Observation Summary

OBSID:1342234260
Instrument:PACS
AOR label:PSpecR-OI-NGC7592
Proposal:OT1_larmus_1
Target:NGC7592
Actual RA:23h 18m 22.06s
Actual Dec.:-4° 24' 57.35''
Purpose:offSelector
Concat.:1342234259,1342234260
OD:936
Start:2011-12-06T00:38:09.000000 TAI (1701823089000000)
Duration:896.0 seconds (incl. spacecraft on-target slew time)

AOT and instrument configuration:

AOT:PacsRangeSpec
Mode:Pointed, Chop/Nod
Bands:B3A R1 (prime diffraction orders selected)
Sampling:High (default spectral mapping)
Chopper:small throw
Nod cycles:1

Observation block summary

Name(*)CameraIDBand(*)ReqWaveMin(*)ReqWaveMax(*)WaveMinWaveMaxRepetitions(*)ActualRepCapacitanceOutOfBandChannel
micrometermicrometermicrometermicrometerpF
OI63blue2B3A64.45065.01064.34065.121110.14Noprime
-red102R1--192.994195.340110.14Noparallel
(*) = requested in HSPOT

System configuration summary

SPG pipeline version:SPG v14.2.0
SPG pipeline products creation date:2016-07-26T10:52:52.684000 TAI (1848221572684000)
Mission configuration:MC_H90ASTR_P67ASTR_S63ASTR_HPSDB_MOC13
Processed to level:RED: 1.0 BLUE: 2.0
Quality Control:PASSED
Action:NONE

Quality comments

Red data did not process to Level 2 as the spectral range falls out of the band. Blue data processed correctly


WARNING: The red channel was processed up to level 1.0, while the blue channel was processed up to level 2.0. See above quality summary for more information (if available)