/*----------------------------------------------------- /*SPU HLSW V11.5 - WHAT'S NEW !! /* /* Project: HSO/PACS, SPU HLSW /* Contact: spuhlsw@prip.tuwien.ac.at /* Date: 22-06-2005 /*----------------------------------------------------- SPU HLSW 11.5 is positioned as an upgrade of SPU HLSW 11.4, containing the following new features: * SPR 317 This will be explained in the specific sections that follow. The required Decompression SW version is: - Decompress11 (Ground Decompression Software in Java) The SPU HLSW Development Team. SPR 317 ------- The double compression mode in spectroscopy has provided corrupted data due to a wrong paramater used by the sorting algorithm "Reorder". This algorithm used the number of slopes before the integration while the number of integrated slopes has to be used. This bug has been alleviated in the OBSW but still additional tests must be performed to check whether this correction is enough or OBSW and/or decompression SW has to be further upgraded. Therefore, this SPR is still open. The following c/h files has been changed since HLSW version 11.4: - T_S_Red.c /* --- EOF ---