* HIFI_Readme C021_53 1. Date and time of delivery: 2010-08-03 16:00 2. HIFI individual(s) to be contacted where problems arise with the delivery: - Calibration Scientist: David Teyssier - database administrator: Kevin Edwards 3. Cycle 21 - delivery for CAL CUS 4. delivery: - HIFI_MC_R064_FULL_53_0_CUS.def - HIFI_MC_R064_FULL_53_0_CUS_CAL.xml - HIFI_AOR_C021_53.aor - HIFI_DUR_C021_53.txt - HIFI_Readme_C021_53.txt (this file) - duration_cal.sh 5. configuration control a) HIFI_PHS_R_064 b) - c) hifiphs_ops_pv@iccdb1.sron.rug.nl d) hcss.dp.hifi: 4.0.1317 6. AOR file issues a) HSpot: 5.0.5, PHS: 626, MPS: 3.0.1579 b) 40 c) HSpot total time: 11:07:46 7. Spacecraft database issues a) MIB 2154 b) HPSDB HPSDB_MOC_HERSCH_CCS_issueMOC9_201003161700 c) OBSM 6.4.1 8. n/a 9. applicable SxRs: - HIFI-3633 - HIFI-3701 - PHS-1494 10. Instruction for scheduling of calibration observations in HIFI cycle 21 A. Quarterly functional tests (DTCP only) The following observations should be scheduled in the indicated order, preferably in one single DTCP. None of them does switch-on an LO band, however the LO_FT_IVC do switch off the LOU, so that a transition to dissipative-II is needed when this series is finished (see below). (HifiEngSetIntoPrimary -> not delivered by HIFI) HifiEng_Chopper_Response_time_COP_cycle21 HifiEng_Diplexer_Response_time_COP_3H_cycle21 HifiEng_Diplexer_Response_time_COP_3V_cycle21 HifiEng_Diplexer_Response_time_COP_4H_cycle21 HifiEng_Diplexer_Response_time_COP_4V_cycle21 HifiEng_Diplexer_Response_time_COP_B6H_cycle21 HifiEng_Diplexer_Response_time_COP_B6V_cycle21 HifiEng_Diplexer_Response_time_COP_B7H_cycle21 HifiEng_Diplexer_Response_time_COP_B7V_cycle21 HifiEng_FPU_FT_IVC_COP_B1_cycle21 HifiEng_FPU_FT_IVC_COP_B2_cycle21 HifiEng_FPU_FT_IVC_COP_B3_cycle21 HifiEng_FPU_FT_IVC_COP_B4_cycle21 HifiEng_FPU_FT_IVC_COP_B5_cycle21 HifiEng_FPU_FT_IVC_COP_B6_cycle21 HifiEng_FPU_FT_IVC_COP_B7_cycle21 HifiEng_LO_FT_IVC_COP_1a_cycle21 HifiEng_LO_FT_IVC_COP_1b_cycle21 HifiEng_LO_FT_IVC_COP_2a_cycle21 HifiEng_LO_FT_IVC_COP_2b_cycle21 HifiEng_LO_FT_IVC_COP_3a_cycle21 HifiEng_LO_FT_IVC_COP_3b_cycle21 HifiEng_LO_FT_IVC_COP_4a_cycle21 HifiEng_LO_FT_IVC_COP_4b_cycle21 HifiEng_LO_FT_IVC_COP_5a_cycle21 HifiEng_LO_FT_IVC_COP_5b_cycle21 HifiEng_LO_FT_IVC_COP_6a_cycle21 HifiEng_LO_FT_IVC_COP_6b_cycle21 HifiEng_LO_FT_IVC_COP_7a_cycle21 HifiEng_LO_FT_IVC_COP_7b_cycle21 (HifiEngSetIntoDissipativeII_bandX -> not delivered by HIFI) NOTE: bandX should correspond to the band that will be used first after the DTCP activities are completed. HifiEng_HRS_FT_COP_cycle21 HifiEng_WBS_FT_COP_cycle21 B. Engineering observation with no pointing (DTCP only) The following AORs should be scheduled during DTCP. They use band 1a. Ideally they can be schedule on a DTCP where the following science is also in band 1a, but this is not a pre-requisite. HifiEngSwitchonLO_1a_SHORT__cycle21 HifiEng_Tsys_Vecscan_M1_COP_1a_cycle21 C. Quarterly diplexer calibration (DTCP only) The following 4 AORs should be scheduled in ONLY if there is no science observation from HIFI that can be performed during the remaining DTCP time of cycle 21. In other words, science has priority over those AORs. If they are not scheduled in cycle21, we will submit them again for cycle 22. If there are windows in which they can be scheduled in DTCPs, please chose the bands that make sense with the science activities outside the DTCP. Please note that each of those AORs ends with the LO band "b" switched on. HifiEng_Diplexer_calibration_vs_D2_COP_B3_cycle21 HifiEng_Diplexer_calibration_vs_D2_COP_B4_cycle21 HifiEng_Diplexer_calibration_vs_D2_COP_B6_cycle21 HifiEng_Diplexer_calibration_vs_D2_COP_B7_cycle21 D. Observations outside the DTCP (unless visibility allows it): The following 2 AORs are probably only schedulable outside DTCP. Try to combine with other use of the same band. If no science observation in this cycle coincide with either bands 1a and/or 6a, please add the usual LO switch-on AOR before. Aot3_P_FastDBSNoC_6a_CH_1471_OrionKLHC CoP_SScan_1a_spur_Cycle21 11. execute supplied script 'duration_cal.sh HIFI_AOR_C021_53' in a directory where file HIFI_AOR_C021_53.aor exists and compare output (if any) with info listed under b) a) duration_cal.sh b) Total duration of HifiEng_Chopper_Response_time_COP with default parameters = 44 Total duration of HifiEng_Diplexer_calibration_vs_D2_COP with default parameters = 5081 Total duration of HifiEng_Diplexer_Response_time_COP with default parameters = 85 Total duration of HifiEng_FPU_FT_IVC_COP with default parameters = 62 Total duration of HifiEng_HRS_FT_COP with default parameters = 1101 Total duration of HifiEng_LO_FT_IVC_COP with default parameters = 209 Total duration of HifiEngSwitchonLO with default parameters = 395 Total duration of HifiEng_Tsys_Vecscan_M1_COP with default parameters = 4388 Total duration of HifiEng_WBS_FT_COP with default parameters = 1388 Total duration of HifiPointModeDBS with default parameters = 154 Total duration of HifiPointModeFastDBS with default parameters = 142 Total duration of HifiPointModeFSwitch with default parameters = 177 Total duration of HifiPointModeFSwitchNoRef with default parameters = 153 Total duration of HifiPointModeLoadChop with default parameters = 144 Total duration of HifiPointModeLoadChopNoRef with default parameters = 120 Total duration of HifiPointModePositionSwitch with default parameters = 136 Total duration of HifiSScanModeDBS with default parameters = 383 Total duration of HifiSScanModeFastDBS with default parameters = 335 Total duration of HifiSScanModeFSwitch with default parameters = 497 Total duration of HifiSScanModeFSwitchNoRef with default parameters = 414 Total duration of HifiSScanModeLoadChop with default parameters = 347 Total duration of HifiSScanModeLoadChopNoRef with default parameters = 282