HSO - SPIRE & PACS Sorption Coolers - March 2001 Progress Report

Bonjour,


GENERAL

- A first set of the detailed drawings of the cooler has been received for comments (drawings numbering, names, etc....).  The full corrected set should be available within one week.

- The cooler DDR is expected to be held in Grenoble, begining of May. SPIRE Project will submit a list of potential attendees.


- Reliability analysis (FMECA) : Document is being reworked by LGM Consultant.
- Quality assurance : quality system in progress - The format of the documents has been changed (see list below - not completed yet). Many documents to be issued - First list :

* SPIRE & PACS Sorption Coolers - Manufacturing, Assembly, Integration and Verification Flow Chart (MAIV) : almost done.
* SPIRE & PACS Sorption Coolers - Interface Control Document (ICD): soon.
* SPIRE & PACS Sorption Coolers - Verification and Test Plan : partly done
* SPIRE & PACS Sorption Coolers - PA Plan : soon
* SPIRE & PACS Sorption Coolers - Declared Material List and Declared Processes List (DML, DPL) : 50% done
* SPIRE & PACS Sorption Coolers - Configuration Item Data List (CIDL) : soon
* SPIRE & PACS Sorption Coolers - Drawing List : done
* SPIRE & PACS Sorption Coolers - Non Conformance Control Procedure : 50% done
* SPIRE & PACS Sorption Coolers - Architectural Analysis Report : soon
* SPIRE & PACS Sorption Coolers - FMECA Report : soon
* SPIRE & PACS Sorption Coolers - Sorption Cooler User's Manual : in the future



COOLER DESIGN

- Done

- Numerical modeling of the overal cooler still in progress



ACTIONS LIST

- None

VARIOUS

- N/A


---------------------------------------
DOCUMENTS STATUS

These are the documents which were written specifically for SPIRE/PACS.

* CEA-SBT

* Title : "SPIRE & PACS SORPTION COOLERS,  DEVELOPMENT PLAN"
HSO-SBT-PL-002      Issue : 2 - Revision : 2
        modification : reformatted

* Title : "SPIRE & PACS SORPTION COOLERS, SPECIFICATIONS"
HSO-SBT-PL-001    Issue : 2 - Revision : 6
        modification : reformatted

TECHNICAL NOTES SERIES

* Title : "THERMAL COUPLING OF THE SORPTION PUMP TO THE COLD HEAT SINK. HEAT SWITCH VERSUS PASSIVE LINK"
TNS1    Issue : 1 - Revision : 1
        modification : none


* Title : "DISCUSSION ON 4 LITERS VERSUS 6 LITERS UNIT & ULTIMATE TEMPERATURE IMPROVEMENT"
TNS2    Issue : 1 - Revision : 0
        modification : none


* Title : "TEMPERATURE REGULATION"
TNS3    Issue : 0 - Revision : 0
        modification : none


* MSSL + CEA-SBT

* Title : "ICD 1.1/1.3 STRUCTURE/COOLER"
SPIRE-MSS-PRJ-000331    Issue : 0 - Revision : 2
        modification : none



Best Regards
Lionel Duband
--

--------------------------------------------------------------------------
Lionel Duband                      CEA - Grenoble
Cryocoolers and space cryogenics          Service des Basses Temperatures
Voice: (33) (0)4 76 88 41 34             17 av. des Martyrs
Fax: (33) (0)4 76 88 51 71            38054 Grenoble Cedex 9 FRANCE
E-mail: duband@drfmc.ceng.cea.fr

"Work for the future. That is where you are going to spend the rest of your
life."  
                                                       -- Mark Twain