* HIFI_Readme C027_61 1. Date and time of delivery: 2010-10-29 16:00 2. HIFI individual(s) to be contacted where problems arise with the delivery: - Calibration Scientist: David Teyssier - database administrator: Kevin Edwards 3. Cycle 27 - delivery for CAL CUS 4. delivery: - HIFI_MC_R069_FULL_61_0_CUS.def - HIFI_MC_R069_FULL_61_0_CUS_CAL.xml - HIFI_AOR_C027_61.aor - HIFI_DUR_C027_61.txt - HIFI_Readme_C027_61.txt (this file) - duration_cal.sh 5. configuration control a) HIFI_PHS_R_069 b) - c) hifiphs_ops_pv@iccdb1.sron.rug.nl d) hcss.dp.hifi: 4.0.1349 6. AOR file issues a) HSpot: 5.1.1, PHS: 630, MPS: 4.0.1349 b) 19 c) HSpot total time: 04:24:50 7. Spacecraft database issues a) MIB 2154 b) HPSDB HPSDB_MOC_HERSCH_CCS_issueMOC9_201003161700 c) OBSM 6.4.2 8. n/a 9. applicable SxRs: - HIFI-3796 - PHS-1551 - HIFI-3787 10. Instruction for scheduling of calibration observations in HIFI cycle 27 A. Multiple COMB tests. This AOR can be scheduled during DTCP as it does not require any target. It shall be repeated in each DTCP, therefore it is delivered three times here. HifiEng_MultipleComb_COP_OD1_cycle27 HifiEng_MultipleComb_COP_OD2_cycle27 HifiEng_MultipleComb_COP_OD3_cycle27 B. Purity tests in bands 5a/5b The following AORs can be done in DTCP. They do not require any target. Note that the tests in each band are ended with a transition to Primary. This is a precautionary measure taken in case the test fails and brings the instrument into a failure mode. HifiEngSwitchonLO_5a_SHORT_MTL HifiEng_Vecscan_5a_Purity_1128-1142_cycle27 HifiEng_Tsys_5a_purity_1128-1142_cycle27 HifiEngSetIntoPrimary_After_B5a HifiEngSwitchonLO_5b_SHORT_MTL HifiEng_Vecscan_5b_Purity_1235-1242_cycle27 HifiEng_Tsys_5b_purity_1235-1242_cycle27 HifiEngSetIntoPrimary_After_B5b C. HRS/WBS FCal cross-calibration tests The following tests are performed in bands 1b and 7b. They should be grouped by band at least, as suggested in the following. Band switches are not included in the delivery as it is assumed that other astronomical observations will take place in the same band. If not, use a SHORT LO switch-on. Band 1b: Aot3_P_DBSNoC_1b_CO_5_4_CarinaS-IRAS10430 Aot3_P_DBSNoC_1b_CO_5_4_FCal_CarinaS-IRAS10430 Band 7b: Aot3_P_DBSNoC_7b_CII_CarinaS-IRAS10430 Aot3_P_DBSNoC_7b_CII_FCal_CarinaS-IRAS10430 D. Investigation for ticket 2972 The following tests are performed in bands 4a. The band switch is not included in the delivery as it is assumed that other astronomical observations will take place in the same band. The following order should be respected: Aot3_P_DBSFastNoC_0972-OH+-NH-H3O+_CarinaN Aot3_P_LChop_0972-OH+-NH-H3O+_CarinaN Aot3_P_FSW_0972-OH+-NH-H3O+_CarinaN Aot3_P_FSW_0984_LSB-H3O+_CarinaN 11. execute supplied script 'duration_cal.sh HIFI_AOR_C027_61' in a directory where file HIFI_AOR_C027_61.aor exists and compare output (if any) with info listed under b) a) duration_cal.sh b) Total duration of HifiEng_MultipleComb_COP with default parameters = 36 Total duration of HifiEngSetIntoPrimary with default parameters = 6 Total duration of HifiEngSwitchonLO with default parameters = 401 Total duration of HifiEng_Tsys_COP with default parameters = 1533 Total duration of HifiEng_Vecscan_calibration_COP with default parameters = 2529 Total duration of HifiPointProcDBS_FCal with default parameters = 159 Total duration of HifiPointProcDBS with default parameters = 157 Total duration of HifiPointModeDBS with default parameters = 157 Total duration of HifiPointModeFastDBS with default parameters = 145 Total duration of HifiPointModeFSwitch with default parameters = 180 Total duration of HifiPointModeFSwitchNoRef with default parameters = 156 Total duration of HifiPointModeLoadChop with default parameters = 147 Total duration of HifiPointModeLoadChopNoRef with default parameters = 123 Total duration of HifiPointModePositionSwitch with default parameters = 139