Observation Summary
OBSID: | 1342207780 |
Instrument: | PACS |
AOR label: | PACS Ser SMM1 - 102-120 |
Proposal: | KPGT_evandish_1 |
Target: | Ser SMM1 |
Actual RA: | 18h 29m 49.7s |
Actual Dec.: | 1° 15' 20.41'' |
Purpose: | Undefined |
Concat.: | --- |
OD: | 535 |
Start: | 2010-10-31T11:39:27.000000 TAI (1667216367000000) |
Duration: | 6280.0 seconds (incl. spacecraft on-target slew time) |
AOT and instrument configuration:
AOT: | PacsRangeSpec |
Mode: | Pointed, Chop/Nod |
Bands: | B2B R1 (prime diffraction orders selected) |
Sampling: | Nyquist (with spectral dithering if range repetition > 1) |
Chopper: | large throw |
Nod cycles: | 1 |
Observation block summary
Name(*) | Camera | ID | Band(*) | ReqWaveMin(*) | ReqWaveMax(*) | WaveMin | WaveMax | Repetitions(*) | ActualRep | Capacitance | OutOfBand | Channel |
| | | | micrometer | micrometer | micrometer | micrometer | | | pF | | |
Range 1 | red | 105 | R1 | 102.000 | 120.000 | 101.303 | 140.229 | 2 | 1 | 0.45 | No | prime |
- | blue | 5 | B2B | - | - | 50.634 | 60.314 | 2 | - | - | Yes, fully | parallel |
Range 2 | red | 104 | R1 | 119.000 | 140.000 | 101.303 | 175.232 | 2 | 1 | 0.45 | No | prime |
- | blue | 4 | B2B | - | - | 59.175 | 70.130 | 2 | 1 | 0.24 | Yes, partly | parallel |
Range 3 | red | 103 | R1 | 139.000 | 175.000 | 118.349 | 210.350 | 2 | 1 | 0.45 | No | prime |
- | blue | 3 | B2B | - | - | 69.211 | 87.628 | 2 | 1 | 0.24 | No | parallel |
Range 4 | red | 102 | R1 | 174.000 | 210.000 | 138.389 | 210.350 | 2 | 1 | 0.45 | No | prime |
- | blue | 2 | B2B | - | - | 86.752 | 105.221 | 2 | 1 | 0.24 | Yes, partly | parallel |
(*) = requested in HSPOT
System configuration summary
SPG pipeline version: | SPG v14.2.0 |
SPG pipeline products creation date: | 2016-07-24T07:17:18.911000 TAI (1848035838911000) |
Mission configuration: | MC_H58ASTR_P55ASTR_S60ASTR_RP |
Processed to level: | RED: 2.0 BLUE: 2.0 |
Quality Control: | PASSED |
Action: | NONE |
Quality comments
Due to an instrument anomaly the grating movement was inhibited during the first repetition of a range.
The data have been pipeline processed correctly, but the SNR will be lower than expected due to the fewer repeats on the spectral range than requested.