYTES = 6 ITEMS = 3 ITEM_BYTES = 2 END_OBJECT = COLUMN OBJECT = CONTAINER NAME = FRAME_STRUCTURE START_BYTE = 47 BYTES = 8 REPETITIONS = 256 DESCRIPTION = "Container for the 256 repeating DAQ samples of AC, DC, phase and Z position signal." OBJECT = COLUMN NAME = "AC_SAMPLE" DESCRIPTION = "Cantilever AC signal sample." DATA_TYPE = MSB_INTEGER START_BYTE = 1 BYTES = 2 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 UNIT = VOLT FORMAT = "F6.2" DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DC_SAMPLE" DESCRIPTION = "Cantilever DC signal samples." DATA_TYPE = MSB_INTEGER START_BYTE = 3 BYTES = 2 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 UNIT = VOLT FORMAT = "F6.2" DERIVED_MINIMUM = -10.0 DERIVED_MAXIMUM = +10.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PHASE_SAMPLE" DESCRIPTION = "Cantilever phase signal samples." DATA_TYPE = MSB_INTEGER START_BYTE = 5 BYTES = 2 SCALING_FACTOR = 5.4932E-03 OFFSET = 0.0 UNIT = DEGREE FORMAT = "F6.1" DERIVED_MINIMUM = -180.0 DERIVED_MAXIMUM = +180.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_POS_SAMPLE" DESCRIPTION = "Z piezo position monitor (strain gauge)." DATA_TYPE = MSB_INTEGER START_BYTE = 7 BYTES = 2 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 UNIT = VOLT FORMAT = "F6.2" DERIVED_MINIMUM = -10.0 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 87 DERIVED_MAXIMUM = +10.0 END_OBJECT = COLUMN END_OBJECT = CONTAINER OBJECT = COLUMN NAME = "CRC16_CHECKSUM" DESCRIPTION = "Telemetry packet checksum (CRC 16)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 2095 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 88 4.3.5 Data Product Design - Single Point Sampling Data The MIDAS single point sampling data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/SPS File naming: SPS_yydddhh_yydddhh_nnn_tt.DAT File structure: /LABEL/SPS_PREFIX.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A single point sampling scan comprises n (n=1-65535) scan cycles with 4 data channels of 256 samples each. This data can be mapped to a time series table consisting of n rows and 4 interleaved columns with 256 items. Thus the sampling parameter interval of the table object is 256 times the sampling parameter interval of the associated column object. The time range for a given scan is defined by the following keywords of the TIME_SERIES object: Scan cycles: ROWS (total number of samples per channel = 256*ROWS) Time step: SAMPLING_PARAMETER_INTERVAL/256 Time range: (256*ROWS - 1)*SAMPLING_PARAMETER_INTERVAL/256 A typical PDS label for a single point sampling data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 2096 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 89 START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* MISSION SPECIFIC KEYWORDS */ ROSETTA:MIDAS_TIP_NUMBER = ROSETTA:MIDAS_TARGET_NUMBER = ROSETTA:MIDAS_TARGET_TYPE = ROSETTA:MIDAS_TARGET_NAME = ROSETTA:MIDAS_LIN_STAGE_POS = ROSETTA:MIDAS_SEGMENT_NUMBER = ROSETTA:MIDAS_SCAN_START_XY = ROSETTA:MIDAS_SCAN_STOP_XY = ROSETTA:MIDAS_SCAN_DIRECTION = ROSETTA:MIDAS_SCANNING_MODE = /* DATA FILE POINTER(S) */ ^ROW_PREFIX_TABLE = "" ^TIME_SERIES = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = ROW_PREFIX_TABLE NAME = PKT_HEADER INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 22 ROW_BYTES = 46 ROW_SUFFIX_BYTES = 2050 DESCRIPTION = "Control data prefix table" ^STRUCTURE = "SPS_PREFIX.FMT" END_OBJECT = ROW_PREFIX_TABLE OBJECT = TIME_SERIES NAME = CONTROL_DATA INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 4 ROW_PREFIX_BYTES = 46 ROW_BYTES = 2048 ROW_SUFFIX_BYTES = 2 SAMPLING_PARAMETER_NAME = TIME SAMPLING_PARAMETER_UNIT = SECONDS SAMPLING_PARAMETER_INTERVAL = 3.6900E-1 DESCRIPTION = "MIDAS hi-res sampling data" OBJECT = COLUMN NAME = AC_SAMPLES DATA_TYPE = MSB_INTEGER START_BYTE = 1 BYTES = 2042 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 90 ITEMS = 256 ITEM_BYTES = 2 ITEM_OFFSET = 8 SAMPLING_PARAMETER_NAME = TIME SAMPLING_PARAMETER_UNIT = SECONDS SAMPLING_PARAMETER_INTERVAL = 1.4414E-3 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = DC_SAMPLES DATA_TYPE = MSB_INTEGER START_BYTE = 3 BYTES = 2042 ITEMS = 256 ITEM_BYTES = 2 ITEM_OFFSET = 8 SAMPLING_PARAMETER_NAME = TIME SAMPLING_PARAMETER_UNIT = SECONDS SAMPLING_PARAMETER_INTERVAL = 1.4414E-3 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = PHASE_SAMPLES DATA_TYPE = MSB_INTEGER START_BYTE = 5 BYTES = 2042 ITEMS = 256 ITEM_BYTES = 2 ITEM_OFFSET = 8 SAMPLING_PARAMETER_NAME = TIME SAMPLING_PARAMETER_UNIT = SECONDS SAMPLING_PARAMETER_INTERVAL = 1.4414E-3 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = Z_POS_SAMPLES DATA_TYPE = MSB_INTEGER START_BYTE = 7 BYTES = 2042 ITEMS = 256 ITEM_BYTES = 2 ITEM_OFFSET = 8 SAMPLING_PARAMETER_NAME = TIME SAMPLING_PARAMETER_UNIT = SECONDS SAMPLING_PARAMETER_INTERVAL = 1.4414E-3 SCALING_FACTOR = 3.0518E-04 OFFSET = 0.0 DERIVED_MINIMUM = 0.0 DERIVED_MAXIMUM = 10.0 END_OBJECT = COLUMN END_OBJECT = TIME_SERIES END The single point sampling prefix structure is defined as follows: /* SPS PREFIX STRUCTURE */ OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 91 NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 92 START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINEAR_POS" DESCRIPTION = "Linear stage position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 21 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = VOLT END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WHEEL_POS" DESCRIPTION = "Current wheel position (segment number)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 23 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIP_NUMBER" DESCRIPTION = "Number of selected tip." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_ORIGIN" DESCRIPTION = "Scan origin in X direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 27 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_ORIGIN" DESCRIPTION = "Scan origin in Y direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STEP_SIZE" DESCRIPTION = "Line scan step size (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_STEPS" DESCRIPTION = "Number of line scan steps (pixels)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_MODE" DESCRIPTION = "Scanning mode for image acquisition): Bit 0-7: 0=DYN[amic], 1=CON[tact], 2=MAG[netic], Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 93 Bit 8: line scan direction (0=std.,1=reverse), Bit 12: main scan direction (0=X,1=Y)" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 35 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAIN_SCAN_CNT" DESCRIPTION = "Current main scan counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_SAMPLES" DESCRIPTION = "Total number of measurements." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 39 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SPARE" DESCRIPTION = "Currently not used." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 41 BYTES = 6 ITEMS = 3 ITEM_BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 94 4.3.6 Data Product Design - Line Scan Data The MIDAS line scan data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/LIN File naming: LIN_yydddhh_yydddhh_nnn_tt.DAT File structure: /LABEL/LIN_STRUCTURE.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A line scan can have n (n=32, 64, .., 512) data points depending on the commanded number of pixels in the main scan direction. The line scan records have a fixed size, capable of holding the maximum number of 512 line scan data points. The actual number of data points for a given record can be determined from the NUM_STEPS column. Note: The column TIP_NUMBER is always 0 for telemetry data generated prior to payload checkout #4 (corrected via S/W upload). Nevertheless, the proper value can be obtained from the mission specific keyword MIDAS_TIP_NUMBER which is included in the PDS label. A typical PDS label for a line scan data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 1072 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 95 SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* MISSION SPECIFIC KEYWORDS */ ROSETTA:MIDAS_TIP_NUMBER = ROSETTA:MIDAS_TARGET_NUMBER = ROSETTA:MIDAS_TARGET_TYPE = ROSETTA:MIDAS_TARGET_NAME = ROSETTA:MIDAS_LIN_STAGE_POS = ROSETTA:MIDAS_SEGMENT_NUMBER = ROSETTA:MIDAS_SCAN_START_XY = ROSETTA:MIDAS_SCAN_STOP_XY = ROSETTA:MIDAS_SCAN_DIRECTION = ROSETTA:MIDAS_SCANNING_MODE = /* DATA FILE POINTER(S) */ ^LINE_SCAN_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = LINE_SCAN_TABLE INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 23 ROW_BYTES = 1072 DESCRIPTION = "MIDAS line scan data" ^STRUCTURE = "LIN_STRUCTURE.FMT" END_OBJECT = LINE_SCAN_TABLE END The line scan data structure is defined as follows: /* LINE SCAN FRAME STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 96 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 97 NAME = "LINEAR_POS" DESCRIPTION = "Linear stage position sensor readout." DATA_TYPE = MSB_INTEGER START_BYTE = 21 BYTES = 2 OFFSET = 1.52590E-004 SCALING_FACTOR = 3.05180E-004 UNIT = VOLT END_OBJECT = COLUMN OBJECT = COLUMN NAME = "WHEEL_POS" DESCRIPTION = "Current wheel position (segment number)." DATA_TYPE = MSB_INTEGER START_BYTE = 23 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIP_NUMBER" DESCRIPTION = "Number of selected tip." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_ORIGIN" DESCRIPTION = "Scan origin in X direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 27 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Y_ORIGIN" DESCRIPTION = "Scan origin in Y direction (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STEP_SIZE" DESCRIPTION = "Line scan step size (DAC units)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_STEPS" DESCRIPTION = "Number of line scan steps (pixels)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCAN_MODE" DESCRIPTION = "Scanning mode for image acquisition): Bit 0-7: 0=DYN[amic], 1=CON[tact], 2=MAG[netic], Bit 8: line scan direction (0=std.,1=reverse), Bit 12: main scan direction (0=X,1=Y)" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 35 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LINE_SCAN_CNT" DESCRIPTION = "Current line scan counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 98 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SPARE" DESCRIPTION = "Currently not used." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 39 BYTES = 8 ITEMS = 4 ITEM_BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "Z_SET_VALUE" DESCRIPTION = "Line scan data vector (Z piezo DAC set value)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 47 BYTES = 1024 ITEMS = 512 ITEM_BYTES = 2 SCALING_FACTOR = 1.6400E-001 OFFSET = 0.0000E+000 UNIT = "nm" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CRC16_CHECKSUM" DESCRIPTION = "Telemetry packet checksum (CRC 16)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1071 BYTES = 2 END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 99 4.3.7 Data Product Design - Image Scan Data The MIDAS image data files are stored in BCR format which is described in chapter 3.2.4. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL: Data directory: /DATA/IMG File naming: IMG_yydddhh_yydddhh_nnn_dd.IMG A typical PDS label for an image data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 2048 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 100 /* PIXEL SCALING (HORIZONTAL=X, VERTICAL=Y) */ HORIZONTAL_PIXEL_SCALE = VERTICAL_PIXEL_SCALE = /* MISSION SPECIFIC KEYWORDS */ ROSETTA:MIDAS_TIP_NUMBER = ROSETTA:MIDAS_TARGET_NUMBER = ROSETTA:MIDAS_TARGET_TYPE = ROSETTA:MIDAS_TARGET_NAME = ROSETTA:MIDAS_LIN_STAGE_POS = ROSETTA:MIDAS_SEGMENT_NUMBER = ROSETTA:MIDAS_SCAN_START_XY = ROSETTA:MIDAS_SCAN_STOP_XY = ROSETTA:MIDAS_SCAN_DIRECTION = ROSETTA:MIDAS_SCANNING_MODE = ROSETTA:MIDAS_SCAN_DATA_TYPE = /* DATA FILE POINTER(S) */ ^BCR_HEADER = "" ^BCR_IMAGE = ("",2) OBJECT = BCR_HEADER BYTES = 2048 HEADER_TYPE = TEXT INTERCHANGE_FORMAT = BINARY RECORDS = 1 DESCRIPTION = " BCR-STM format as used by the Image Metrology SPIP application. Parameter definitions are given in file /DOCUMENT/MID_EIDC.pdf" END_OBJECT = BCR_HEADER OBJECT = BCR_IMAGE LINES = LINE_SAMPLES = SAMPLE_BITS = 16 SAMPLE_TYPE = LSB_UNSIGNED_INTEGER DESCRIPTION = "" SCALING_FACTOR = OFFSET = END_OBJECT = BCR_IMAGE END Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 101 4.3.8 Data Product Design - Feature Vector Data The MIDAS feature vector data files are binary tables containing the plain telemetry packets as retrieved from the DDS. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/ROI File naming: ROI_yydddhh_yydddhh_nnn_ff.DAT File structure: /LABEL/ROI_STRUCTURE.FMT Parameters having a physical representation can be calibrated by applying the OFFSET, SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file) to the raw value: physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT] A feature vector record comprises 64 feature vector frames having identical vector parameters. The actual number of feature vectors for a record is given in the NUM_VECTORS column. The repeating structure of the 64 feature vectors is defined by means of the PDS CONTAINER object. A typical PDS label for a feature vector data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 2096 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 102 PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* DATA FILE POINTER(S) */ ^ROI_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = ROI_TABLE INTERCHANGE_FORMAT = BINARY ROWS = COLUMNS = 35 ROW_BYTES = 2096 DESCRIPTION = "MIDAS feature vector data" ^STRUCTURE = "ROI_STRUCTURE.FMT" END_OBJECT = ROI_TABLE END The feature vector structure is defined as follows: /* MIDAS FEATURE VECTOR FRAME STRUCTURE */ OBJECT = COLUMN NAME = "PACKET_ID" DESCRIPTION = "Telemetry packet identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SEQUENCE_CONTROL" DESCRIPTION = "Telemetry packet sequence counter." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_LENGTH" DESCRIPTION = "Telemetry packet length." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_SECONDS" DESCRIPTION = "S/C clock count at packet generation." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_OBT_FRACTION" DESCRIPTION = "Fractional part of S/C clock count." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 103 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 11 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PUS_AND_CRC" DESCRIPTION = "Telemetry packet PUS-Version and CRC flag." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_TYPE" DESCRIPTION = "Telemetry packet type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 14 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_SUBTYPE" DESCRIPTION = "Telemetry packet sub-type." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 15 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PACKET_PAD_FIELD" DESCRIPTION = "Telemetry packet padding field." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 16 BYTES = 1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STRUCTURE_ID" DESCRIPTION = "Telemetry packet structure identifier." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOFTWARE_VERSION" DESCRIPTION = "On-board software version." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DATASET_ID" DESCRIPTION = "Identifier of analysed data set." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 21 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TOT_VECTORS" DESCRIPTION = "Total number of detected features." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 23 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VECTOR_IDX" DESCRIPTION = "Index of first feature vector (x2)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 2 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 104 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NUM_VECTORS" DESCRIPTION = "Number of feature vectors in packet." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 27 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MIN_Z_VALUE" DESCRIPTION = "Minimum Z value of image." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MAX_Z_VALUE" DESCRIPTION = "Maximum Z value of image." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 31 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SELECTED_IDX" DESCRIPTION = "Index of favoured feature vector." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 33 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SELECTED_WEIGHT" DESCRIPTION = "Weighting of favoured feature vector." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 35 BYTES = 2 SCALING_FACTOR = 6.1036E-5 OFFSET = 0.0 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_REG_OFFS" DESCRIPTION = "Linear regression offset value." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 37 BYTES = 2 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_REG_XFACT" DESCRIPTION = "Linear regression X factor (x65535)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 39 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIN_REG_YFACT" DESCRIPTION = "Linear regression Y factor (x65535)." DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 43 BYTES = 4 END_OBJECT = COLUMN OBJECT = CONTAINER NAME = "VECTOR_STRUCTURE" START_BYTE = 47 BYTES = 32 REPETITIONS = 64 DESCRIPTION = "Represents the format of the 64 repeating feature vector attributes." Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 105 OBJECT = COLUMN NAME = "NUM_POINTS" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 2 DESCRIPTION = "Number of feature vector data points." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "X_IDX_MAX" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 1 DESCRIPTION = "Maximum X position index." END_OBJECT = COLUMN OBJECT = COLUMN NAME = X_IDX_MIN DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 4 BYTES = 1 DESCRIPTION = "Minimum X position index." END_OBJECT = COLUMN OBJECT = COLUMN NAME = Y_IDX_MAX DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 1 DESCRIPTION = "Maximum y position index." END_OBJECT = COLUMN OBJECT = COLUMN NAME = Y_IDX_MIN DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 6 BYTES = 1 DESCRIPTION = "Minimum Y position index." END_OBJECT = COLUMN OBJECT = COLUMN NAME = Z_MAX_LVL DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 2 DESCRIPTION = "Maximum Z value over threshold level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = X_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 9 BYTES = 4 DESCRIPTION = "Sum of X position indices." END_OBJECT = COLUMN OBJECT = COLUMN NAME = Y_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 13 BYTES = 4 DESCRIPTION = "Sum of Y position indices." END_OBJECT = COLUMN OBJECT = COLUMN NAME = Z_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 4 DESCRIPTION = "Sum of Z position indices." END_OBJECT = COLUMN OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 106 NAME = XX_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 21 BYTES = 4 DESCRIPTION = "Sum of X*X position indices." END_OBJECT = COLUMN OBJECT = COLUMN NAME = YY_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 4 DESCRIPTION = "Sum of Y*Y position indices." END_OBJECT = COLUMN OBJECT = COLUMN NAME = XY_IDX_SUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 4 DESCRIPTION = "Sum of X*Y position indices." END_OBJECT = COLUMN END_OBJECT = CONTAINER OBJECT = COLUMN NAME = CRC16_CHECKSUM DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 2095 BYTES = 2 DESCRIPTION = "Telemetry packet checksum (CRC 16)." END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 107 4.3.9 Data Product Design - Event Data The MIDAS event data files are ASCII tables containing the list of events within a given time period. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA/EVN File naming: EVN_yydddhh_yydddhh.TAB File structure: /LABEL/EVN_STRUCTURE.FMT A typical PDS label for an event data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 80 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* GEOMETRY INFORMATION */ SC_SUN_POSITION_VECTOR = SC_TARGET_POSITION_VECTOR = SC_TARGET_VELOCITY_VECTOR = SPACECRAFT_ALTITUDE = Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 108 SUB_SPACECRAFT_LATITUDE = SUB_SPACECRAFT_LONGITUDE = /* DATA FILE POINTER(S) */ ^EVENT_TABLE = "" /* DATA OBJECT DEFINITION(S) */ OBJECT = EVENT_TABLE INTERCHANGE_FORMAT = ASCII ROWS = COLUMNS = 5 ROW_BYTES = 80 DESCRIPTION = "MIDAS event data" ^STRUCTURE = "EVN_STRUCTURE.FMT" END_OBJECT = EVENT_TABLE END The event data file structure is defined as follows: /* EVENT DATA STRUCTURE */ OBJECT = COLUMN NAME = EVENT_OBT DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 14 UNIT = SECOND DESCRIPTION = "S/C clock count at event generation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_UTC DATA_TYPE = DATE START_BYTE = 16 BYTES = 23 DESCRIPTION = "Event generation time in UTC format." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_CNT DATA_TYPE = ASCII_INTEGER START_BYTE = 40 BYTES = 5 DESCRIPTION = "On-board event counter." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_SID DATA_TYPE = ASCII_INTEGER START_BYTE = 46 BYTES = 5 DESCRIPTION = "Event identifier." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_NAME DATA_TYPE = CHARACTER START_BYTE = 53 BYTES = 25 DESCRIPTION = "Event description." END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 109 4.3.10 Data Product Design - Cantilever Utilisation History Data The MIDAS cantilever history data files are ASCII tables containing the list of events for a certain cantilever within a given time period. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA File naming: CAH_yydddhh_yydddhh_tt.TAB File structure: /LABEL/CAH_STRUCTURE.FMT A typical PDS label for a cantilever history data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 119 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* DATA FILE POINTER(S) */ ^EVENT_TABLE = "" /* DATA OBJECT DEFINITION(S) */ Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 110 OBJECT = EVENT_TABLE NAME = CANTILEVER_HISTORY INTERCHANGE_FORMAT = ASCII ROWS = COLUMNS = 11 ROW_BYTES = 119 DESCRIPTION = "MIDAS cantilever history data" ^STRUCTURE = "CAH_STRUCTURE.FMT" END_OBJECT = EVENT_TABLE END The cantilever history data structure is defined as follows: /* CANTILEVER HISTORY DATA STRUCTURE */ OBJECT = COLUMN NAME = START_OBT DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 15 UNIT = SECOND DESCRIPTION = "S/C clock count at event start." END_OBJECT = COLUMN OBJECT = COLUMN NAME = START_UTC DATA_TYPE = DATE START_BYTE = 17 BYTES = 23 DESCRIPTION = "Event start time in UTC format." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STOP_OBT DATA_TYPE = ASCII_REAL START_BYTE = 41 BYTES = 15 UNIT = SECOND DESCRIPTION = "S/C clock count at event stop." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STOP_UTC DATA_TYPE = DATE START_BYTE = 57 BYTES = 23 DESCRIPTION = "Event stop time in UTC format." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT DATA_TYPE = CHARACTER START_BYTE = 82 BYTES = 8 DESCRIPTION = "Textual description of the event." END_OBJECT = COLUMN OBJECT = COLUMN NAME = AC_GAIN DATA_TYPE = ASCII_INTEGER START_BYTE = 93 BYTES = 1 DESCRIPTION = "Gain level of cantilever AC signal amplifier [0-7]." END_OBJECT = COLUMN OBJECT = COLUMN NAME = DC_GAIN DATA_TYPE = ASCII_INTEGER START_BYTE = 95 Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 111 BYTES = 1 DESCRIPTION = "Gain level of cantilever DC signal amplifier [0-7]." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EXC_LVL DATA_TYPE = ASCII_INTEGER START_BYTE = 97 BYTES = 1 DESCRIPTION = "Gain level of piezo-electric actuator used for cantilever excitation [0-7]." END_OBJECT = COLUMN OBJECT = COLUMN NAME = U_MAX DATA_TYPE = ASCII_REAL UNIT = VOLT START_BYTE = 99 BYTES = 5 DESCRIPTION = "Max. cantilever signal amplitude detected during frequency scan." END_OBJECT = COLUMN OBJECT = COLUMN NAME = F_MAX DATA_TYPE = ASCII_REAL UNIT = HERTZ START_BYTE = 105 BYTES = 8 DESCRIPTION = "Frequency where the maximum signal amplitude was detected." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SCAN_MODE DATA_TYPE = CHARACTER START_BYTE = 115 BYTES = 3 DESCRIPTION = "Scanning mode for image acquisition e.g. DYN[amic], CON[tact] or MAG[netic]." END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 112 4.3.11 Data Product Design - Target Utilisation History Data The MIDAS target history data files are ASCII tables containing the list of events for a certain target within a given time period. Each data file has associated a detached PDS label with the same name as the data file it describes, but with the extension .LBL. The data file columns are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels: Data directory: /DATA File naming: TGH_yydddhh_yydddhh_tt.TAB File structure: /LABEL/TGH_STRUCTURE.FMT A typical PDS label for a target history data file is given below: PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "" RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 95 FILE_RECORDS = DATA_SET_ID = "" DATA_SET_NAME = "" PRODUCT_ID = "" PRODUCT_VERSION_ID = "" PRODUCT_CREATION_TIME = PRODUCT_TYPE = PROCESSING_LEVEL_ID = MISSION_ID = ROSETTA MISSION_NAME = "INTERNATIONAL ROSETTA MISSION" MISSION_PHASE_NAME = "" INSTRUMENT_HOST_ID = INSTRUMENT_HOST_NAME = "" INSTRUMENT_ID = INSTRUMENT_NAME = "" INSTRUMENT_TYPE = "" INSTRUMENT_MODE_ID = INSTRUMENT_MODE_DESC = "" TARGET_NAME = "" TARGET_TYPE = "" START_TIME = STOP_TIME = SPACECRAFT_CLOCK_START_COUNT = "" SPACECRAFT_CLOCK_STOP_COUNT = "" NATIVE_START_TIME = NATIVE_STOP_TIME = PRODUCER_ID = "" PRODUCER_FULL_NAME = "" PRODUCER_INSTITUTION_NAME = "" DATA_QUALITY_ID = DATA_QUALITY_DESC = "" /* DATA FILE POINTER(S) */ ^EVENT_TABLE = "" /* DATA OBJECT DEFINITION(S) */ Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 113 OBJECT = EVENT_TABLE NAME = TARGET_HISTORY INTERCHANGE_FORMAT = ASCII ROWS = COLUMNS = 6 ROW_BYTES = 95 DESCRIPTION = "MIDAS target history data" ^STRUCTURE = "TGH_STRUCTURE.FMT" END_OBJECT = EVENT_TABLE END The target history data structure is defined as follows: /* TARGET HISTORY DATA STRUCTURE */ OBJECT = COLUMN NAME = START_OBT DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 15 UNIT = SECOND DESCRIPTION = "S/C clock count at event start." END_OBJECT = COLUMN OBJECT = COLUMN NAME = START_UTC DATA_TYPE = DATE START_BYTE = 17 BYTES = 23 DESCRIPTION = "Event start time in UTC format." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STOP_OBT DATA_TYPE = ASCII_REAL START_BYTE = 41 BYTES = 15 UNIT = SECOND DESCRIPTION = "S/C clock count at event stop." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STOP_UTC DATA_TYPE = DATE START_BYTE = 57 BYTES = 23 DESCRIPTION = "Event stop time in UTC format." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT DATA_TYPE = CHARACTER START_BYTE = 82 BYTES = 8 DESCRIPTION = "Textual description of the event." END_OBJECT = COLUMN OBJECT = COLUMN NAME = FLUX_OR_TIP DATA_TYPE = ASCII_INTEGER START_BYTE = 92 BYTES = 2 DESCRIPTION = "Maximum dust flux or tip number." END_OBJECT = COLUMN Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 114 5 Appendix: Available Software to read PDS files The MIDAS archive data sets can be displayed and validated with the MIDAS Data Set Browser software. The contents of a MIDAS archive data set can be browsed by means of a tree-like structure, displaying the data set directory hierarchy (nodes) an the associated data files (leafs). The software is entirely written in IDL and the source code is included in the data sets. Figure 5.1 shows a frequency scan from the RO-X-MIDAS-3-MARS-PC3-5 data set: The browser window is structured into two panels holding the following components (from top to bottom): Left Panel: - Data set hierarchy window - used for navigation - Data file attribute window - shows data file attributes (e.g. row prefix values) - Plot parameter selection window - plot parameter selection Right Panel: - Data file path windows - displays the full path of the selected PDS file - Text window - displays text files or PDS data file labels - Graphic/Table window - used for data plotting or tabular data display Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 115 5.1 Program Description 5.1.1 Program Installation Before starting the program, the source files need to be copied to a directory on a machine having IDL (6.4 or higher) installed. The source files (extension *.PRO) are located in the DOCUMENT directory of a data set. In order to make IDL aware of the new modules, the directory holding the source files should be added to the IDL path preferences (File- >Preferences->Path). 5.1.2 Starting the Program After starting up IDL, the MIDAS Data Set Browser can be started with the following command: IDL> mid_browse [,_data_set_root] The parameter data_set_root is optional. It can be used to define the root directory of the MIDAS data set (usually the directory holding the AAREADME.TXT and VOLDESC.CAT files) at start- up. If this parameter is not present, the S/W displays a file selection dialog from where the root directory can be selected. 5.1.3 Navigating the Data Set The upper left window shows a tree-like structure displaying the data set hierarchy (directories and files). Directories can be expanded/collapsed by clicking on the `+'/'-` symbol in front of the directory icon. Double-clicking on the directory icon or the directory name toggles between expanded and collapsed mode. The up and down arrow keys can be used to navigate sequentially through the directories and files. Data set files are usually displayed with the file extension included. Nevertheless, in order to reduce the amount of displayed files, the file extension is stripped of from files located in the DATA directory and all subjacent directories. This results in a common filename (without extension) for the data files and the respective PDS labels. 5.1.4 Data Display Information from a data set file can be retrieved by selecting the file in the data set hierarchy window (entry is highlighted). Text files: Data set files having the extension .CAT, .FMT, .LBL, .TAB and .TXT are displayed in the upper right text display window. No data validation is applied to these files. Adobe PDF files: When selecting a Portable Data Format file, the file is displayed in the application associated to the .PDF file extension on the system (if any). Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 116 PNG Images: Images stored in PNG format are displayed in the graphic panel located in the lower right corner of the main window. Files in the DATA directory: Files located in and underneath the DATA directory are treated differently than the data set files already mentioned. PDS labels are validated and ^STRUCTURE statements are expanded. The resulting PDS labels are displayed in the text window. Comments are removed from the PDS labels. The associated data files are loaded and the information is displayed in several windows, depending on the data product type: EVN, CAH and TGH Data: The table contents are displayed in the table data panel located in the lower left corner of the main window. FSC Data: The resonance curve of one scan cycle of the frequency sweep is displayed in the graphic panel. The red square indicates the resonance peak which has been found by the on-board S/W within the current scan cycle. General frequency scan cycle attributes (row prefix) are displayed in the data file attribute panel. If more than one frequency sweep record is stored in the selected data file, the plot parameter drop-list can be used to navigate through the records. HK1, HK2 Data: Housekeeping data parameters are plotted in the graphic panel. The parameters can be selected from the plot parameter drop-list. Due to the rather poor performance of the 3rd party S/W for reading and validating the PDS labels, loading of the extended housekeeping data (HK2) might take some time. IMG Data: Images are displayed in the graphic panel. LIN Data: Line scans are displayed in the graphic panel. General line scan attributes (row prefix) are displayed in the data file attribute panel. If more than one line scan record is stored in the selected data file, the plot parameter drop-list can be used to navigate through the records. SPA, SPS Data: Single point scans are displayed in the graphic panel. General single point scan attributes (row prefix) are displayed in the data file attribute panel. If more than one single point scan record is stored in the selected data file, the plot parameter drop-list can be used to navigate through the records. 5.2 Program Source Files 5.2.1 MIDAS Data Set Browser The MIDAS Data Set Browser comprises the following IDL source modules: error_msg - utility for printing error messages escape.pro - utility for handling escape sequences in strings ini_file.pro - utility for saving and restoring program settings mid_browse.pro - the MIDAS Data Set Browser main program release.pro - MIDAS Data Set Browser software revision tostr.pro - extended string conversion (e.g. date values) Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 117 5.2.2 Small Bodies Node (SBN) PDS Library The READPDS library was created at the Small Bodies Node (SBN) of the Planetary Data System (PDS) to read PDS image and data files. The release provided in the archive is version 4.9 dating from 2016-03-02. The library consists of the following modules: addeobj.pro - insert END_OBJECT keyword if not present and pad lines to 80 bytes apply_bitmask.pro - applies bitmask on integer arrays or scalars arr_struct.pro - populates an IDL structure for array object to be read arrcol_struct.pro - construct an IDL structure for a given array or collection arrcolascpds.pro - read a PDS ASCII array or collection object into an IDL structure arrcolpds.pro - read a PDS binary array or collection object into an IDL structure btabvect2.pro - convert NxM dimensional column vector into IDL data type clean.pro - remove all unprintable characters from a string cleanarr.pro - remove all unprintable characters from a string array coll_struct.pro - populates an IDL structure for collection object to be read elem_struct.pro - populates an IDL structure for element object to be read get_index.pro - retrieves viable END_OBJECT index position in a PDS label headpds.pro - read a PDS label into an array variable histogram.pro - read and display PDs histogram objects imagepds.pro - read an image array into an array variable objpds.pro - obtain viable data objects from a PDS label pdspar.pro - obtain the value of a parameter in a PDS header pointpds.pro - retrieves pointer information for PDS object from label qubepds.pro - read a 3D image qube object into a 3D IDL array readhistory.pro - read a history object into a string array variable readpds.pro - reads a PDS file into IDL data and label variables readspreadsheet.pro - read a PDS spreadsheet object into an IDL structure remove_chars.pro - remove all specified characters from a string str2num.pro - returns numeric value of a string tascpds.pro - read a PDS ASCII table into an IDL structure tbinpds.pro - read a PDS binary table file into an IDL structure timepds.pro - extract time from PDS label or ASCII table Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 118 6 Appendix: Example of Directory Listing of Data Set X [TOP-LEVEL-DIRECTORY] | |-- .PDSVOLUME.XML Archive data file catalog generated by PVV. |-- AAREADME.TXT Overview description of the data set contents. |-- VOLDESC.CAT Description of the contents of this volume. | |--[CALIB] Directory containing PDS calibration objects. | | | |-- CALINFO.TXT Description of files in the CALIB directory. | |-- MIDCALIB.LBL PDS label describing the MIDAS calibration table. | +-- MIDCALIB.TAB Standard MIDAS calibration table in ASCII format. | |--[CATALOG] Directory containing PDS catalog objects. | | | |-- CATINFO.TXT Description of files in the CATALOG directory. | |-- DATASET.CAT Description of the MIDAS data set. | |-- INST.CAT Description of the MIDAS instrument. | |-- INSTHOST.CAT Description of the ROSETTA spacecraft. | |-- MISSION.CAT Description of the ROSETTA mission. | |-- REFERENCE.CAT List of publications mentioned in catalog files. | |-- SOFTWARE.CAT Description of provided S/W to read the data set. | +-- TARGET.CAT Description of the ROSETTA mission targets. | |--[DATA] Directory containing the MIDAS data files. | | | |--[EVN] Directory containing MIDAS event data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS event data files in ASCII format. | | | |--[FSC] Directory containing MIDAS frequency scan data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS frequency scan data files in binary format. | | | |--[HK1] Directory containing MIDAS standard HK data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS standard HK data files in binary format. | | | |--[HK2] Directory containing MIDAS extended HK data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS extended HK data files in binary format. | | | |--[IMG] Directory containing MIDAS image data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.BCR MIDAS image data files in STM-BCR format. | | | |--[LIN] Directory containing MIDAS line scan data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS line scan data files in binary format. | | | |--[ROI] Directory containing MIDAS feature vector data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS feature vector data files in binary format. | | | |--[SPA] Directory containing MIDAS DAQ approach data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS DAQ approach data files in binary format. | | | |--[SPS] Directory containing MIDAS DAQ sampling data. | | | | | |-- *.LBL Detached label files describing the data. | | +-- *.TAB MIDAS DAQ sampling data files in binary format. Document No. : MID-IWF-TN-0087 ROSETTA-MIDAS to PSA Issue/Rev. No. : 2.0 Interface Control Document Date : 16 November 2017 Page : 119 | | | |-- CAH*.TAB MIDAS cantilever history files in ASCII format. | |-- TGH*.TAB MIDAS target history files in ASCII format. | +-- *.LBL Detached label files describing the data. | |--[DOCUMENT] Directory containing volume related documents. | | | |--[CODE] Directory containing data browser S/W modules. | | | | | |-- MID_BROWSE.LBL PDS label describing the software modules. | | |-- MID_BROWSE.PRO MIDAS data browser main program (IDL). | | +-- *.PRO MIDAS data browser S/W source modules (IDL). | | | |-- DOCINFO.TXT Description of files in the DOCUMENT directory. | |-- MID_*.LBL PDS labels for documents. | |-- MID_EICD.TXT MIDAS to PSA interface document in ASCII format. | |-- MID_EICD.PDF MIDAS to PSA interface document in PDF format. | |-- MID_EICD_*.PNG MIDAS to PSA I/F document images in PDS format. | |-- MID_SSRV.TXT MIDAS instrument paper in ASCII format. | |-- MID_SSRV.PDF MIDAS instrument paper in Adobe PDF format. | |-- MID_SSRV_*.PNG MIDAS instrument paper images in PNG format. | |-- MID_USER.TXT MIDAS user manual in ASCII format. | |-- MID_USER.PDF MIDAS user manual in Adobe PDF format. | +-- MID_USER_*.PNG MIDAS user manual images in PNG format. | +--[INDEX] Directory containing index files. | |-- INDXINFO.TXT Description of files in the INDEX directory. |-- INDEX.TAB Index table of MIDAS data in this data set. +-- INDEX.LBL PDS label for INDEX.TAB file.