PDS_VERSION_ID                 = PDS3                                         
                                                                              
RECORD_TYPE                    = FIXED_LENGTH                                 
RECORD_BYTES                   = 81                                           
FILE_RECORDS                   = 127                                          
                                                                              
                                                                              
/* DATA OBJECT POINTERS IDENTIFICATION DATA ELEMENTS    */                    
                                                                              
^TABLE                         = "TOK_COEF1504_ORB.TXT"                       
                                                                              
                                                                              
DATA_SET_ID                    = "MEX-M-SPI-2-IRRDR-CLEANED-EXT1-V1.0"        
DATA_SET_NAME                  = "MEX EXT1 SPICAM MARS CLEANED IR RDR V1.0"   
RELEASE_ID                     = 0001                                         
REVISION_ID                    = 0000                                         
                                                                              
                                                                              
PRODUCT_ID                     = "TOK_COEF1504_ORB.TXT"                       
PRODUCT_CREATION_TIME          = 2012-01-20                                   
MISSION_NAME                   = "MARS EXPRESS"                               
INSTRUMENT_HOST_NAME           = "MARS EXPRESS"                               
INSTRUMENT_HOST_ID             =  MEX                                         
PRODUCER_ID                    = MEX_SPI_TEAM                                 
PRODUCER_FULL_NAME             = "FRANCK MONTMESSIN"                          
PRODUCER_INSTITUTION_NAME      = "LATMOS,IPSL/CNRS,FRANCE"                    
INSTRUMENT_ID                  = SPICAM                                       
INSTRUMENT_NAME                = "SPICAM"                                     
INSTRUMENT_TYPE                = "SPECTROMETER"                               
                                                                              
DESCRIPTION                    = " For observations obtained with DAC : 1504  
                                   and GAIN : 3.0.                            
                                   The dark current is evaluted by linear     
                                   approximation D(F):a(F)*X+b(F)  where :    
                                   D   signal in ADU/gain factor,             
                                   X   temperature of detector in Volts       
                                   This file contains the coefficients a and b
                                   for each detector."                        
                                                                              
OBJECT                 = TABLE                                                
  INTERCHANGE_FORMAT   = ASCII                                                
  ROWS                 = 127                                                  
  ROW_BYTES            = 81                                                   
  COLUMNS              = 5                                                    
                                                                              
  OBJECT                 = COLUMN                                             
    NAME                 = FREQUENCY                                          
    DATA_TYPE            = FLOAT                                              
    START_BYTE           = 1                                                  
    BYTES                = 16                                                  
    DESCRIPTION          = "Frequency in MHz"                                 
  END_OBJECT             = COLUMN                                             
                                                                              
  OBJECT                 = COLUMN                                             
    NAME                 = A0                                                 
    DATA_TYPE            = FLOAT                                              
    START_BYTE           = 17                                                  
    BYTES                = 16                                                  
    DESCRIPTION          = "coefficent a for detector 0"                      
  END_OBJECT             = COLUMN                                             
                                                                              
  OBJECT                 = COLUMN                                             
    NAME                 = B0                                                 
    DATA_TYPE            = FLOAT                                              
    START_BYTE           = 33                                                  
    BYTES                = 16                                                  
    DESCRIPTION          = "coefficent b for detector 0"                      
  END_OBJECT             = COLUMN                                             
                                                                              
  OBJECT                 = COLUMN                                             
    NAME                 = A1                                                 
    DATA_TYPE            = FLOAT                                              
    START_BYTE           = 49                                                 
    BYTES                = 16                                                  
    DESCRIPTION          = "coefficent a for detector 1"                      
  END_OBJECT             = COLUMN                                             
                                                                              
  OBJECT                 = COLUMN                                             
    NAME                 = B1                                                 
    DATA_TYPE            = FLOAT                                              
    START_BYTE           = 65                                                 
    BYTES                = 16                                                  
    DESCRIPTION          = "coefficent b for detector 1"                      
  END_OBJECT             = COLUMN                                             
                                                                              
END_OBJECT = TABLE                                                            
                                                                              
END