Observation Summary

OBSID:1342228234
Instrument:PACS
AOR label:Bright 1 - HOPS 210 - 8574279-0863483
Proposal:KPOT_tmegeath_2
Target:8574279-0863483
Actual RA:5h 42m 58.32s
Actual Dec.:-8° 38' 5.63''
Purpose:offSelector
Concat.:1342228234,1342228235
OD:846
Start:2011-09-06T15:28:35.000000 TAI (1694014115000000)
Duration:5204.0 seconds (incl. spacecraft on-target slew time)

AOT and instrument configuration:

AOT:PacsRangeSpec
Mode:Pointed, Chop/Nod
Bands:B3A R1 (prime diffraction orders selected)
Sampling:Nyquist (with spectral dithering if range repetition > 1)
Chopper:large throw
Nod cycles:1

Observation block summary

Name(*)CameraIDBand(*)ReqWaveMin(*)ReqWaveMax(*)WaveMinWaveMaxRepetitions(*)ActualRepCapacitanceOutOfBandChannel
micrometermicrometermicrometermicrometerpF
Range 1blue2B2A,B3A57.00071.00050.57071.263210.14Yes, partlyprime
-red102R1--170.472213.191210.14Noparallel
Range 2red103R1102.000142.000101.309142.516210.14Noprime
-blue3B2A--50.57071.263210.14Yes, partlyparallel
(*) = requested in HSPOT

System configuration summary

SPG pipeline version:SPG v14.2.0
SPG pipeline products creation date:2016-07-26T01:00:37.119000 TAI (1848186037119000)
Mission configuration:MC_H88ASTR_P67ASTR_S63ASTR_RP
Processed to level:RED: 2.0 BLUE: 2.0
Quality Control:PASSED
Action:NONE

Quality comments

Due to an instrument anomaly the grating movement was inhibited during the first repetition of a range.
The data have been pipeline processed correctly, but the SNR will be lower than expected due to the fewer repeats on the spectral range than requested.