* HIFI_Readme C026_59 1. Date and time of delivery: 2010-10-14 12:00 2. HIFI individual(s) to be contacted where problems arise with the delivery: - Calibration Scientist: David Teyssier - database administrator: Kevin Edwards 3. Cycle 26 - delivery for CAL CUS 4. delivery: - HIFI_MC_R068_FULL_59_0_CUS.def - HIFI_MC_R068_FULL_59_0_CUS_CAL.xml - HIFI_AOR_C026_59.aor - HIFI_DUR_C026_59.txt - HIFI_Readme_C026_59.txt (this file) - duration_cal.sh 5. configuration control a) HIFI_PHS_R_068 b) - c) hifiphs_ops_pv@iccdb1.sron.rug.nl d) hcss.dp.hifi: 4.0.1349 6. AOR file issues a) HSpot: 5.1.1, PHS: 630, MPS: 4.0.1349 b) 26 c) HSpot total time: 08:36:22 7. Spacecraft database issues a) MIB 2154 b) HPSDB HPSDB_MOC_HERSCH_CCS_issueMOC9_201003161700 c) OBSM 6.4.2 8. n/a 9. applicable SxRs: - HIFI-3327 - HIFI-1313 - HIFI-3633 - HIFI-3787 10. Instruction for scheduling of calibration observations in HIFI cycle 26 For this cycle, only 2 AORs do not require a target, and therefore can fit a priori into DTCPs (others could but this depends on where the targets are at the time of observation). A. Band 1a purity checks This AOR has to be ideally scheduled together with other observations in this band. As such, no LO switch-on AOR is delivered, but if this AOR is the only one scheduled in band 1a, a band switch-on has to be added. Note that if this observation is performed together with other AORs in band 1a, this calibration AOR should be scheduled LAST. Aot3_S_DBSNoC_1a_538-544_R8_NGC7023 B. Purity tests in bands 5a/5b The following AORs should start in DTCP, then continue outside DTCP if the source IRC+10216 is not visible during the DTCP at the time of schedule. The order shown below is indicative and can be optimised by the mission planners if possible. Note that the tests in each band are ended with a transition to Primary. This is a precautionary measure taken in case the test fails and brings the instrument into a failure mode. HifiEngSwitchonLO_5a_SHORT_MTL HifiEng_Vecscan_5a_Purity2_cycle26 HifiEng_Tsys_5a_purity2_cycle26 HifiEngSetIntoPrimary_After_B5a HifiEngSwitchonLO_5b_SHORT_MTL HifiEng_Vecscan_5b_Purity2_cycle26 Aot3_S_DBSFastNoC_5b_Full_R3_IRC10216 HifiEngSetIntoPrimary_After_B5b C. HRS/WBS FCal cross-calibration tests The following tests are performed in bands 1b and 7b. They should be grouped by band at least, as suggested in the following. Band switches are not included in the delivery as it is assumed that other astronomical observations will take place in the same band. Band 1b: Aot3_P_DBS_1b_CO_5_4_CarinaS-IRAS10430 Aot3_P_DBSNoC_1b_CO_5_4_FCal_CarinaS-IRAS10430 Aot3_P_DBS_1b_CO_5_4_NGC7023 Aot3_P_DBSNoC_1b_CO_5_4_FCal_NGC7023 Aot3_P_LChopNoRef_1b_CO_5_4_NGC7023 Aot3_P_LChopNoRef_1b_CO_5_4_FCal_NGC7023 Band 7b: Aot3_P_DBS_7b_CII_CarinaS-IRAS10430 Aot3_P_DBSNoC_7b_CII_FCal_CarinaS-IRAS10430 Aot3_P_DBS_7b_CII_NGC7023 Aot3_P_DBSNoC_7b_CII_FCal_NGC7023 D. Investigation for ticket 2972 The following tests are performed in bands 4a. The band switch is not included in the delivery as it is assumed that other astronomical observations will take place in the same band. The following order should be respected: Aot3_P_DBSFastNoC_0972-OH+-NH-H3O+_CarinaN Aot3_P_LChop_0972-OH+-NH-H3O+_CarinaN Aot3_P_FSW_0972-OH+-NH-H3O+_CarinaN Aot3_P_FSW_0984_LSB-H3O+_CarinaN E. OTF investigation The following tests are performed in bands 1b. The band switch is not included in the delivery as it is assumed that other astronomical observations will take place in the same band (possibly together with the tests in item C). Aot3_M_OTF_1b_CO5-4_IRC10216_halfbeam Aot3_M_OTF_1b_CO5-4_IRC10216_rotated Aot3_M_OTF_1b_CO5-4_IRC10216 11. execute supplied script 'duration_cal.sh HIFI_AOR_C026_59' in a directory where file HIFI_AOR_C026_59.aor exists and compare output (if any) with info listed under b) a) duration_cal.sh b) Total duration of HifiEngSetIntoPrimary with default parameters = 6 Total duration of HifiEngSwitchonLO with default parameters = 401 Total duration of HifiEng_Tsys_COP with default parameters = 1533 Total duration of HifiEng_Vecscan_calibration_COP with default parameters = 2529 Total duration of HifiPointProcDBS_FCal with default parameters = 159 Total duration of HifiPointProcDBS with default parameters = 157 Total duration of HifiPointProcLoadChopNoRef_FCal with default parameters = 125 Total duration of HifiPointProcLoadChopNoRef with default parameters = 123 Total duration of HifiPointModeDBS with default parameters = 157 Total duration of HifiPointModeFastDBS with default parameters = 145 Total duration of HifiPointModeFSwitch with default parameters = 180 Total duration of HifiPointModeFSwitchNoRef with default parameters = 156 Total duration of HifiPointModeLoadChop with default parameters = 147 Total duration of HifiPointModeLoadChopNoRef with default parameters = 123 Total duration of HifiPointModePositionSwitch with default parameters = 139 Total duration of HifiMappingModeDBSCross with default parameters = 497 Total duration of HifiMappingModeDBSRaster with default parameters = 233 Total duration of HifiMappingModeFastDBSCross with default parameters = 425 Total duration of HifiMappingModeFastDBSRaster with default parameters = 209 Total duration of HifiMappingModeFSwitchOTF with default parameters = 235 Total duration of HifiMappingModeFSwitchOTFNoRef with default parameters = 162 Total duration of HifiMappingModeLoadChopOTF with default parameters = 202 Total duration of HifiMappingModeLoadChopOTFNoRef with default parameters = 129 Total duration of HifiMappingModeOTF with default parameters = 168 Total duration of HifiSScanModeDBS with default parameters = 386 Total duration of HifiSScanModeFastDBS with default parameters = 338 Total duration of HifiSScanModeFSwitch with default parameters = 500 Total duration of HifiSScanModeFSwitchNoRef with default parameters = 417 Total duration of HifiSScanModeLoadChop with default parameters = 350 Total duration of HifiSScanModeLoadChopNoRef with default parameters = 285