README CONTENTS The Readme file shall consist of the following fields. 1. Date & Time of delivery 26th August 2010 18:00 BST 2. ICC individual to be contacted where problems arise with the delivery (1) Tanya Lim (RAL) Note: always copy spire@stfc.ac.uk 3. Cycle for which the data being delivered is applicable. Cycle 023 4. Delivery information - names of all files contained in the tar file SPIRE_AOR_C023_59_CAL.aor SPIRE_AOR_C023_59_ENG.aor SPIRE_CUS_THCP.py SPIRE_Duration.txt SPIRE_Readme_C023_58.txt SPIRE_MC_pv85_C023_58_CUS_CAL.xml SPIRE_MC_pv85_C023_58_CUS.def 5. Cus Script & Calibration files ICC internal configuration control issues (a) Name of ICC mission configuration from which files were exported (for reference purposes only) pvPhase_mconfig_85 (b) Name of the CVS Tag related to this delivery (if relevant) N/A (c) Name of the ICC Database containing this delivery (for reference purposes only) mps_phs_1 (d) HCSS Cus version used when working with these files 1528 6. AOR File issues (a) HSpot, PHS & MPS versions used : Note if you don't use MPS then no need to mention it HSpot 5.0.5 PHS 626 over 1579 (HCSS 3.0.0), MPS 1528, HCSS 2.0.1 (b) Number of AOR files delivered in the .aor file CAL:5 ENG:3 (c) Overall Time Estimation calculated by HSpot - In Hours, Minutes & Seconds CAL: 1:16:28 ENG: 0:35:38 7. Spacecraft Database issues (a) ICC MIB version applicable to these cus & calibration files SPIRE 4.0.02 PR (b) HPSDB version (if known) that contains this MIB HPSDB_MOC_HERSCH_CCS_issueMOC5_200910261200 (c) OBSM software version on the instrument applicable to this MIB the one currently loaded on the S/C 8. Go-ahead of the ICC CCB (if applicable) SPIRE gives go ahead 9. SxRs applicable to the updates of the scripts delivered in this release - If there is an ASTR Mission Configuration delivery, then flag the high level SxR which contains the list of SxRs since the last ASTR delivery that affect a released AOT + list other SxRs that are calibration MC specific + High level SXRs: SPIREScr:2779 + Astronomer AOT SxRs: SPIREScr:2778 + Expert AOT SxRs: N/A 10. Additional notes (a) Update Information : If this corresponds to an update since the last delivery, explain what the updates consist of e.g. 2 more AORs added. This astronomer mission configuration supports bright source mode for the spectrometer. Note only the photometer is being used in cycle 23 therefore the earliest day this will affect will be OD 514 although if possible this could be put into the end of cycle 22 on OD 494. (b) Instructions for the Mission Planners A list with all the solar system objects that are going to be observed. This will include specification of the constraints (if any) that has to be modified in the MPS properties file. 1 Ceres #SPIRE (in REDY mode) observations for OD 498 or 499# ============================================== Scheduling instructions (for obs marked with '*'): -------------------------------------------------- This AOR should be scheduled about bi-weekly (14+-3 days) in an 'unused' DTCP time-slot when real time science is available. As suggested at planning meeting #50 this could be in the DTCP RTSW of a 2nd or 3rd non-cooler recycling PACS photometry OD. So we suggest OD 498 or 499. It should be done during science time. Observations: ------------- - No Pointing: A:*SpireEngDumpMemoryGen Justifications: --------------- A: A health monitoring AOR to be added to the SPIRE RCal Plan. #SPIRE-P observations for OD 500-501# ===================================== Scheduling instructions (for obs marked with '*'): -------------------------------------------------- Note, after the REDY2STBY there is no longer the need to wait any time before the first science observation can be scheduled. However, it would still be nice if you could move any left-over seconds in the schedule to right after the REDY2STBY. Observations: ------------- A: SPhoto-SmallM-Rep4-GammaDra A: SPhoto-PointS-Rep4-GammaDra A: SPhoto-SmallM-Rep4-EpsLep A: SPhoto-SmallM-Rep4-Ceres A: SPhoto-SmallM-Rep4-DarkSky A: SpirePhoto_Cal_StdLoadCurveGen-DarkSky-PSWE6 Justifications: --------------- A: Covered by RCal Plan #SPIRE-S observations for OD 482# ================================ Scheduling instructions (for obs marked with '*'): -------------------------------------------------- This observation should be scheduled for those cycles where no spectrometer day is present (currently odd numbered cycles 21, 23, 25 etc). This AOR could be scheduled in an 'unused' DTCP time-slot when real time science is available. This script must be run from SPIRE REDY mode and does not require the instrument to be cold. It should be run approximately 14 days before and after each SPIRE spectrometer day so this should ideally be done on OD 508 but either 507 or 509 would be fine. Observations: ------------- A:*SpireEngSmecScanGen Justifications: --------------- A: Covered by RCal Plan 11. CusCmdscript output file (see note below) (a) Name of CusCmdScript SPIRE_CUS_THCP.py (b) Expected durations when this is run SPIRE_Duration.txt