* HIFI_Readme C30_63 1. Date and time of delivery: 2010-12-09 16:00 2. HIFI individual(s) to be contacted where problems arise with the delivery: - Calibration Scientist: David Teyssier - database administrator: Kevin Edwards 3. Cycle 30 - delivery for CAL CUS 4. delivery: - HIFI_AOR_C030_63.aor - HIFI_DUR_C030_63.txt - HIFI_Readme_C030_63.txt (this file) - duration_cal.sh 5. configuration control a) HIFI_PHS_R_071 b) - c) hifiphs_ops_pv@iccdb1.sron.rug.nl d) hcss.dp.hifi: 5.0.1760 6. AOR file issues a) HSpot: 5.2.1, PHS: 648, MPS: 5.0.1760 b) 54 c) HSpot total time: 10:44:13 7. Spacecraft database issues a) MIB 2154 b) HPSDB HPSDB_MOC_HERSCH_CCS_issueMOC9_201003161700 c) OBSM 6.4.2 8. n/a 9. applicable SxRs: 10. Instruction for scheduling of calibration observations in HIFI cycle 30 A. HIFI quarterly SFTs Those AORs should be executed during a DTCP, and they do not need to point at any target. The indicated order below should be followed HifiEng_WBS_FT_COP_cycle30 HifiEng_HRS_FT_COP_cycle30 HifiEng_Chopper_openloop_scan_cycle30 HifiEng_Chopper_Response_time_COP_cycle30 HifiEng_Diplexer_Response_time_COP_3H_cycle30 HifiEng_Diplexer_Response_time_COP_3V_cycle30 HifiEng_Diplexer_Response_time_COP_4H_cycle30 HifiEng_Diplexer_Response_time_COP_4V_cycle30 HifiEng_Diplexer_Response_time_COP_B6H_cycle30 HifiEng_Diplexer_Response_time_COP_B6V_cycle30 HifiEng_Diplexer_Response_time_COP_B7H_cycle30 HifiEng_Diplexer_Response_time_COP_B7V_cycle30 HifiEng_FPU_FT_IVC_COP_B1_cycle30 HifiEng_FPU_FT_IVC_COP_B2_cycle30 HifiEng_FPU_FT_IVC_COP_B3_cycle30 HifiEng_FPU_FT_IVC_COP_B4_cycle30 HifiEng_FPU_FT_IVC_COP_B5_cycle30 HifiEng_FPU_FT_IVC_COP_B6_cycle30 HifiEng_FPU_FT_IVC_COP_B7_cycle30 HifiEng_LO_FT_IVC_COP_1a_cycle30 HifiEng_LO_FT_IVC_COP_1b_cycle30 HifiEng_LO_FT_IVC_COP_2a_cycle30 HifiEng_LO_FT_IVC_COP_2b_cycle30 HifiEng_LO_FT_IVC_COP_3a_cycle30 HifiEng_LO_FT_IVC_COP_3b_cycle30 HifiEng_LO_FT_IVC_COP_4a_cycle30 HifiEng_LO_FT_IVC_COP_4b_cycle30 HifiEng_LO_FT_IVC_COP_5a_cycle30 HifiEng_LO_FT_IVC_COP_5b_cycle30 HifiEng_LO_FT_IVC_COP_6a_cycle30 HifiEng_LO_FT_IVC_COP_6b_cycle30 HifiEng_LO_FT_IVC_COP_7a_cycle30 HifiEng_LO_FT_IVC_COP_7b_cycle30 B. Band 5a/5b purity test wrap-up The following tests contain one engineering part that can be scheduled in DTCP, and another part that needs to point towards a particular source. It is up to the mission planners to decide whether the observations in 5a can be combined to other KP AORs. IMPORTANT: one AOR needs to use the ASTR MC H64, as we are interested in the comparison of both MC. It is the one with label "_H64". The AORs should at least be grouped as follows (but the groups do not necessarily have to follow each others): HifiEngSwitchonLO_5a_SHORT HifiEng_Vecscan_calibration_5a_1135-1136GHz_cycle30 HifiEngSetIntoPrimary_After_B5a HifiEngSwitchonLO_5b_SHORT HifiEng_Vecscan_calibration_5b_1250-1258GHz_cycle30 Aot3_S_DBSFastNoC_5b_1235-1237_R3_NGC7027_H63 Aot3_S_DBSFastNoC_5b_1235-1237_R3_NGC7027_H64 --->>>> use ASTR MC H64 !!!!! HifiEngSetIntoPrimary_After_B5b C. Investigation of Tsys robustness in 6a around 1441 GHz (HIFI-3833) The following AOR does not need any band switch, and can be done in DTCP. It can be combined with other KP AORs in band 6a but it cannot serve as a band switch. HifiEng_Tsys_1441GHz_Investigation_Ticket3174 D. Follow-up of investigation for ticket 2972 (HIFI-3851) The following observations in band 4a can be combined with other KP AORs in this band. If there are no other AORs in this band, then a short LO switch-on is sufficient, provided the following order is scheduled: Aot3_P_DBSFastNoC_4a_0968_CarinaN Aot3_P_FSW_4a_0968_CarinaN Aot3_P_DBSFastNoC_4a_1004_CarinaN Aot3_P_FSW_4a_1004_CarinaN Aot3_P_PSW_0972-OH+-NH-H3O+_CarinaN Aot3_S_FSw_4a_967-1042_R4_CarinaN -> OPTIONAL E. Pointing tests The following tests should be combined, if possible, with observations in the same bands 5a and 6b. They need a dedicated LO switch-on in case it cannot be shared with other AORs in the same band. Provided the order below is followed, the switch-on can be SHORT in 5a. For 6b it has to be LONG, as usual. PointingTestDBS-RDor-5a PointingTestRasterDBS-RDor-5a PointingTestPS-RDor-5a PointingTestDBS-RDor-6b PointingTestRasterDBS-RDor-6b PointingTestPS-RDor-6b 11. execute supplied script 'duration_cal.sh HIFI_AOR_C030_63' in a directory where file HIFI_AOR_C030_63.aor exists and compare output (if any) with info listed under b) a) duration_cal.sh b) Total duration of HifiEng_Chopper_FT2_COP with default parameters = 114 Total duration of HifiEng_Chopper_Response_time_COP with default parameters = 44 Total duration of HifiEng_Diplexer_Response_time_COP with default parameters = 85 Total duration of HifiEng_FPU_FT_IVC_COP with default parameters = 65 Total duration of HifiEng_HRS_FT_COP with default parameters = 1101 Total duration of HifiEng_LO_FT_IVC_COP with default parameters = 227 Total duration of HifiEngSetIntoPrimary with default parameters = 6 Total duration of HifiEngSwitchonLO with default parameters = 401 Total duration of HifiEng_Tsys_COP with default parameters = 1533 Total duration of HifiEng_Vecscan_calibration_COP with default parameters = 2529 Total duration of HifiEng_WBS_FT_COP with default parameters = 1388 Total duration of HifiMappingProcDBSRaster with default parameters = 850 Total duration of HifiPointProcDBS with default parameters = 157 Total duration of HifiPointProcPositionSwitch with default parameters = 139 Total duration of HifiPointModeDBS with default parameters = 157 Total duration of HifiPointModeFastDBS with default parameters = 145 Total duration of HifiPointModeFSwitch with default parameters = 180 Total duration of HifiPointModeFSwitchNoRef with default parameters = 156 Total duration of HifiPointModeLoadChop with default parameters = 147 Total duration of HifiPointModeLoadChopNoRef with default parameters = 123 Total duration of HifiPointModePositionSwitch with default parameters = 139 Total duration of HifiMappingModeDBSCross with default parameters = 497 Total duration of HifiMappingModeDBSRaster with default parameters = 233 Total duration of HifiMappingModeFastDBSCross with default parameters = 425 Total duration of HifiMappingModeFastDBSRaster with default parameters = 209 Total duration of HifiMappingModeFSwitchOTF with default parameters = 235 Total duration of HifiMappingModeFSwitchOTFNoRef with default parameters = 162 Total duration of HifiMappingModeLoadChopOTF with default parameters = 202 Total duration of HifiMappingModeLoadChopOTFNoRef with default parameters = 129 Total duration of HifiMappingModeOTF with default parameters = 168 Total duration of HifiSScanModeDBS with default parameters = 386 Total duration of HifiSScanModeFastDBS with default parameters = 338 Total duration of HifiSScanModeFSwitch with default parameters = 500 Total duration of HifiSScanModeFSwitchNoRef with default parameters = 417 Total duration of HifiSScanModeLoadChop with default parameters = 350 Total duration of HifiSScanModeLoadChopNoRef with default parameters = 285