Observation Summary

OBSID:1342239688
Instrument:PACS
AOR label:PSpecR-OI-ESO138-G027
Proposal:OT1_larmus_1
Target:ESO138-G027
Actual RA:17h 26m 43.24s
Actual Dec.:-59° 55' 54.41''
Purpose:offSelector
Concat.:1342239687,1342239688
OD:1020
Start:2012-02-27T15:30:30.000000 TAI (1709047830000000)
Duration:888.0 seconds (incl. spacecraft on-target slew time)

AOT and instrument configuration:

AOT:PacsRangeSpec
Mode:Pointed, Chop/Nod
Bands:B3A R1 (prime diffraction orders selected)
Sampling:High (default spectral mapping)
Chopper:small throw
Nod cycles:1

Observation block summary

Name(*)CameraIDBand(*)ReqWaveMin(*)ReqWaveMax(*)WaveMinWaveMaxRepetitions(*)ActualRepCapacitanceOutOfBandChannel
micrometermicrometermicrometermicrometerpF
OI63blue2B3A64.22064.78064.12164.901110.14Noprime
-red102R1--192.335194.684110.14Noparallel
(*) = requested in HSPOT

System configuration summary

SPG pipeline version:SPG v14.2.0
SPG pipeline products creation date:2016-07-26T21:47:48.017000 TAI (1848260868017000)
Mission configuration:MC_H98ASTR_P69ASTR_S66ASTR_RP
Processed to level:RED: 1.0 BLUE: 2.0
Quality Control:PASSED
Action:NONE

Quality comments

Red data did not process to Level 2 as the spectral range falls out of the band. Blue data processed correctly


WARNING: The red channel was processed up to level 1.0, while the blue channel was processed up to level 2.0. See above quality summary for more information (if available)