From: Lionel Duband [duband@drfmc.ceng.cea.fr]
Sent: 30
March 2001 13:29
To: K.J.King@rl.ac.uk; AUGUERES@dapnia.cea.fr;
b.m.swinyard@rl.ac.uk; rodriguez@hep.saclay.cea.fr; J.A.Long@rl.ac.uk;
rlclerc@drfmc.ceng.cea.fr; miquet@drfmc.ceng.cea.fr; vallcor@drfmc.ceng.cea.fr;
dguillau@drfmc.ceng.cea.fr; pdupont@drfmc.ceng.cea.fr
Subject:
HSO/SPIRE&PACS/Sorption Coolers - March 2001 Progress Report
SPIRE-SBT-REP-000779
HSO - SPIRE & PACS Sorption Coolers - March 2001 Progress
Report
Bonjour,
GENERAL
- A first set of the detailed drawings of the cooler has been received for
comments (drawings numbering, names, etc....). The full corrected set
should be available within one week.
- The cooler DDR is expected to be held in Grenoble, begining of May. SPIRE
Project will submit a list of potential attendees.
- Reliability analysis (FMECA) : Document is being reworked by LGM
Consultant.
- Quality assurance : quality system in progress - The format of the
documents has been changed (see list below - not completed yet). Many documents
to be issued - First list :
* SPIRE & PACS Sorption Coolers - Manufacturing, Assembly, Integration
and Verification Flow Chart (MAIV) : almost done.
* SPIRE & PACS Sorption Coolers - Interface Control Document (ICD):
soon.
* SPIRE & PACS Sorption Coolers - Verification and Test Plan : partly
done
* SPIRE & PACS Sorption Coolers - PA Plan : soon
* SPIRE & PACS Sorption Coolers - Declared Material List and Declared
Processes List (DML, DPL) : 50% done
* SPIRE & PACS Sorption Coolers - Configuration Item Data List (CIDL) :
soon
* SPIRE & PACS Sorption Coolers - Drawing List : done
* SPIRE & PACS Sorption Coolers - Non Conformance Control Procedure :
50% done
* SPIRE & PACS Sorption Coolers - Architectural Analysis Report :
soon
* SPIRE & PACS Sorption Coolers - FMECA Report : soon
* SPIRE & PACS Sorption Coolers - Sorption Cooler User's Manual : in
the future
COOLER DESIGN
- Done
- Numerical modeling of the overal cooler still in progress
ACTIONS LIST
- None
VARIOUS
- N/A
---------------------------------------
DOCUMENTS STATUS
These are the documents which were written specifically for
SPIRE/PACS.
* CEA-SBT
* Title : "SPIRE & PACS SORPTION COOLERS, DEVELOPMENT PLAN"
HSO-SBT-PL-002 Issue : 2 - Revision : 2
modification :
reformatted
* Title : "SPIRE & PACS SORPTION COOLERS, SPECIFICATIONS"
HSO-SBT-PL-001 Issue : 2 - Revision : 6
modification :
reformatted
TECHNICAL NOTES SERIES
* Title : "THERMAL COUPLING OF THE SORPTION PUMP TO THE COLD HEAT SINK.
HEAT SWITCH VERSUS PASSIVE LINK"
TNS1 Issue : 1 - Revision : 1
modification :
none
* Title : "DISCUSSION ON 4 LITERS VERSUS 6 LITERS UNIT & ULTIMATE
TEMPERATURE IMPROVEMENT"
TNS2 Issue : 1 - Revision : 0
modification :
none
* Title : "TEMPERATURE REGULATION"
TNS3 Issue : 0 - Revision : 0
modification :
none
* MSSL + CEA-SBT
* Title : "ICD 1.1/1.3 STRUCTURE/COOLER"
SPIRE-MSS-PRJ-000331 Issue : 0 - Revision : 2
modification :
none
Best Regards
Lionel Duband
--
--------------------------------------------------------------------------
Lionel
Duband
CEA -
Grenoble
Cryocoolers and space cryogenics
Service des
Basses Temperatures
Voice: (33) (0)4 76 88 41
34
17 av. des
Martyrs
Fax: (33) (0)4 76 88 51 71
38054 Grenoble
Cedex 9 FRANCE
E-mail: duband@drfmc.ceng.cea.fr
"Work for the future.
That is where you are going to spend the rest of your
life."