HIFI Cycle 19 Cal and MC delivery HIFI Delivery note - 6th June 2010 Dear HSC Colleagues, This e-mail is to notify you that HIFI ICC has just uploaded the tar file containing the delivery of HIFI observations for cycle 16 onto the CVS server. 1. Delivery file, directory: a) OD tar file names: - CYCLE019_HIFI_FULL_1_20100706.tar b) CVS server directory: - develop/data/observingmodes/rp_cycles/cycle019 2. Mission Configurations: a) Does this delivery include a new Calibration Mission configuration? Yes b) Does this delivery include a new Astro Mission configuration? No 3. Operations Issues a) Will any of these delivered observations generate a significant amount of Telecommands? No b) Do you wish to have these calibrations observations scheduled in the Real Time Science period of the DTCP? Stability measurements to be scheduled during DTCP periods. c) ICC to add anything specific to this OD which HSC & MOC should be aware of: Instructions are in the Readme file. Please acknowledge receipt of the e-mail and the delivery. Kind regards, Christophe Take Note of the Tar File & the New MC name (for MPS email and for steps below) CYCLE019_HIFI_FULL_1_20100706.tar New MC - MC H49_Cal 2. Software used for import + Source the Environment (if not already done!!) HCSS SOFTWARE = 2.0.1 (Always use the most recent HCSS Software version) PHS SOFTWARE = 5.0.5_PHS (Always use the most recent PHS Software version) Herjbo02 - HCSS_PHS_TEST_herjbo02_0_6_6.props file & source .minimal_herjbo02 : PHS: Using BUILDNUM 534 & PHS: Using JBOSS_HOME /usr/local/software/jboss/jboss-3.2.6_0_6_5 Machines used : - heropl02 - hscphs2 for the uplink co-ord part - heropl02 - hscphs2 for the PropHandler - heropl01 - hscmps1 for the MPS - herjbo02 - hsc_phs account Source the Environment before you proceed to step 3. hscphs2@heropl02/home/hscphs2/otherSetups> source setHcssEnvironment_v2.0.1 TAKE NOTE : If there is a newer HCSS software version in the otherSetups directory then source that new version. 3. What is the Mission Configuration Name going to be?? MC_H49_P54_S56_CAL 4. Make the directories in the delivery directory and MC directory) hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19> ls HIFI/ logs/ PACS/ SPIRE/ hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI> mkdir HIFI_FULL_1 This LOG file has been placed in the /logs directory and given the name Cycle019_HIFI_FULL_1.log. hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL> mkdir PACS hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL> mkdir SPIRE hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL> mkdir HIFI hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL> mkdir logs hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL> ls HIFI/ logs/ PACS/ SPIRE/ 5. Copy across the contents of the PACS directory from a previous mission_config subdirectory into the equivalent subdirectories of the MC_H49_P54_S56_CAL folder. Next remove in the subfolders all files which were created when you ran the HIFI, SPIRE & PACS duration files e.g. tmp, SPIRE_cus_scipts, SPIRE_harness etc etc. PACS hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> cp /home/hscphs2/icchsc/mission_config/MC_H48ASTR_P54ASTR_S55ASTR_RP/PACS/* . hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> ls 2createOBSMODtable4RP.sh* PACS_Duration_PACS_2_compare.txt PACS_Readme_C017_54.txt CYCLE017_PACS_FULL_3_20100617.tar PACS_Duration_PACS.txt tmp msgPacsLineSpec.txt PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml tmpobsmode PACS_AOR_C017_54.aor PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS.def hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> rm tmp* msg* PACS_Duration_PACS.txt rm: remove regular file `tmp'? y rm: remove regular file `tmpobsmode'? y rm: remove regular file `msgPacsLineSpec.txt'? y rm: remove regular file `PACS_Duration_PACS.txt'? y hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> ls 2createOBSMODtable4RP.sh* PACS_Duration_PACS_2_compare.txt PACS_Readme_C017_54.txt CYCLE017_PACS_FULL_3_20100617.tar PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml PACS_AOR_C017_54.aor PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS.def SPIRE hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> cp /home/hscphs2/icchsc/mission_config/MC_H43_P50_S56_CAL/SPIRE/* . hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> ls CYCLE015_SPIRE_UPDATE_1_1_20100520.tar SPIRE_harness_duration_summary_20100521_12h06m32s.log SPIRE_AOR_C015_56_ENG.aor SPIRE_MC_pv82_C015_56_CUS_CAL.xml SPIRE_cus_scripts.txt SPIRE_MC_pv82_C015_56_CUS.def SPIRE_CUS_THCP.py SPIRE_Readme_C015_56.txt SPIRE_Duration.txt 6(a) Download & Untar the delivery from the CVS into the new mission_config directory (& the delivery directory) hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> setenv CVSROOT :pserver:lorourke@cvs.rssd.esa.int:/services/repositories/HERSCHEL_CVS hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> cvs login Logging in to :pserver:lorourke@cvs.rssd.esa.int:2401/services/repositories/HERSCHEL_CVS CVS password: hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> cvs co develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_20100706.tar U develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_20100706.tar hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> cp develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_20100706.tar . hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> ls CYCLE019_HIFI_FULL_1_20100706.tar develop/ hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> tar -xvf CYCLE019_HIFI_FULL_1_20100706.tar HIFI_AOR_C019_49.aor HIFI_DUR_C019_49.txt HIFI_MC_R062_FULL_49_0_CUS_CAL.xml HIFI_MC_R062_FULL_49_0_CUS.def HIFI_Readme_C019_49.txt duration_cal.sh hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> ls CYCLE019_HIFI_FULL_1_20100706.tar HIFI_AOR_C019_49.aor HIFI_MC_R062_FULL_49_0_CUS.def develop/ HIFI_DUR_C019_49.txt HIFI_Readme_C019_49.txt duration_cal.sh* HIFI_MC_R062_FULL_49_0_CUS_CAL.xml hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1> cp * /home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI/ cp: omitting directory `develop' hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls CYCLE019_HIFI_FULL_1_20100706.tar HIFI_AOR_C019_49.aor HIFI_MC_R062_FULL_49_0_CUS_CAL.xml HIFI_Readme_C019_49.txt duration_cal.sh* HIFI_DUR_C019_49.txt HIFI_MC_R062_FULL_49_0_CUS.def 6(b) To import the old PACS delivery: #CUS #var.hcss.instrument = SPIRE var.hcss.instrument = PACS #var.hcss.instrument = HIFI hcss.cus.model = FLIGHT Check with CUSGUI hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> Jul 6, 2010 4:18:05 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:18:09 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:18:10 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:18:10 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:18:10 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:18:10 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:18:10 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from PACS, specified by property hcss.cus.instrument Jul 6, 2010 4:18:22 PM herschel.cus.gui.CusEditor exit INFO: Quitting. TAKE NOTE : CONFIRM THAT PACS IS THE INSTRUMENT MODEL IN THE CUSGUI OUTPUT : CONFIRMED!!!! 6(c) Clean the CUS & Cal tables from the instrument model hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> cus -f -m "clean PACS CUS from DB" -deleteall Jul 6, 2010 4:19:05 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:19:06 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:19:07 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:19:07 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:19:07 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:19:07 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:19:18 PM herschel.cus.gui.Cus infoMessage INFO: All definitions have been deleted hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> cus -f -m "clean PACS CAL from DB" -caldeleteall Jul 6, 2010 4:19:32 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:19:33 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:19:33 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:19:33 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:19:33 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:19:33 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:19:38 PM herschel.cus.gui.Cus infoMessage INFO: All calibration tables successfully deleted TAKE NOTE : OPEN UP CUSGUI & VERIFY IT IS EMPTY i.e. No Cus scripts & No Parameter tables - VERIFIED!!! TAKE NOTE : Check HPSDB in the CUSGUI Session = hpsdb_MOC9_201003161700 - CONFIRMED!! 6(d) Import the new Instrument CUS & Cal tables into the DB Import new Mission Configuration (Version 54.0). hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> cus -m "upload PACS_MC_54ASTR mission config as Cal" -import PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS.def -importcaltables PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml Jul 6, 2010 4:22:15 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:22:16 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:22:16 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:22:16 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:22:16 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:22:16 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:22:42 PM herschel.cus.gui.Cus infoMessage INFO: Definitions successfully imported Jul 6, 2010 4:22:42 PM herschel.cus.gui.Cus infoMessage INFO: Using current directory Jul 6, 2010 4:22:43 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:22:43 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:22:43 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:22:43 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:22:48 PM herschel.cus.gui.Cus infoMessage INFO: Calibration tables successfully imported from "PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml" TAKE NOTE : The file referred to at the end import message shall correspond to the file that was delivered by PACS: PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml CONFIRMED!! PACS did not deliver AORs, so skip this next bit... 6(e) Run the duration script for the PACS instrument model: Open duration script (2createOBSMODtable4RP.sh) and point it to HCSS 2.0.1 hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> ./2createOBSMODtable4RP.sh PACS PACS_AOR_C017_54.aor /home/hscphs2/.hcss/Uplink_Coord.props /home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> ls -ls total 10924 4 -rwxr-xr-- 1 hscphs2 herschel 1538 Jun 17 14:28 2createOBSMODtable4RP.sh* 5452 -rw-r--r-- 1 hscphs2 herschel 5570560 Jun 17 12:51 CYCLE017_PACS_FULL_3_20100617.tar 0 -rw-r--r-- 1 hscphs2 herschel 62 Jul 6 16:25 msgPacsLineSpec.txt 28 -rw-r--r-- 1 hscphs2 herschel 24796 Jun 17 12:19 PACS_AOR_C017_54.aor 4 -rw-r--r-- 1 hscphs2 herschel 310 Jun 17 12:25 PACS_Duration_PACS_2_compare.txt 4 -rw-r--r-- 1 hscphs2 herschel 310 Jul 6 16:25 PACS_Duration_PACS.txt 400 -rw-r--r-- 1 hscphs2 herschel 404091 Jun 17 12:21 PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS_CAL.xml 5020 -rw-r--r-- 1 hscphs2 herschel 5128161 Jun 17 12:21 PACS_MC_ASTR_OT1_2010-06-16A_C017_54_CUS.def 4 -rw-r--r-- 1 hscphs2 herschel 4006 Jun 17 12:32 PACS_Readme_C017_54.txt 4 -rw-r--r-- 1 hscphs2 herschel 194 Jul 6 16:25 tmp 4 -rw-r--r-- 1 hscphs2 herschel 65 Jul 6 16:25 tmpobsmode hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> diff PACS_Duration_PACS_2_compare.txt PACS_Duration_PACS.txt Perfect. No differences! 6(f) If Durations are OK then COMMIT the Delivery with CUSGUI OPENED CUSGUI & COMMITTED (REGISTRY/COMMIT) THE PACS DELIVERY In the Comment field, refer to PACS MC P54ASTR as Cal TAKE NOTE : It is very important that you commit the delivery as defined above. Now create the MC in the database hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> missetup -addconfig MC_H49_P54_S56_CAL Jul 6, 2010 4:28:24 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:28:25 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:28:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:28:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:28:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:28:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:28:25 PM herschel.ccm.tools.MissionSetup infoMessage INFO: Using database "hsc_ops_operations_tm_1@herdb02.esac.esa.int" Jul 6, 2010 4:28:26 PM herschel.ccm.tools.MissionSetup infoMessage INFO: Mission configuration "MC_H49_P54_S56_CAL" created in database "hsc_ops_operations_tm_1@herdb02.esac.esa.int" Add the commited CUS to the new MC hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/PACS> Jul 6, 2010 4:28:50 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:28:50 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:28:51 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:28:51 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:28:51 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:28:51 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:28:51 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from PACS, specified by property hcss.cus.instrument Jul 6, 2010 4:29:23 PM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 6, 2010 4:29:40 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:29:40 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:29:40 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:29:40 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:30:03 PM herschel.cus.gui.CusEditor exit INFO: Quitting. Steps to import the new HIFI Instrument model into the MC Set Instrument Model = HIFI Check with CUSGUI Run the duration script for the HIFI instruments Import HIFI into the new Mission Configuration 7(a) Set Instrument Model = HIFI hscphs2@heropl02/home/hscphs2/.hcss> emacs Uplink_Coord.props & #CUS #var.hcss.instrument = SPIRE #var.hcss.instrument = PACS var.hcss.instrument = HIFI hcss.cus.model = FLIGHT Check with CUSGUI hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> Jul 6, 2010 4:31:14 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:31:15 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:31:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:31:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:31:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:31:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:31:15 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from HIFI, specified by property hcss.cus.instrument Jul 6, 2010 4:35:07 PM herschel.cus.gui.CusEditor exit INFO: Quitting. TAKE NOTE : Instrument above must be HIFI if you want to work with the HIFI instrument model. - CONFIRMED!! 7(c) Clean the CUS & Cal tables from the instrument model hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -f -m "clean HIFI CUS from DB" -deleteall Jul 6, 2010 4:35:48 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:35:49 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:35:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:35:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:35:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:35:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:35:58 PM herschel.cus.gui.Cus infoMessage INFO: All definitions have been deleted hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -f -m "clean HIFI CAL from DB" -caldeleteall Jul 6, 2010 4:36:17 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:36:18 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:36:18 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:36:18 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:36:18 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:36:18 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:36:23 PM herschel.cus.gui.Cus infoMessage INFO: All calibration tables successfully deleted TAKE NOTE : OPEN UP CUSGUI & VERIFY IT IS EMPTY i.e. No Cus scripts & No Parameter tables - VERIFIED!!! TAKE NOTE : Check HPSDB in the CUSGUI Session = hpsdb_MOC9_201003161700 - CONFIRMED!! 7(d) Import the new Instrument CUS & Cal tables into the DB Import new Mission Configuration (H49Cal). hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -m "upload HIFI MC49Cal mission config" -import HIFI_MC_R062_FULL_49_0_CUS.def -importcaltables HIFI_MC_R062_FULL_49_0_CUS_CAL.xml Jul 6, 2010 4:37:59 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:38:00 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:38:00 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:38:00 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:38:00 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:38:00 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:38:21 PM herschel.cus.gui.Cus infoMessage INFO: Definitions successfully imported Jul 6, 2010 4:38:21 PM herschel.cus.gui.Cus infoMessage INFO: Using current directory Jul 6, 2010 4:38:22 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:38:22 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:38:22 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:38:22 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:38:30 PM herschel.cus.gui.Cus infoMessage INFO: Calibration tables successfully imported from "HIFI_MC_R062_FULL_49_0_CUS_CAL.xml" TAKE NOTE : The file referred to at the end import message shall correspond to the file that was delivered by HIFI: HIFI_MC_R062_FULL_49_0_CUS_CAL.xml CONFIRMED!! 7(e) Run the duration script for the HIFI instrument Run the duration script delivered hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ./duration_cal.sh HIFI_AOR_C019_49 next AOR file = HIFI_AOR_C019_49 -- mode HifiEngSetIntoPrimary -- mode HifiEng_Stab_COP_freq -- mode HifiEngSwitchonLO -- mode HifiEng_Tsys_COP -- mode HifiMappingModeDBSCross -- mode HifiMappingModeDBSRaster -- mode HifiMappingModeFastDBSCross -- mode HifiMappingModeFastDBSRaster -- mode HifiMappingModeFSwitchOTF -- mode HifiMappingModeFSwitchOTFNoRef -- mode HifiMappingModeLoadChopOTF -- mode HifiMappingModeLoadChopOTFNoRef -- mode HifiMappingModeOTF -- mode HifiSScanModeDBS -- mode HifiSScanModeFastDBS -- mode HifiSScanModeFSwitch -- mode HifiSScanModeFSwitchNoRef -- mode HifiSScanModeLoadChop -- mode HifiSScanModeLoadChopNoRef Total duration of HifiEngSetIntoPrimary with default parameters = 6 Total duration of HifiEng_Stab_COP_freq with default parameters = 3706 Total duration of HifiEngSwitchonLO with default parameters = 395 Total duration of HifiEng_Tsys_COP with default parameters = 1331 Total duration of HifiMappingModeDBSCross with default parameters = 494 Total duration of HifiMappingModeDBSRaster with default parameters = 230 Total duration of HifiMappingModeFastDBSCross with default parameters = 422 Total duration of HifiMappingModeFastDBSRaster with default parameters = 206 Total duration of HifiMappingModeFSwitchOTF with default parameters = 232 Total duration of HifiMappingModeFSwitchOTFNoRef with default parameters = 159 Total duration of HifiMappingModeLoadChopOTF with default parameters = 199 Total duration of HifiMappingModeLoadChopOTFNoRef with default parameters = 126 Total duration of HifiMappingModeOTF with default parameters = 165 Total duration of HifiSScanModeDBS with default parameters = 383 Total duration of HifiSScanModeFastDBS with default parameters = 335 Total duration of HifiSScanModeFSwitch with default parameters = 497 Total duration of HifiSScanModeFSwitchNoRef with default parameters = 414 Total duration of HifiSScanModeLoadChop with default parameters = 347 Total duration of HifiSScanModeLoadChopNoRef with default parameters = 282 hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls -ls total 11320 5652 -rw-r--r-- 1 hscphs2 herschel 5775360 Jul 6 15:32 CYCLE019_HIFI_FULL_1_20100706.tar 4 -rwxr-xr-x 1 hscphs2 herschel 2697 Jul 6 15:21 duration_cal.sh* 172 -rw-r--r-- 1 hscphs2 herschel 168134 Jul 6 15:21 HIFI_AOR_C019_49.aor 4 -rw-r--r-- 1 hscphs2 herschel 1386 Jul 6 15:20 HIFI_DUR_C019_49.txt 2176 -rw-r--r-- 1 hscphs2 herschel 2216733 Jun 21 14:19 HIFI_MC_R062_FULL_49_0_CUS_CAL.xml 3300 -rw-r--r-- 1 hscphs2 herschel 3370001 Jun 21 14:18 HIFI_MC_R062_FULL_49_0_CUS.def 8 -rw-r--r-- 1 hscphs2 herschel 4442 Jul 6 15:24 HIFI_Readme_C019_49.txt 4 -rw-r--r-- 1 hscphs2 herschel 1386 Jul 6 16:42 summary_HIFI_AOR_C019_49.log hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> diff HIFI_DUR_C019_49.txt summary_HIFI_AOR_C019_49.log No differences. Perfect 7(f) If Durations are OK then COMMIT the Delivery with CUSGUI OPENED CUSGUI & COMMITTED (REGISTRY/COMMIT) THE HIFI DELIVERY In the Comment field, refer to HIFI MC H49CAL TAKE NOTE : It is very important that you commit the delivery as defined above. 7(g) Import HIFI into the new Mission Configuration hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> Jul 6, 2010 4:47:40 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:47:41 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:47:41 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:47:41 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:47:41 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:47:41 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:47:42 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from HIFI, specified by property hcss.cus.instrument Jul 6, 2010 4:48:08 PM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 6, 2010 4:48:30 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:48:30 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:48:30 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:48:30 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:49:17 PM herschel.cus.gui.CusEditor exit INFO: Quitting. Steps to Import the Old SPIRE Instrument model into the MC Set Instrument Model = SPIRE Check with CUSGUI Run the duration script for the PACS instrument Import into the new Mission Configuration 8(a) Set Instrument Model = SPIRE #CUS var.hcss.instrument = SPIRE #var.hcss.instrument = PACS #var.hcss.instrument = HIFI hcss.cus.model = FLIGHT Check with CUSGUI hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> Jul 6, 2010 4:50:10 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:50:11 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:50:12 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:50:12 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:50:12 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:50:12 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:50:12 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from SPIRE, specified by property hcss.cus.instrument Jul 6, 2010 4:51:48 PM herschel.cus.gui.CusEditor exit INFO: Quitting. TAKE NOTE : CONFIRM THAT SPIRE IS THE INSTRUMENT MODEL IN THE CUSGUI OUTPUT : CONFIRMED!!!! 8(c) Clean the CUS & Cal tables from the instrument model hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> cus -f -m "clean SPIRE CUS from DB" -deleteall Jul 6, 2010 4:52:14 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:52:14 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:52:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:52:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:52:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:52:15 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:52:26 PM herschel.cus.gui.Cus infoMessage INFO: All definitions have been deleted hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> cus -f -m "clean SPIRE CAL from DB" -caldeleteall Jul 6, 2010 4:53:23 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:53:24 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:53:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:53:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:53:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:53:25 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:53:31 PM herschel.cus.gui.Cus infoMessage INFO: All calibration tables successfully deleted TAKE NOTE : OPEN UP CUSGUI & VERIFY IT IS EMPTY i.e. No Cus scripts & No Parameter tables - VERIFIED!!! TAKE NOTE : Check HPSDB in the CUSGUI Session = hpsdb_MOC9_201003161700 - CONFIRMED!! 8(d) Import the new Instrument CUS & Cal tables into the DB Import old SPIRE Mission Configuration (Version 56.0). hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> cus -m "upload SPIRE MC_56 mission config" -import SPIRE_MC_pv82_C015_56_CUS.def -importcaltables SPIRE_MC_pv82_C015_56_CUS_CAL.xml Jul 6, 2010 4:55:31 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 4:55:32 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 4:55:32 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:55:32 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:55:32 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:55:32 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:55:49 PM herschel.cus.gui.Cus infoMessage INFO: Definitions successfully imported Jul 6, 2010 4:55:49 PM herschel.cus.gui.Cus infoMessage INFO: Using current directory Jul 6, 2010 4:55:49 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:55:49 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 4:55:49 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:55:49 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 4:55:52 PM herschel.cus.gui.Cus infoMessage INFO: Calibration tables successfully imported from "SPIRE_MC_pv82_C015_56_CUS_CAL.xml" TAKE NOTE : The file referred to at the end import message shall correspond to the file that was delivered by SPIRE: SPIRE_MC_pv82_C015_56_CUS_CAL.xml CONFIRMED!! 8(e) Run the duration script for the SPIRE instrument model: hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> python SPIRE_CUS_THCP.py hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> ls -ls total 4696 2340 -rw-r--r-- 1 hscphs2 herschel 2385920 May 20 19:16 CYCLE015_SPIRE_UPDATE_1_1_20100520.tar 4 -rw-r--r-- 1 hscphs2 herschel 3290 May 20 19:05 SPIRE_AOR_C015_56_ENG.aor 4 -rw-r--r-- 1 hscphs2 herschel 1931 Jul 6 16:56 SPIRE_cus_scripts.txt 4 -rw-r--r-- 1 hscphs2 herschel 1174 May 14 17:20 SPIRE_CUS_THCP.py 8 -rw-r--r-- 1 hscphs2 herschel 5147 May 20 19:07 SPIRE_Duration.txt 8 -rw-rw-rw- 1 hscphs2 herschel 5147 May 21 12:06 SPIRE_harness_duration_summary_20100521_12h06m32s.log 8 -rw-rw-rw- 1 hscphs2 herschel 5147 Jul 6 17:00 SPIRE_harness_duration_summary_20100706_17h00m53s.log 276 -rw-r--r-- 1 hscphs2 herschel 276611 May 20 19:06 SPIRE_MC_pv82_C015_56_CUS_CAL.xml 2040 -rw-r--r-- 1 hscphs2 herschel 2083806 May 20 19:06 SPIRE_MC_pv82_C015_56_CUS.def 4 -rw-r--r-- 1 hscphs2 herschel 3437 May 20 19:10 SPIRE_Readme_C015_56.txt hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> diff SPIRE_Duration.txt SPIRE_harness_duration_summary_20100706_17h00m53s.log Perfect. No differences! 8(f) If Durations are OK then COMMIT the Delivery with CUSGUI OPENED CUSGUI & COMMITTED (REGISTRY/COMMIT) THE SPIRE DELIVERY In the Comment field, refer to SPIRE MC S56CAL. TAKE NOTE : It is very important that you commit the delivery as defined above. 8(g) Import SPIRE model into new Mission Configuration hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/SPIRE> Jul 6, 2010 5:03:17 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 5:03:18 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 5:03:19 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:03:19 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:03:19 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 5:03:19 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 5:03:19 PM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from SPIRE, specified by property hcss.cus.instrument Jul 6, 2010 5:03:41 PM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 6, 2010 5:03:53 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:03:53 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:03:53 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 5:03:53 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 5:04:06 PM herschel.cus.gui.CusEditor exit INFO: Quitting. THIS ENDS THE IMPORT OF THE SPIRE INSTRUMENT MODEL INTO THE MISSION CONFIGURATION. 9.Link PropHandler to the new MC & Start PropHandler to confirm Linked Prophandler to the new Mission Config by updating the Uplink_Coord.props file in .hcss directory #Mission Configuration hcss.ccm.mission.config = MC_H49_P54_S56_CAL Source the PHS Environment for 2.3.0_phs hscphs2@heropl02/home/hscphs2/otherSetups> source setHcssEnvironment_v2.3.0_phs hscphs2@heropl02/home/hscphs2/otherSetups> Jul 6, 2010 5:04:48 PM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 6, 2010 5:04:49 PM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 6, 2010 5:04:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:04:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 6, 2010 5:04:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 6, 2010 5:04:50 PM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Running CDH.getObsProgrammes() Jul 6, 2010 5:04:51 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: Loading observation programmes list... Jul 6, 2010 5:04:51 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: CDH: Getting obs progs took: 30 Jul 6, 2010 5:04:51 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: Loading observing modes list... Jul 6, 2010 5:04:51 PM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 6, 2010 5:04:57 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: CDH: Getting obs modes took: 6106 TAKE NOTE : The PropHandler Terminal log above shows that it is correctly pointing to the new Mission Configuration : CONFIRMED!! 10. Export the Hspot Files from PropHandler In PropHandler, select the Calibration pull down menu and export the HSpot files. TAKE NOTE : When the new window opens showing all the properties files, check that you have property files for SPIRE, PACS & HIFI. CONFIRMED!! Select all the files and in the new window that opens, create a new directory in /home/hscphs2/icchsc/HSpot_files/ Called the same as the Mission Confifguration: MC_H49_P54_S56_CAL Exported all the HSpot files to this folder: hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files> mkdir MC_H49_P54_S56_CAL Example of the last entry in the log: Jul 6, 2010 5:07:46 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: Writing calibration prop file:/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL/HifiManCmdSetIntoDissipative_IIGen.prop Jul 6, 2010 5:07:46 PM herschel.phs.prophandler.gui.ProposalHandler message INFO: Writing calibration prop file:/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL/HifiManCmdSetIntoDissipativeGen.prop 11. Do the Check for a new script for Eva Do the following: hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> ls *.prop > & MC_H49_P54_S56_CAL.txt hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> ls -ls *.txt 20 -rw-r--r-- 1 hscphs2 herschel 17610 Jul 6 17:08 MC_H49_P54_S56_CAL.txt hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> cp MC_H49_P54_S56_CAL.txt /home/hscphs2/icchsc/HSpot_files/ Now do a diff between this new txt file and the one generated with the last Mission configuration. hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files> diff MC_H47_P54_S56_CAL.txt MC_H49_P54_S56_CAL.txt If there is a difference inform Eva, Jose of the result. If there is NO difference then no need to inform Eva. Several new HIFI scripts. Do not notify Eva & Jose 12. Final Jboss Activities Log into Jboss #2 herjbo02.esac.esa.int/home/hsc_phs> source .minimal_herjbo02 PHS: Using BUILDNUM 578 PHS: Using JBOSS_HOME /usr/local/software/jboss/jboss-3.2.6_0_6_5 Stop the Test Jboss : herjbo02.esac.esa.int/home/hsc_phs> stopJbossTest set old=/home/hsc_phs chdir /usr/local/software/jboss/jboss-3.2.6_0_6_5/bin if ( -f .keybind ) echo .keybind exists if ( -f .exrc ) echo .exrc exists ./shutdown.sh -s jnp://localhost:1199 Shutdown message has been posted to the server. Server shutdown may take a while - check logfiles for completion Create a directory which contains the name of the new MC : herjbo02.esac.esa.int/home/hsc_phs> mkdir fileHolder_ops_MC_H49_P54_S56_CAL copied HSpot files from the HSpot_files directory on hscphs2 to this directory TAKE NOTE : You should perform this copy from the HSpot files folder on hscphs2. - DONE : SEE BELOW hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> scp *.prop hsc_phs@herjbo02:/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL/ Next update the properties file: herjbo02.esac.esa.int/home/hsc_phs/.hcss> kedit HCSS_PHS_TEST_herjbo02_0_6_6.props & [1] 3171 Update each of the fields below in the Properties file : TAKE NOTE : Double check that this is done correctly!! #MARK TIME ESTIMATOR #hcss.phs.timeEstimatorVersion=MC_H48ASTR_P54ASTR_S55ASTR_RP_100623 #hcss.phs.timeEstimatorVersion=MC_H50ASTR_P54ASTR_S55ASTR_RP_100705 #hcss.phs.timeEstimatorVersion=MC_H47_P54_S56_CAL_100623 hcss.phs.timeEstimatorVersion=MC_H49_P54_S56_CAL_100706 #MARK MISSION CONFIG #hcss.ccm.mission.config = MC_H48ASTR_P54ASTR_S55ASTR_RP #hcss.ccm.mission.config = MC_H50ASTR_P54ASTR_S55ASTR_RP #hcss.ccm.mission.config = MC_H47_P54_S56_CAL hcss.ccm.mission.config = MC_H49_P54_S56_CAL #MARK DIRECTORIES #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H48ASTR_P54ASTR_S55ASTR_RP #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H50ASTR_P54ASTR_S55ASTR_RP #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H47_P54_S56_CAL hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL Finally Restart the Test Jboss. > startJbossTest DONE. LOGOUT OF THE JBOSS MACHINE. YOU ARE FINISHED WITH THIS LOG FILE. --------------------------------------------- Christophe confirms that the delivery was linked to the wrong CUS. Re-delivery HIFI_FULL_1_2 Re-do the following steps to correct Hi Mark, Confirmed, there was a problem in the original delivery. Please disregard that one. The .def and .xml were linked to the wrong cus version, which should be 16.173. I generated the correct MC files and uploaded the tar file in the cvs: CYCLE019_HIFI_FULL_1_2_20100706.tar in - develop/data/observingmodes/rp_cycles/cycle019 Sorry for the problems Cheers, Christophe mkidger@sciops.esa.int wrote: [Hide Quoted Text] Christophe I have just tried to call your office, but I think that you have left already. I seem to have an inconsistency with the durations in your delivery. I noticed that the total duration of the AORs decreases from 17:44:27 to 17:09:39 when I time-estimate with the new MC. Looking at the AORs one by one as they time estimate HifiEng_Tsys_COP_5b_purity_cycle19 decreases to about half the value that I had when I loaded the AORs (4392s --> 2304s), while the other durations remain unchanged. Is this an expected result? Mark 6(a) Download & Untar the delivery from the CVS into the new mission_config directory (& the delivery directory) hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> setenv CVSROOT :pserver:lorourke@cvs.rssd.esa.int:/services/repositories/HERSCHEL_CVS hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> cvs login Logging in to :pserver:lorourke@cvs.rssd.esa.int:2401/services/repositories/HERSCHEL_CVS CVS password: hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> cvs co develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_2_20100706.tar U develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_2_20100706.tar hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> cp develop/data/observingmodes/rp_cycles/cycle019/CYCLE019_HIFI_FULL_1_2_20100706.tar . hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> ls CYCLE019_HIFI_FULL_1_2_20100706.tar develop/ hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> tar -xvf CYCLE019_HIFI_FULL_1_2_20100706.tar HIFI_AOR_C019_49.aor HIFI_DUR_C019_49.txt HIFI_MC_R062_FULL_49_0_CUS_CAL.xml HIFI_MC_R062_FULL_49_0_CUS.def HIFI_Readme_C019_49.txt duration_cal.sh hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> ls CYCLE019_HIFI_FULL_1_2_20100706.tar HIFI_AOR_C019_49.aor HIFI_MC_R062_FULL_49_0_CUS.def develop/ HIFI_DUR_C019_49.txt HIFI_Readme_C019_49.txt duration_cal.sh* HIFI_MC_R062_FULL_49_0_CUS_CAL.xml hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls CYCLE019_HIFI_FULL_1_20100706.tar HIFI_AOR_C019_49.aor HIFI_MC_R062_FULL_49_0_CUS_CAL.xml HIFI_Readme_C019_49.txt duration_cal.sh* HIFI_DUR_C019_49.txt HIFI_MC_R062_FULL_49_0_CUS.def summary_HIFI_AOR_C019_49.log hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> rm * rm: remove regular file `CYCLE019_HIFI_FULL_1_20100706.tar'? y rm: remove regular file `duration_cal.sh'? y rm: remove regular file `HIFI_AOR_C019_49.aor'? y rm: remove regular file `HIFI_DUR_C019_49.txt'? rm: remove regular file `HIFI_MC_R062_FULL_49_0_CUS_CAL.xml'? y rm: remove regular file `HIFI_MC_R062_FULL_49_0_CUS.def'? y rm: remove regular file `HIFI_Readme_C019_49.txt'? y rm: remove regular file `summary_HIFI_AOR_C019_49.log'? y rm: remove regular file `HIFI_DUR_C019_49.txt'? y hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls hscphs2@heropl02/home/hscphs2/icchsc/delivery/Calibration_Cycle19/HIFI/HIFI_FULL_1_2> cp * /home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI/ cp: omitting directory `develop' hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls CYCLE019_HIFI_FULL_1_2_20100706.tar HIFI_AOR_C019_49.aor HIFI_MC_R062_FULL_49_0_CUS_CAL.xml HIFI_Readme_C019_49.txt duration_cal.sh* HIFI_DUR_C019_49.txt HIFI_MC_R062_FULL_49_0_CUS.def 7(a) Set Instrument Model = HIFI hscphs2@heropl02/home/hscphs2/.hcss> emacs Uplink_Coord.props & #CUS #var.hcss.instrument = SPIRE #var.hcss.instrument = PACS var.hcss.instrument = HIFI hcss.cus.model = FLIGHT Check with CUSGUI hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> Jul 7, 2010 9:47:10 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 9:47:11 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 9:47:12 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:47:12 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:47:12 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:47:12 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:47:12 AM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from HIFI, specified by property hcss.cus.instrument Jul 7, 2010 9:47:26 AM herschel.cus.gui.CusEditor exit INFO: Quitting. TAKE NOTE : Instrument above must be HIFI if you want to work with the HIFI instrument model. - CONFIRMED!! 7(c) Clean the CUS & Cal tables from the instrument model hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -f -m "clean HIFI CUS from DB" -deleteall Jul 7, 2010 9:47:50 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 9:47:51 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 9:47:52 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:47:52 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:47:52 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:47:52 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:48:09 AM herschel.cus.gui.Cus infoMessage INFO: All definitions have been deleted hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -f -m "clean HIFI CAL from DB" -caldeleteall Jul 7, 2010 9:48:56 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 9:48:57 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 9:48:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:48:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:48:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:48:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:49:04 AM herschel.cus.gui.Cus infoMessage INFO: All calibration tables successfully deleted TAKE NOTE : OPEN UP CUSGUI & VERIFY IT IS EMPTY i.e. No Cus scripts & No Parameter tables - VERIFIED!!! TAKE NOTE : Check HPSDB in the CUSGUI Session = hpsdb_MOC9_201003161700 - CONFIRMED!! 7(d) Import the new Instrument CUS & Cal tables into the DB Import new Mission Configuration (H49Cal). hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> cus -m "upload HIFI MC49Cal mission config" -import HIFI_MC_R062_FULL_49_0_CUS.def -importcaltables HIFI_MC_R062_FULL_49_0_CUS_CAL.xml Jul 7, 2010 9:50:08 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 9:50:09 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 9:50:30 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:50:30 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:50:30 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:50:30 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:50:53 AM herschel.cus.gui.Cus infoMessage INFO: Definitions successfully imported Jul 7, 2010 9:50:53 AM herschel.cus.gui.Cus infoMessage INFO: Using current directory Jul 7, 2010 9:50:53 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:50:53 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 9:50:53 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:50:53 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 9:51:11 AM herschel.cus.gui.Cus infoMessage INFO: Calibration tables successfully imported from "HIFI_MC_R062_FULL_49_0_CUS_CAL.xml" TAKE NOTE : The file referred to at the end import message shall correspond to the file that was delivered by HIFI: HIFI_MC_R062_FULL_49_0_CUS_CAL.xml CONFIRMED!! 7(e) Run the duration script for the HIFI instrument Run the duration script delivered hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ./duration_cal.sh HIFI_AOR_C019_49 next AOR file = HIFI_AOR_C019_49 -- mode HifiEngSetIntoPrimary -- mode HifiEng_Stab_COP_freq -- mode HifiEngSwitchonLO -- mode HifiEng_Tsys_COP -- mode HifiMappingModeDBSCross -- mode HifiMappingModeDBSRaster -- mode HifiMappingModeFastDBSCross -- mode HifiMappingModeFastDBSRaster -- mode HifiMappingModeFSwitchOTF -- mode HifiMappingModeFSwitchOTFNoRef -- mode HifiMappingModeLoadChopOTF -- mode HifiMappingModeLoadChopOTFNoRef -- mode HifiMappingModeOTF -- mode HifiSScanModeDBS -- mode HifiSScanModeFastDBS -- mode HifiSScanModeFSwitch -- mode HifiSScanModeFSwitchNoRef -- mode HifiSScanModeLoadChop -- mode HifiSScanModeLoadChopNoRef Total duration of HifiEngSetIntoPrimary with default parameters = 6 Total duration of HifiEng_Stab_COP_freq with default parameters = 3706 Total duration of HifiEngSwitchonLO with default parameters = 395 Total duration of HifiEng_Tsys_COP with default parameters = 1331 Total duration of HifiMappingModeDBSCross with default parameters = 494 Total duration of HifiMappingModeDBSRaster with default parameters = 230 Total duration of HifiMappingModeFastDBSCross with default parameters = 422 Total duration of HifiMappingModeFastDBSRaster with default parameters = 206 Total duration of HifiMappingModeFSwitchOTF with default parameters = 232 Total duration of HifiMappingModeFSwitchOTFNoRef with default parameters = 159 Total duration of HifiMappingModeLoadChopOTF with default parameters = 199 Total duration of HifiMappingModeLoadChopOTFNoRef with default parameters = 126 Total duration of HifiMappingModeOTF with default parameters = 165 Total duration of HifiSScanModeDBS with default parameters = 383 Total duration of HifiSScanModeFastDBS with default parameters = 335 Total duration of HifiSScanModeFSwitch with default parameters = 497 Total duration of HifiSScanModeFSwitchNoRef with default parameters = 414 Total duration of HifiSScanModeLoadChop with default parameters = 347 Total duration of HifiSScanModeLoadChopNoRef with default parameters = 282 hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> ls -ls total 11304 5644 -rw-r--r-- 1 hscphs2 herschel 5765120 Jul 6 18:20 CYCLE019_HIFI_FULL_1_2_20100706.tar 4 -rwxr-xr-x 1 hscphs2 herschel 2697 Jul 6 15:21 duration_cal.sh* 172 -rw-r--r-- 1 hscphs2 herschel 168134 Jul 6 15:21 HIFI_AOR_C019_49.aor 4 -rw-r--r-- 1 hscphs2 herschel 1386 Jul 6 15:20 HIFI_DUR_C019_49.txt 2168 -rw-r--r-- 1 hscphs2 herschel 2210147 Jul 6 18:16 HIFI_MC_R062_FULL_49_0_CUS_CAL.xml 3300 -rw-r--r-- 1 hscphs2 herschel 3370609 Jul 6 18:16 HIFI_MC_R062_FULL_49_0_CUS.def 8 -rw-r--r-- 1 hscphs2 herschel 4442 Jul 6 15:24 HIFI_Readme_C019_49.txt 4 -rw-r--r-- 1 hscphs2 herschel 1386 Jul 7 09:53 summary_HIFI_AOR_C019_49.log hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> diff HIFI_DUR_C019_49.txt summary_HIFI_AOR_C019_49.log No differences. Perfect 7(f) If Durations are OK then COMMIT the Delivery with CUSGUI OPENED CUSGUI & COMMITTED (REGISTRY/COMMIT) THE HIFI DELIVERY In the Comment field, refer to HIFI MC H49CAL TAKE NOTE : It is very important that you commit the delivery as defined above. 7(g) Import HIFI into the new Mission Configuration hscphs2@heropl02/home/hscphs2/icchsc/mission_config/MC_H49_P54_S56_CAL/HIFI> Jul 7, 2010 10:06:44 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 10:06:45 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 10:06:45 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:06:45 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:06:46 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 10:06:46 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 10:06:46 AM herschel.cus.gui.CusEditor chooseInstrument INFO: Using instrument command set from HIFI, specified by property hcss.cus.instrument Jul 7, 2010 10:07:18 AM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 7, 2010 10:07:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:07:57 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:07:58 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 10:07:58 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 10:08:32 AM herschel.cus.gui.CusEditor exit INFO: Quitting. 9.Link PropHandler to the new MC & Start PropHandler to confirm Linked Prophandler to the new Mission Config by updating the Uplink_Coord.props file in .hcss directory #Mission Configuration hcss.ccm.mission.config = MC_H49_P54_S56_CAL Source the PHS Environment for 5.0.5_phs hscphs2@heropl02/home/hscphs2/otherSetups> source setHcssEnvironment_v5.0.5_phs hscphs2@heropl02/home/hscphs2/otherSetups> propHandler & hscphs2@heropl02/home/hscphs2/otherSetups> Jul 7, 2010 10:29:33 AM herschel.share.log.util.LogInitialiser init INFO: Initialising using local log configuation file /home/hscphs2/.hcss/userlogging.properties Jul 7, 2010 10:29:34 AM herschel.versant.store.ReplStoreFactoryImpl createStore INFO: Creating ObjectStore: hsc_ops_operations_tm_1@herdb02.esac.esa.int Jul 7, 2010 10:29:35 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RO-Access for node: hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:29:35 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n2@herdb02.esac.esa.int Jul 7, 2010 10:29:35 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Using RW-Access for node: hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Jul 7, 2010 10:29:35 AM herschel.versant.store.replication.ReplicatingTransaction connectToRemoteDatabase INFO: Connection established to hsc_ops_operations_tm_1_n3@herdb02.esac.esa.int Running CDH.getObsProgrammes() Jul 7, 2010 10:29:36 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: Loading observation programmes list... Jul 7, 2010 10:29:36 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: CDH: Getting obs progs took: 32 Jul 7, 2010 10:29:36 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: Loading observing modes list... Jul 7, 2010 10:29:36 AM herschel.versant.ccm.MissionImpl getMissionConfiguration INFO: Using configuration "MC_H49_P54_S56_CAL" Jul 7, 2010 10:29:42 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: CDH: Getting obs modes took: 6042 TAKE NOTE : The PropHandler Terminal log above shows that it is correctly pointing to the new Mission Configuration : CONFIRMED!! 10. Export the Hspot Files from PropHandler In PropHandler, select the Calibration pull down menu and export the HSpot files. TAKE NOTE : When the new window opens showing all the properties files, check that you have property files for SPIRE, PACS & HIFI. CONFIRMED!! Select all the files and in the new window that opens, create a new directory in /home/hscphs2/icchsc/HSpot_files/ Called the same as the Mission Confifguration: MC_H49_P54_S56_CAL Clean directory of old .prop files hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> rm -f * hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> ls Exported all the HSpot files to this folder: hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files> mkdir MC_H49_P54_S56_CAL Example of the last entry in the log: Jul 7, 2010 10:38:29 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: Writing calibration prop file:/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL/HifiManCmdSetIntoDissipative_IIGen.prop Jul 7, 2010 10:38:29 AM herschel.phs.prophandler.gui.ProposalHandler message INFO: Writing calibration prop file:/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL/HifiManCmdSetIntoDissipativeGen.prop 11. Do the Check for a new script for Eva Do the following: hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> ls *.prop > & MC_H49_P54_S56_CAL.txt hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> ls -ls *.txt 20 -rw-r--r-- 1 hscphs2 herschel 17610 Jul 7 10:41 MC_H49_P54_S56_CAL.txt hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> cp MC_H49_P54_S56_CAL.txt /home/hscphs2/icchsc/HSpot_files/ Now do a diff between this new txt file and the one generated with the last Mission configuration. hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files> diff MC_H47_P54_S56_CAL.txt MC_H49_P54_S56_CAL.txt If there is a difference inform Eva, Jose of the result. If there is NO difference then no need to inform Eva. Several new HIFI scripts. Do not notify Eva & Jose 12. Final Jboss Activities Log into Jboss #2 herjbo02.esac.esa.int/home/hsc_phs> source .minimal_herjbo02 PHS: Using BUILDNUM 578 PHS: Using JBOSS_HOME /usr/local/software/jboss/jboss-3.2.6_0_6_5 Stop the Test Jboss : herjbo02.esac.esa.int/home/hsc_phs> stopJbossTest set old=/home/hsc_phs chdir /usr/local/software/jboss/jboss-3.2.6_0_6_5/bin if ( -f .keybind ) echo .keybind exists if ( -f .exrc ) echo .exrc exists ./shutdown.sh -s jnp://localhost:1199 Shutdown message has been posted to the server. Server shutdown may take a while - check logfiles for completion Create a directory which contains the name of the new MC : herjbo02.esac.esa.int/home/hsc_phs> mkdir fileHolder_ops_MC_H49_P54_S56_CAL Clean bad .prop files herjbo02.esac.esa.int/home/hsc_phs> cd fileHolder_ops_MC_H49_P54_S56_CAL herjbo02.esac.esa.int/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL> rm -f * herjbo02.esac.esa.int/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL> ls herjbo02.esac.esa.int/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL> cd .. copied HSpot files from the HSpot_files directory on hscphs2 to this directory TAKE NOTE : You should perform this copy from the HSpot files folder on hscphs2. - DONE : SEE BELOW hscphs2@heropl02/home/hscphs2/icchsc/HSpot_files/MC_H49_P54_S56_CAL> scp *.prop hsc_phs@herjbo02:/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL/ Next update the properties file: herjbo02.esac.esa.int/home/hsc_phs/.hcss> kedit HCSS_PHS_TEST_herjbo02_0_6_6.props & [1] 3171 Update each of the fields below in the Properties file : TAKE NOTE : Double check that this is done correctly!! #MARK TIME ESTIMATOR #hcss.phs.timeEstimatorVersion=MC_H48ASTR_P54ASTR_S55ASTR_RP_100623 #hcss.phs.timeEstimatorVersion=MC_H50ASTR_P54ASTR_S55ASTR_RP_100705 #hcss.phs.timeEstimatorVersion=MC_H47_P54_S56_CAL_100623 hcss.phs.timeEstimatorVersion=MC_H49_P54_S56_CAL_100707 #MARK MISSION CONFIG #hcss.ccm.mission.config = MC_H48ASTR_P54ASTR_S55ASTR_RP #hcss.ccm.mission.config = MC_H50ASTR_P54ASTR_S55ASTR_RP #hcss.ccm.mission.config = MC_H47_P54_S56_CAL hcss.ccm.mission.config = MC_H49_P54_S56_CAL #MARK DIRECTORIES #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H48ASTR_P54ASTR_S55ASTR_RP #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H50ASTR_P54ASTR_S55ASTR_RP #hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H47_P54_S56_CAL hcss.phs.fileHolder=/home/hsc_phs/fileHolder_ops_MC_H49_P54_S56_CAL Finally Restart the Test Jboss. > startJbossTest DONE. LOGOUT OF THE JBOSS MACHINE. YOU ARE FINISHED WITH THIS LOG FILE.