/* Contents of format file "IMA_SPECTRUM_HKMU.FMT" */ OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 UNIT = "N/A" DESCRIPTION = "This column represents the UTC of the IMA HK data set in PDS standard format YYYY-MM-DDThh:mm:ss.sss" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "OBT" DATA_TYPE = CHARACTER START_BYTE = 26 BYTES = 19 UNIT = "N/A" DESCRIPTION = "On board Time (OBT) is represented as : /. with : integer starting at 1 Reset number 1 starts at 2005-03-01T00:00:00 UTC : 10 digits number of unit seconds : 5 digits number of fractional seconds expressed as multiples of 2^-16 seconds" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "SW_VERSION" DATA_TYPE = ASCII_INTEGER START_BYTE = 47 BYTES = 5 UNIT = "N/A" FORMAT = "I5" DESCRIPTION = "Software version To decode into Binary format. Bit description: patchVersion [3:0] minorVersion [8:4] majorVersion [13:9] releaseClass [15:14]: 1 (D), 2 (T), 3 (R)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "HK_I_PLUS_30V" DATA_TYPE = ASCII_REAL START_BYTE = 53 BYTES = 6 UNIT = "MILLIAMPERE" FORMAT = "F6.2" DESCRIPTION = "HK i +30V in milli-amperes" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "HK_I_PLUS_5V" DATA_TYPE = ASCII_REAL START_BYTE = 60 BYTES = 7 UNIT = "MILLIAMPERE" FORMAT = "F7.2" DESCRIPTION = "HK i +5V in milli-amperes" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "HK_V_PLUS_12V" DATA_TYPE = ASCII_REAL START_BYTE = 68 BYTES = 5 UNIT = "VOLT" FORMAT = "F5.2" DESCRIPTION = "HK V +12V in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "HK_V_PLUS_30V" DATA_TYPE = ASCII_REAL START_BYTE = 74 BYTES = 6 UNIT = "VOLTS" FORMAT = "F6.2" DESCRIPTION = "HK V +30V in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "HK_V_PLUS_5V" DATA_TYPE = ASCII_REAL START_BYTE = 81 BYTES = 4 UNIT = "VOLT" FORMAT = "F4.2" DESCRIPTION = "HK V +5V in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "HK_V_MINUS_12V" DATA_TYPE = ASCII_REAL START_BYTE = 86 BYTES = 6 UNIT = "VOLT" FORMAT = "F6.2" DESCRIPTION = "HK V -12V in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = "HK_V_MINUS_5V" DATA_TYPE = ASCII_REAL START_BYTE = 93 BYTES = 5 UNIT = "VOLT" FORMAT = "F5.2" DESCRIPTION = "HK V -5V in Volts" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = "SUN_SENSOR_1" DATA_TYPE = ASCII_INTEGER START_BYTE = 99 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Sun sensor 1 output" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "SUN_SENSOR_2" DATA_TYPE = ASCII_INTEGER START_BYTE = 101 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "Sun sensor 2 output" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "IMA_PLUS_MINUS_5V_ON_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 103 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "IMA +/-5V on/off The field takes one of the following values: 0 off 1 on" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "IMA_PLUS_30V_ON_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 105 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "IMA +30V on/off The field takes one of the following values: 0 off 1 on" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "IMA_PLUS_MINUS_12V_ON_OFF" DATA_TYPE = ASCII_INTEGER START_BYTE = 107 BYTES = 1 UNIT = "N/A" FORMAT = "I1" DESCRIPTION = "IMA +/-12V on/off The field takes one of the following values: 0 off 1 on" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "SW_MODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 109 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "Software mode" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "CPU_LOAD" DATA_TYPE = ASCII_INTEGER START_BYTE = 113 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "CPU load" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "IMA_LINK_STATUS" DATA_TYPE = ASCII_INTEGER START_BYTE = 117 BYTES = 3 UNIT = "N/A" FORMAT = "I3" DESCRIPTION = "It contains status register of IEEE 1355 LINK Chip. This field value has to be decoded in Binary format. Bit description: bit: 7: ndata0A bit 6: crdMEM bit 5: datav bit 4: resetm bit 3: ffrx bit 2: EOP1 bit 1: ndata0 bit 0: nm1 In typical nominal operation one should find value 0x41 on the link when link is working properly." END_OBJECT = COLUMN