* HIFI_Readme C40_77 1. Date and time of delivery: 2011-04-26 19:00 2. HIFI individual(s) to be contacted where problems arise with the delivery: - Calibration Scientist: Ian Avruch - Calibration Scientist: Christophe Risacher - database administrator: Kevin Edwards 3. Cycle 40 - delivery for CAL CUS 4. delivery: - duration_cal.sh - HIFI_AOR_C040_75.aor - HIFI_AOR_C040_76.aor - HIFI_AOR_C040_77.aor - HIFI_DUR_C040_77.txt - HIFI_MC_R083_FULL_77_0_CUS_CAL.xml - HIFI_MC_R083_FULL_77_0_CUS.def - HIFI_Readme_C040_77.txt (this file) 5. configuration control a) HIFI_PHS_R_083 b) - c) hifiphs_ops_pv@iccdb1.sron.rug.nl d) hcss.dp.hifi: 6.0.2054 6. AOR file issues a) HSpot: 5.3.0, PHS: 661, MPS: 6.0.2054 b) 20 in HIFI_AOR_C040_77.aor 7 in HIFI_AOR_C040_76.aor 4 in HIFI_AOR_C040_75.aor c) HSpot total time: 13:20:51 7. Spacecraft database issues a) MIB 2154 b) HPSDB HPSDB_MOC_HERSCH_CCS_issueMOC9 c) OBSM 6.5.3 8. n/a 9. applicable SxRs: PHS-1622 HIFI-4083 HIFI-3354 HIFI-3981 10. Instruction for scheduling of calibration observations in HIFI cycle 40 A. Engineering tests The following tests should be performed as first tests during the DTCP. They should be scheduled against MC H77. HifiEng_Chopper_openloop_scan_cycle40 HifiEng_Chopper_Response_time_COP_cycle40 B. Diplexer calibration Quaterly checks Of the three AORs listed below, the first two should be performed during the DTCP. The third one will have to be scheduled after the DTCP. Each AOR contains its own LO switch-on. It starts with the LO band "a" and ends in the LO band "b". They should be scheduled against MC H77. During DTCP: HifiEng_Diplexer_calibration_vs_D2_COP_B3_QSFT4 HifiEng_Diplexer_calibration_vs_D2_COP_B4_QSFT4 Outside DTCP: HifiEng_Diplexer_calibration_vs_D2_COP_B6_QSFT4 C. HIFI Parametric scan tests These AORs could be executed during DTCP but it is anticipated that DTCP time will be used by the above diplexer tests. Those tests are in band 7b. They should be scheduled against MC H77. The indicated order below should be followed. HifiEngSwitchonLO_7b_SHORT_1897GHz_retune HifiEng_Parameter_Scan_COP_1829GHz_C40 HifiEng_Parameter_Scan_COP_1830GHz_C40 HifiEng_Parameter_Scan_COP_1831GHz_C40 HifiEng_Parameter_Scan_COP_1832GHz_C40 HifiEng_Parameter_Scan_COP_1833GHz_C40 HifiEng_Parameter_Scan_COP_1834GHz_C40 HifiEng_Parameter_Scan_COP_1835GHz_C40 HifiEng_Parameter_Scan_COP_1836GHz_C40 HifiEng_Parameter_Scan_COP_1837GHz_C40 HifiEng_Parameter_Scan_COP_1838GHz_C40 HifiEng_Parameter_Scan_COP_1839GHz_C40 D. Side-Band ratio checks The following tests consider pairs of AORs to be scheduled with different CAL CUS MC (resp. H75 and H77). AORs in a given band need to be scheduled together, i.e. (LO switch-on are not included in the following but are of course needed - SHORT switch-on are OK) Aot3_S_Proc_DBSFast_1a_520-553.4_R1_IRC10216_H75 Aot3_S_Proc_DBSFast_1a_520-553.4_R1_IRC10216_H77 Aot3_S_Proc_DBSFast_5a_Full_R1_IRC10216_H75 Aot3_S_Proc_DBSFast_5a_Full_R1_IRC10216_H77 Aot3_S_Proc_DBSFast_5b_Full_R1_IRC10216_H75 Aot3_S_Proc_DBSFast_5b_Full_R1_IRC10216_H77 E. Verification of HIFI-3354 This AOR needs to be scheduled against H75. Aot3_S_DBSNoC_1a_541-553_R12_HrsHi_IRC10216_SPR3354 F. Standard Source Monitoring Observations These astronomical targets are part of our monitoring program on reference sources. These seven AORs should be scheduled against the current ASTR MC (H76) AOT3_6a_CO_13_12_3x3_VY_cma_cycle_40 AOT3_5a_CO_10_9_3x3_VY_cma_cycle_40 AOT3_5a_CO_10_9_3x3_Ep_Aqr_cycle_40 AOT3_3b_CO_8_7_3x3_VY_cma_cycle_40 AOT3_3b_CO_8_7_3x3_Ep_Aqr_cycle_40 AOT3_2a_CO_6_5_3x3_VY_cma_cycle_40 AOT3_2a_CO_6_5_3x3_Ep_Aqr_cycle_40 11. execute supplied script './duration_cal.sh HIFI_AOR_C040_77.aor' in a directory where file HIFI_AOR_C040_77.aor exists and compare output (if any) with info listed under b) a) duration_cal.sh b) Total duration of HifiEng_Chopper_FT2_COP with default parameters = 114 Total duration of HifiEng_Chopper_Response_time_COP with default parameters = 44 Total duration of HifiEng_Diplexer_calibration_vs_D2_COP with default parameters = 5099 Total duration of HifiEng_Parameter_Scan_COP with default parameters = 921 Total duration of HifiEngSwitchonLO with default parameters = 428 Total duration of HifiSScanProcFastDBS with default parameters = 344